{"title":"开发用于皮肤电子治疗总剂量评估的 3D 打印模型","authors":"Andrew Lee, Zaid Alkhatib, Mounir Ibrahim, Broderick McCallum-Hee, Joshua Dass, Matthew Fernandez de Viana, Pejman Rowshanfarzad","doi":"10.1002/acm2.14520","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>Total skin electron therapy (TSET) is a complex radiotherapy technique, posing challenges in commissioning and quality assurance (QA), especially due to significant variability in patient body shapes. Previous studies have correlated dose with factors such as obesity index, height, and gender. However, current treatment planning systems cannot simulate TSET plans, necessitating heavy reliance on QA methods using standardized anthropomorphic phantoms and in-vivo dosimetry. Given the relatively few studies on rotational techniques, comprehensive data in commissioning could streamline the process.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Developing a full-body phantom would enable a more thorough TSET commissioning process, including testing for position-specific dose distributions and comprehensive measurements across all body surfaces, unlike the typical torso-only phantoms. This was created using digital modeling software, fabricated using 3D-printing FDM technology, and filled with tissue-equivalent gelatine. The phantom was positioned at an SSD of 340 cm and irradiated with a standard rotational TSET plan using the 6E HDTSE mode on a Varian TrueBeam linac at gantry angles of ± 18° from the horizontal. The dose was measured at over 50 points across the surface using Gafchromic EBT3 film.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Dose distributions were generally consistent with existing literature values from in-vivo dosimetry, with several position-specific differences identified, including the hands and scalp compared to conventional positions. Hotspots were observed for the mid-dorsum of the foot and nose, with areas under 80% of the dose identified as the soles of the feet, perineum, vertex of the scalp, top of the shoulder, and palm of the hand. Additionally, analysis using an interpolated dose heatmap found that 90% of the pixel area received a dose within 10% of the prescribed dose, indicating good uniformity with the commissioned technique.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>With high agreement with the current literature, a 3D-printed phantom proves effective for measuring doses in areas typically unmeasurable in TSET commissioning.</p>\n </section>\n </div>","PeriodicalId":14989,"journal":{"name":"Journal of Applied Clinical Medical Physics","volume":"25 12","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/acm2.14520","citationCount":"0","resultStr":"{\"title\":\"Development of a 3D-printed phantom for total skin electron therapy dose assessment\",\"authors\":\"Andrew Lee, Zaid Alkhatib, Mounir Ibrahim, Broderick McCallum-Hee, Joshua Dass, Matthew Fernandez de Viana, Pejman Rowshanfarzad\",\"doi\":\"10.1002/acm2.14520\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Purpose</h3>\\n \\n <p>Total skin electron therapy (TSET) is a complex radiotherapy technique, posing challenges in commissioning and quality assurance (QA), especially due to significant variability in patient body shapes. Previous studies have correlated dose with factors such as obesity index, height, and gender. However, current treatment planning systems cannot simulate TSET plans, necessitating heavy reliance on QA methods using standardized anthropomorphic phantoms and in-vivo dosimetry. Given the relatively few studies on rotational techniques, comprehensive data in commissioning could streamline the process.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>Developing a full-body phantom would enable a more thorough TSET commissioning process, including testing for position-specific dose distributions and comprehensive measurements across all body surfaces, unlike the typical torso-only phantoms. This was created using digital modeling software, fabricated using 3D-printing FDM technology, and filled with tissue-equivalent gelatine. The phantom was positioned at an SSD of 340 cm and irradiated with a standard rotational TSET plan using the 6E HDTSE mode on a Varian TrueBeam linac at gantry angles of ± 18° from the horizontal. The dose was measured at over 50 points across the surface using Gafchromic EBT3 film.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Dose distributions were generally consistent with existing literature values from in-vivo dosimetry, with several position-specific differences identified, including the hands and scalp compared to conventional positions. Hotspots were observed for the mid-dorsum of the foot and nose, with areas under 80% of the dose identified as the soles of the feet, perineum, vertex of the scalp, top of the shoulder, and palm of the hand. Additionally, analysis using an interpolated dose heatmap found that 90% of the pixel area received a dose within 10% of the prescribed dose, indicating good uniformity with the commissioned technique.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>With high agreement with the current literature, a 3D-printed phantom proves effective for measuring doses in areas typically unmeasurable in TSET commissioning.</p>\\n </section>\\n </div>\",\"PeriodicalId\":14989,\"journal\":{\"name\":\"Journal of Applied Clinical Medical Physics\",\"volume\":\"25 12\",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-09-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/acm2.14520\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Clinical Medical Physics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/acm2.14520\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Clinical Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/acm2.14520","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Development of a 3D-printed phantom for total skin electron therapy dose assessment
Purpose
Total skin electron therapy (TSET) is a complex radiotherapy technique, posing challenges in commissioning and quality assurance (QA), especially due to significant variability in patient body shapes. Previous studies have correlated dose with factors such as obesity index, height, and gender. However, current treatment planning systems cannot simulate TSET plans, necessitating heavy reliance on QA methods using standardized anthropomorphic phantoms and in-vivo dosimetry. Given the relatively few studies on rotational techniques, comprehensive data in commissioning could streamline the process.
Methods
Developing a full-body phantom would enable a more thorough TSET commissioning process, including testing for position-specific dose distributions and comprehensive measurements across all body surfaces, unlike the typical torso-only phantoms. This was created using digital modeling software, fabricated using 3D-printing FDM technology, and filled with tissue-equivalent gelatine. The phantom was positioned at an SSD of 340 cm and irradiated with a standard rotational TSET plan using the 6E HDTSE mode on a Varian TrueBeam linac at gantry angles of ± 18° from the horizontal. The dose was measured at over 50 points across the surface using Gafchromic EBT3 film.
Results
Dose distributions were generally consistent with existing literature values from in-vivo dosimetry, with several position-specific differences identified, including the hands and scalp compared to conventional positions. Hotspots were observed for the mid-dorsum of the foot and nose, with areas under 80% of the dose identified as the soles of the feet, perineum, vertex of the scalp, top of the shoulder, and palm of the hand. Additionally, analysis using an interpolated dose heatmap found that 90% of the pixel area received a dose within 10% of the prescribed dose, indicating good uniformity with the commissioned technique.
Conclusions
With high agreement with the current literature, a 3D-printed phantom proves effective for measuring doses in areas typically unmeasurable in TSET commissioning.
期刊介绍:
Journal of Applied Clinical Medical Physics is an international Open Access publication dedicated to clinical medical physics. JACMP welcomes original contributions dealing with all aspects of medical physics from scientists working in the clinical medical physics around the world. JACMP accepts only online submission.
JACMP will publish:
-Original Contributions: Peer-reviewed, investigations that represent new and significant contributions to the field. Recommended word count: up to 7500.
-Review Articles: Reviews of major areas or sub-areas in the field of clinical medical physics. These articles may be of any length and are peer reviewed.
-Technical Notes: These should be no longer than 3000 words, including key references.
-Letters to the Editor: Comments on papers published in JACMP or on any other matters of interest to clinical medical physics. These should not be more than 1250 (including the literature) and their publication is only based on the decision of the editor, who occasionally asks experts on the merit of the contents.
-Book Reviews: The editorial office solicits Book Reviews.
-Announcements of Forthcoming Meetings: The Editor may provide notice of forthcoming meetings, course offerings, and other events relevant to clinical medical physics.
-Parallel Opposed Editorial: We welcome topics relevant to clinical practice and medical physics profession. The contents can be controversial debate or opposed aspects of an issue. One author argues for the position and the other against. Each side of the debate contains an opening statement up to 800 words, followed by a rebuttal up to 500 words. Readers interested in participating in this series should contact the moderator with a proposed title and a short description of the topic