影响临时义齿增材制造精度的因素:系统综述。

Tingmin Zhang,Yuying Zheng,Guillermo Pradíes,Shizhu Bai
{"title":"影响临时义齿增材制造精度的因素:系统综述。","authors":"Tingmin Zhang,Yuying Zheng,Guillermo Pradíes,Shizhu Bai","doi":"10.1016/j.prosdent.2024.08.011","DOIUrl":null,"url":null,"abstract":"STATEMENT OF PROBLEM\r\nA systematic review of the effect of different factors on the accuracy of additively manufactured (AM) interim dental prostheses is lacking.\r\n\r\nPURPOSE\r\nThe purpose of this systematic review was to identify potential factors that may affect the accuracy of AM interim dental prostheses.\r\n\r\nMATERIAL AND METHODS\r\nThe review adhered to the guidelines outlined in the preferred reporting items for systematic reviews and meta-analyses (PRISMA) statement. The protocol was registered in the international prospective database of systematic reviews (PROSPERO) (CRD42024521564). The risk of bias in the included studies was assessed by using the Joanna Briggs Institute (JBI) checklist. Two reviewers performed an electronic search on the Web of Science, Scopus, PubMed, and Embase databases for articles published up to the end of 2023.\r\n\r\nRESULTS\r\nThe electronic search resulted in 406 studies. After removing duplicates, 205 studies remained. Thirty-one studies (30 in vitro and 1 in vivo) were included and categorized into 6 types: AM material (type and composition), prosthetic factor (tooth type, restoration size, finish line, abutment taper), AM system (technique and printer), AM parameters (layer thickness, printing orientation), postprocessing (rinsing, postpolymerization), and aging.\r\n\r\nCONCLUSIONS\r\nThe accuracy of AM interim dental prostheses is affected by factors that include the AM material, prosthetic factors, the AM system, the AM parameters, postprocessing, and aging.","PeriodicalId":501672,"journal":{"name":"The Journal of Prosthetic Dentistry","volume":"85 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Factors affecting accuracy in the additive manufacturing of interim dental prostheses: A systematic review.\",\"authors\":\"Tingmin Zhang,Yuying Zheng,Guillermo Pradíes,Shizhu Bai\",\"doi\":\"10.1016/j.prosdent.2024.08.011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"STATEMENT OF PROBLEM\\r\\nA systematic review of the effect of different factors on the accuracy of additively manufactured (AM) interim dental prostheses is lacking.\\r\\n\\r\\nPURPOSE\\r\\nThe purpose of this systematic review was to identify potential factors that may affect the accuracy of AM interim dental prostheses.\\r\\n\\r\\nMATERIAL AND METHODS\\r\\nThe review adhered to the guidelines outlined in the preferred reporting items for systematic reviews and meta-analyses (PRISMA) statement. The protocol was registered in the international prospective database of systematic reviews (PROSPERO) (CRD42024521564). The risk of bias in the included studies was assessed by using the Joanna Briggs Institute (JBI) checklist. Two reviewers performed an electronic search on the Web of Science, Scopus, PubMed, and Embase databases for articles published up to the end of 2023.\\r\\n\\r\\nRESULTS\\r\\nThe electronic search resulted in 406 studies. After removing duplicates, 205 studies remained. Thirty-one studies (30 in vitro and 1 in vivo) were included and categorized into 6 types: AM material (type and composition), prosthetic factor (tooth type, restoration size, finish line, abutment taper), AM system (technique and printer), AM parameters (layer thickness, printing orientation), postprocessing (rinsing, postpolymerization), and aging.\\r\\n\\r\\nCONCLUSIONS\\r\\nThe accuracy of AM interim dental prostheses is affected by factors that include the AM material, prosthetic factors, the AM system, the AM parameters, postprocessing, and aging.\",\"PeriodicalId\":501672,\"journal\":{\"name\":\"The Journal of Prosthetic Dentistry\",\"volume\":\"85 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of Prosthetic Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1016/j.prosdent.2024.08.011\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Prosthetic Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2024.08.011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本系统综述的目的是确定可能影响 AM 临时义齿准确性的潜在因素。该方案已在国际系统综述前瞻性数据库(PROSPERO)(CRD42024521564)中注册。采用乔安娜-布里格斯研究所(Joanna Briggs Institute,JBI)的检查表对纳入研究的偏倚风险进行评估。两名审稿人在 Web of Science、Scopus、PubMed 和 Embase 数据库中对截至 2023 年底发表的文章进行了电子检索。去除重复内容后,剩下 205 项研究。共纳入 31 项研究(30 项体外研究和 1 项体内研究),并将其分为 6 类:AM材料(类型和成分)、修复因素(牙齿类型、修复体大小、完成线、基台锥度)、AM系统(技术和打印机)、AM参数(层厚度、打印方向)、后处理(冲洗、后聚合)和老化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Factors affecting accuracy in the additive manufacturing of interim dental prostheses: A systematic review.
STATEMENT OF PROBLEM A systematic review of the effect of different factors on the accuracy of additively manufactured (AM) interim dental prostheses is lacking. PURPOSE The purpose of this systematic review was to identify potential factors that may affect the accuracy of AM interim dental prostheses. MATERIAL AND METHODS The review adhered to the guidelines outlined in the preferred reporting items for systematic reviews and meta-analyses (PRISMA) statement. The protocol was registered in the international prospective database of systematic reviews (PROSPERO) (CRD42024521564). The risk of bias in the included studies was assessed by using the Joanna Briggs Institute (JBI) checklist. Two reviewers performed an electronic search on the Web of Science, Scopus, PubMed, and Embase databases for articles published up to the end of 2023. RESULTS The electronic search resulted in 406 studies. After removing duplicates, 205 studies remained. Thirty-one studies (30 in vitro and 1 in vivo) were included and categorized into 6 types: AM material (type and composition), prosthetic factor (tooth type, restoration size, finish line, abutment taper), AM system (technique and printer), AM parameters (layer thickness, printing orientation), postprocessing (rinsing, postpolymerization), and aging. CONCLUSIONS The accuracy of AM interim dental prostheses is affected by factors that include the AM material, prosthetic factors, the AM system, the AM parameters, postprocessing, and aging.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信