Atiqah Mokhsin, Poonaresi Subramaniam, Sivasooriar Sivaneson, Nelson Nheu, Gobhy Ramaloo, Azana S. Hanifah, Sumitha B. Mahathevan, Mohanaraja Nadarajah, Gayathiri Sampasivam, Aletza Mohd Ismail, Thuhairah Abdul Rahman
{"title":"评估未离心血清和血浆分析物在采集后不同时间段的稳定性","authors":"Atiqah Mokhsin, Poonaresi Subramaniam, Sivasooriar Sivaneson, Nelson Nheu, Gobhy Ramaloo, Azana S. Hanifah, Sumitha B. Mahathevan, Mohanaraja Nadarajah, Gayathiri Sampasivam, Aletza Mohd Ismail, Thuhairah Abdul Rahman","doi":"10.1515/labmed-2024-0062","DOIUrl":null,"url":null,"abstract":"Objectives Our study aimed to assess the stability of 26 biochemistry analytes in serum or plasma samples separated from blood samples centrifuged at different time intervals after collection, simulating sample transport via despatch delivery systems. Methods Blood from forty-one volunteers were collected using five serum separator tubes (SST) and five fluoride oxalate tubes (FOT) for each volunteer following written informed consent. Each of the five tubes in both groups of SST and FOT was centrifuged at one of the time intervals: 0.5 h, 4 h, 8 h, 12 and 24 h after collection. These samples were left standing prior to centrifugation at room temperature. We calculated the percentage difference for each analyte between the 0.5 h and other time intervals to assess analyte stability. The percentage difference was compared to the desirable specification for bias and reference change value (RCV). Results Mean concentration of serum potassium showed a significant increase in the percentage RCV after 8 h, while CKMB showed an increase after 12 h of delayed centrifugation compared to the baseline (0.5 h). There were no significant percentage RCV for the other analytes at all timelines. Conclusions Serum potassium and CKMB were stable up to 8 and 12 h of delayed centrifugation respectively whilst all other analytes appear stable up to 24 h, suggesting that sample transport delay of up to 8 h, with the condition that room temperature is maintained, may not have a significant impact on accuracy of the biochemistry/immunochemistry test results.","PeriodicalId":55986,"journal":{"name":"Journal of Laboratory Medicine","volume":"5 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessing the stability of uncentrifuged serum and plasma analytes at various post-collection intervals\",\"authors\":\"Atiqah Mokhsin, Poonaresi Subramaniam, Sivasooriar Sivaneson, Nelson Nheu, Gobhy Ramaloo, Azana S. Hanifah, Sumitha B. Mahathevan, Mohanaraja Nadarajah, Gayathiri Sampasivam, Aletza Mohd Ismail, Thuhairah Abdul Rahman\",\"doi\":\"10.1515/labmed-2024-0062\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objectives Our study aimed to assess the stability of 26 biochemistry analytes in serum or plasma samples separated from blood samples centrifuged at different time intervals after collection, simulating sample transport via despatch delivery systems. Methods Blood from forty-one volunteers were collected using five serum separator tubes (SST) and five fluoride oxalate tubes (FOT) for each volunteer following written informed consent. Each of the five tubes in both groups of SST and FOT was centrifuged at one of the time intervals: 0.5 h, 4 h, 8 h, 12 and 24 h after collection. These samples were left standing prior to centrifugation at room temperature. We calculated the percentage difference for each analyte between the 0.5 h and other time intervals to assess analyte stability. The percentage difference was compared to the desirable specification for bias and reference change value (RCV). Results Mean concentration of serum potassium showed a significant increase in the percentage RCV after 8 h, while CKMB showed an increase after 12 h of delayed centrifugation compared to the baseline (0.5 h). There were no significant percentage RCV for the other analytes at all timelines. Conclusions Serum potassium and CKMB were stable up to 8 and 12 h of delayed centrifugation respectively whilst all other analytes appear stable up to 24 h, suggesting that sample transport delay of up to 8 h, with the condition that room temperature is maintained, may not have a significant impact on accuracy of the biochemistry/immunochemistry test results.\",\"PeriodicalId\":55986,\"journal\":{\"name\":\"Journal of Laboratory Medicine\",\"volume\":\"5 1\",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-08-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Laboratory Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/labmed-2024-0062\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Laboratory Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/labmed-2024-0062","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
Assessing the stability of uncentrifuged serum and plasma analytes at various post-collection intervals
Objectives Our study aimed to assess the stability of 26 biochemistry analytes in serum or plasma samples separated from blood samples centrifuged at different time intervals after collection, simulating sample transport via despatch delivery systems. Methods Blood from forty-one volunteers were collected using five serum separator tubes (SST) and five fluoride oxalate tubes (FOT) for each volunteer following written informed consent. Each of the five tubes in both groups of SST and FOT was centrifuged at one of the time intervals: 0.5 h, 4 h, 8 h, 12 and 24 h after collection. These samples were left standing prior to centrifugation at room temperature. We calculated the percentage difference for each analyte between the 0.5 h and other time intervals to assess analyte stability. The percentage difference was compared to the desirable specification for bias and reference change value (RCV). Results Mean concentration of serum potassium showed a significant increase in the percentage RCV after 8 h, while CKMB showed an increase after 12 h of delayed centrifugation compared to the baseline (0.5 h). There were no significant percentage RCV for the other analytes at all timelines. Conclusions Serum potassium and CKMB were stable up to 8 and 12 h of delayed centrifugation respectively whilst all other analytes appear stable up to 24 h, suggesting that sample transport delay of up to 8 h, with the condition that room temperature is maintained, may not have a significant impact on accuracy of the biochemistry/immunochemistry test results.
期刊介绍:
The Journal of Laboratory Medicine (JLM) is a bi-monthly published journal that reports on the latest developments in laboratory medicine. Particular focus is placed on the diagnostic aspects of the clinical laboratory, although technical, regulatory, and educational topics are equally covered. The Journal specializes in the publication of high-standard, competent and timely review articles on clinical, methodological and pathogenic aspects of modern laboratory diagnostics. These reviews are critically reviewed by expert reviewers and JLM’s Associate Editors who are specialists in the various subdisciplines of laboratory medicine. In addition, JLM publishes original research articles, case reports, point/counterpoint articles and letters to the editor, all of which are peer reviewed by at least two experts in the field.