M. Bakhshipour, F. Namdari, B. Rezaeealam, M. Sedaghat
{"title":"基于小波变换的电力变压器无设置差动保护","authors":"M. Bakhshipour, F. Namdari, B. Rezaeealam, M. Sedaghat","doi":"10.1007/s40998-024-00752-8","DOIUrl":null,"url":null,"abstract":"<p>This paper presents a novel algorithm for power transformer differential protection based on wavelet transform (WT) and introduces new indices to distinguish internal faults from normal operating conditions and the occurrence of the inrush current. The proposed setting-less algorithm has no limits on the structure, dimension, capacity, and core type of the transformer. For this purpose, six indices based on fault detection functions extracted from WT transform are presented. Then, weighting factors for the indices by using the least squares method are calculated. In order to validate the proposed method, the approach has been evaluated on four transformers with 2 kVA, 10 kVA, 400 kVA, and 125 MVA. The success rate of fault detection in 10 kVA, and 125 MVA transformers was 100% and in 2 kVA and 400 kVA transformers was 93.33% and 94.44%, respectively. Also, the proposed algorithm has a remarkable capability in fast fault detection to protect the power transformer.</p>","PeriodicalId":49064,"journal":{"name":"Iranian Journal of Science and Technology-Transactions of Electrical Engineering","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Setting-Less Differential Protection of Power Transformers Based on Wavelet Transform\",\"authors\":\"M. Bakhshipour, F. Namdari, B. Rezaeealam, M. Sedaghat\",\"doi\":\"10.1007/s40998-024-00752-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>This paper presents a novel algorithm for power transformer differential protection based on wavelet transform (WT) and introduces new indices to distinguish internal faults from normal operating conditions and the occurrence of the inrush current. The proposed setting-less algorithm has no limits on the structure, dimension, capacity, and core type of the transformer. For this purpose, six indices based on fault detection functions extracted from WT transform are presented. Then, weighting factors for the indices by using the least squares method are calculated. In order to validate the proposed method, the approach has been evaluated on four transformers with 2 kVA, 10 kVA, 400 kVA, and 125 MVA. The success rate of fault detection in 10 kVA, and 125 MVA transformers was 100% and in 2 kVA and 400 kVA transformers was 93.33% and 94.44%, respectively. Also, the proposed algorithm has a remarkable capability in fast fault detection to protect the power transformer.</p>\",\"PeriodicalId\":49064,\"journal\":{\"name\":\"Iranian Journal of Science and Technology-Transactions of Electrical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian Journal of Science and Technology-Transactions of Electrical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s40998-024-00752-8\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Science and Technology-Transactions of Electrical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s40998-024-00752-8","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Setting-Less Differential Protection of Power Transformers Based on Wavelet Transform
This paper presents a novel algorithm for power transformer differential protection based on wavelet transform (WT) and introduces new indices to distinguish internal faults from normal operating conditions and the occurrence of the inrush current. The proposed setting-less algorithm has no limits on the structure, dimension, capacity, and core type of the transformer. For this purpose, six indices based on fault detection functions extracted from WT transform are presented. Then, weighting factors for the indices by using the least squares method are calculated. In order to validate the proposed method, the approach has been evaluated on four transformers with 2 kVA, 10 kVA, 400 kVA, and 125 MVA. The success rate of fault detection in 10 kVA, and 125 MVA transformers was 100% and in 2 kVA and 400 kVA transformers was 93.33% and 94.44%, respectively. Also, the proposed algorithm has a remarkable capability in fast fault detection to protect the power transformer.
期刊介绍:
Transactions of Electrical Engineering is to foster the growth of scientific research in all branches of electrical engineering and its related grounds and to provide a medium by means of which the fruits of these researches may be brought to the attentionof the world’s scientific communities.
The journal has the focus on the frontier topics in the theoretical, mathematical, numerical, experimental and scientific developments in electrical engineering as well
as applications of established techniques to new domains in various electical engineering disciplines such as:
Bio electric, Bio mechanics, Bio instrument, Microwaves, Wave Propagation, Communication Theory, Channel Estimation, radar & sonar system, Signal Processing, image processing, Artificial Neural Networks, Data Mining and Machine Learning, Fuzzy Logic and Systems, Fuzzy Control, Optimal & Robust ControlNavigation & Estimation Theory, Power Electronics & Drives, Power Generation & Management The editors will welcome papers from all professors and researchers from universities, research centers,
organizations, companies and industries from all over the world in the hope that this will advance the scientific standards of the journal and provide a channel of communication between Iranian Scholars and their colleague in other parts of the world.