使用 3D 扫描仪测量泡沫密度

IF 3.2 4区 工程技术 Q2 CHEMISTRY, APPLIED
Fabrizio Errichiello, Daniele Amato, Mario Penati, Ernesto Di Maio
{"title":"使用 3D 扫描仪测量泡沫密度","authors":"Fabrizio Errichiello, Daniele Amato, Mario Penati, Ernesto Di Maio","doi":"10.1177/0021955x241281880","DOIUrl":null,"url":null,"abstract":"In this work, we used a 3D scanner for the volume measurement of foamed samples, a long-standing problem in the density evaluation of foams. The 3D scanning density measurement method can be selected as an alternative to or in combination with well-established, classical methods that involve the use of instruments like a caliper, a pycnometer, or other devices based on displacement or flotation principles. In particular, the classical methods show some limitations when the foamed sample geometry is irregular, when the polymer is highly hygroscopic, and when it has open porosities. We have tested numerous foamed samples of different sizes, shapes, densities, materials, and morphologies. We utilized different 3D scanner configurations for their volume measurement and compared the results with geometrical and displacement methods, when possible. Results showed that the proposed method is highly accurate, reproducible, and simple, although some specific precautions should be put in place to avoid misinterpretation by the shape-reconstructing software.","PeriodicalId":15236,"journal":{"name":"Journal of Cellular Plastics","volume":"1 1","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Foam density measurement using a 3D scanner\",\"authors\":\"Fabrizio Errichiello, Daniele Amato, Mario Penati, Ernesto Di Maio\",\"doi\":\"10.1177/0021955x241281880\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, we used a 3D scanner for the volume measurement of foamed samples, a long-standing problem in the density evaluation of foams. The 3D scanning density measurement method can be selected as an alternative to or in combination with well-established, classical methods that involve the use of instruments like a caliper, a pycnometer, or other devices based on displacement or flotation principles. In particular, the classical methods show some limitations when the foamed sample geometry is irregular, when the polymer is highly hygroscopic, and when it has open porosities. We have tested numerous foamed samples of different sizes, shapes, densities, materials, and morphologies. We utilized different 3D scanner configurations for their volume measurement and compared the results with geometrical and displacement methods, when possible. Results showed that the proposed method is highly accurate, reproducible, and simple, although some specific precautions should be put in place to avoid misinterpretation by the shape-reconstructing software.\",\"PeriodicalId\":15236,\"journal\":{\"name\":\"Journal of Cellular Plastics\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cellular Plastics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/0021955x241281880\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cellular Plastics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/0021955x241281880","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, APPLIED","Score":null,"Total":0}
引用次数: 0

摘要

在这项工作中,我们使用三维扫描仪测量发泡样品的体积,这是泡沫密度评估中一个长期存在的问题。三维扫描密度测量方法可以替代或结合使用卡尺、比重计等仪器或其他基于位移或浮选原理的设备的成熟经典方法。特别是当发泡样品的几何形状不规则、聚合物吸湿性强以及具有开放孔隙时,传统方法就会显示出一定的局限性。我们测试了大量不同尺寸、形状、密度、材料和形态的发泡样品。我们利用不同的三维扫描仪配置进行体积测量,并尽可能将结果与几何和位移方法进行比较。结果表明,所建议的方法准确度高、可重复性好且操作简单,但应采取一些特定的预防措施,以避免形状重构软件产生误解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Foam density measurement using a 3D scanner
In this work, we used a 3D scanner for the volume measurement of foamed samples, a long-standing problem in the density evaluation of foams. The 3D scanning density measurement method can be selected as an alternative to or in combination with well-established, classical methods that involve the use of instruments like a caliper, a pycnometer, or other devices based on displacement or flotation principles. In particular, the classical methods show some limitations when the foamed sample geometry is irregular, when the polymer is highly hygroscopic, and when it has open porosities. We have tested numerous foamed samples of different sizes, shapes, densities, materials, and morphologies. We utilized different 3D scanner configurations for their volume measurement and compared the results with geometrical and displacement methods, when possible. Results showed that the proposed method is highly accurate, reproducible, and simple, although some specific precautions should be put in place to avoid misinterpretation by the shape-reconstructing software.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Cellular Plastics
Journal of Cellular Plastics 工程技术-高分子科学
CiteScore
5.00
自引率
16.00%
发文量
19
审稿时长
3 months
期刊介绍: The Journal of Cellular Plastics is a fully peer reviewed international journal that publishes original research and review articles covering the latest advances in foamed plastics technology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信