基于流体动力门控的分子通信发射机的实验特性分析

Eren Akyol, Ahmet Baha Ozturk, Iman Mokari Bolhassan, Murat Kuscu
{"title":"基于流体动力门控的分子通信发射机的实验特性分析","authors":"Eren Akyol, Ahmet Baha Ozturk, Iman Mokari Bolhassan, Murat Kuscu","doi":"arxiv-2408.09835","DOIUrl":null,"url":null,"abstract":"Molecular communication (MC) is a bio-inspired method of transmitting\ninformation using biochemical signals, promising for novel medical,\nagricultural, and environmental applications at the intersection of bio-,\nnano-, and communication technologies. Developing reliable MC systems for\nhigh-rate information transfer remains challenging due to the complex and\ndynamic nature of application environments and the physical and resource\nlimitations of micro/nanoscale transmitters and receivers. Microfluidics can\nhelp overcome many such practical challenges by enabling testbeds that can\nreplicate the application media with precise control over flow conditions.\nHowever, existing microfluidic MC testbeds face significant limitations in\nchemical signal generation with programmable signal waveforms, e.g., in terms\nof pulse width. To tackle this, we previously proposed a practical microfluidic\nMC transmitter architecture based on the hydrodynamic gating technique, a\nprevalent chemical waveform generation method. This paper reports the\nexperimental validation and characterization of this method, examining its\nprecision in terms of spatiotemporal control on the generated molecular\nconcentration pulses. We detail the fabrication of the transmitter, its working\nmechanism and discuss its potential limitations based on empirical data. We\nshow that the microfluidic transmitter is capable of providing precise,\nprogrammable, and reproducible molecular concentration pulses, which would\nfacilitate the experimental research in MC.","PeriodicalId":501168,"journal":{"name":"arXiv - CS - Emerging Technologies","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental Characterization of Hydrodynamic Gating-Based Molecular Communication Transmitter\",\"authors\":\"Eren Akyol, Ahmet Baha Ozturk, Iman Mokari Bolhassan, Murat Kuscu\",\"doi\":\"arxiv-2408.09835\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Molecular communication (MC) is a bio-inspired method of transmitting\\ninformation using biochemical signals, promising for novel medical,\\nagricultural, and environmental applications at the intersection of bio-,\\nnano-, and communication technologies. Developing reliable MC systems for\\nhigh-rate information transfer remains challenging due to the complex and\\ndynamic nature of application environments and the physical and resource\\nlimitations of micro/nanoscale transmitters and receivers. Microfluidics can\\nhelp overcome many such practical challenges by enabling testbeds that can\\nreplicate the application media with precise control over flow conditions.\\nHowever, existing microfluidic MC testbeds face significant limitations in\\nchemical signal generation with programmable signal waveforms, e.g., in terms\\nof pulse width. To tackle this, we previously proposed a practical microfluidic\\nMC transmitter architecture based on the hydrodynamic gating technique, a\\nprevalent chemical waveform generation method. This paper reports the\\nexperimental validation and characterization of this method, examining its\\nprecision in terms of spatiotemporal control on the generated molecular\\nconcentration pulses. We detail the fabrication of the transmitter, its working\\nmechanism and discuss its potential limitations based on empirical data. We\\nshow that the microfluidic transmitter is capable of providing precise,\\nprogrammable, and reproducible molecular concentration pulses, which would\\nfacilitate the experimental research in MC.\",\"PeriodicalId\":501168,\"journal\":{\"name\":\"arXiv - CS - Emerging Technologies\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"arXiv - CS - Emerging Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/arxiv-2408.09835\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - CS - Emerging Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2408.09835","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

分子通信(MC)是一种利用生化信号传输信息的生物启发方法,有望在生物、纳米和通信技术的交叉领域实现新型医疗、农业和环境应用。由于应用环境的复杂性和动态性,以及微/纳米级发射器和接收器的物理和资源限制,开发可靠的 MC 系统以实现高速信息传输仍具有挑战性。然而,现有的微流体 MC 试验台在可编程信号波形(如脉冲宽度)的化学信号生成方面面临很大限制。为了解决这个问题,我们之前提出了一种基于流体动力门控技术的实用微流控发射器架构,这是一种有效的化学波形生成方法。本文报告了这一方法的实验验证和特征描述,从生成分子浓度脉冲的时空控制方面考察了这一方法的精确性。我们详细介绍了发射器的制造、工作机制,并根据经验数据讨论了其潜在的局限性。结果表明,微流控发射器能够提供精确、可编程、可重现的分子浓度脉冲,这将有助于 MC 的实验研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental Characterization of Hydrodynamic Gating-Based Molecular Communication Transmitter
Molecular communication (MC) is a bio-inspired method of transmitting information using biochemical signals, promising for novel medical, agricultural, and environmental applications at the intersection of bio-, nano-, and communication technologies. Developing reliable MC systems for high-rate information transfer remains challenging due to the complex and dynamic nature of application environments and the physical and resource limitations of micro/nanoscale transmitters and receivers. Microfluidics can help overcome many such practical challenges by enabling testbeds that can replicate the application media with precise control over flow conditions. However, existing microfluidic MC testbeds face significant limitations in chemical signal generation with programmable signal waveforms, e.g., in terms of pulse width. To tackle this, we previously proposed a practical microfluidic MC transmitter architecture based on the hydrodynamic gating technique, a prevalent chemical waveform generation method. This paper reports the experimental validation and characterization of this method, examining its precision in terms of spatiotemporal control on the generated molecular concentration pulses. We detail the fabrication of the transmitter, its working mechanism and discuss its potential limitations based on empirical data. We show that the microfluidic transmitter is capable of providing precise, programmable, and reproducible molecular concentration pulses, which would facilitate the experimental research in MC.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信