利用新型磁性纳米复合材料的三维打印技术制造双平行腔电磁微泵

IF 1.9 4区 工程技术 Q2 Engineering
Mohammad Tahmasebipour, Shadi Ebrahimi, Mohammad Dehghan, Fatemeh Anousheh
{"title":"利用新型磁性纳米复合材料的三维打印技术制造双平行腔电磁微泵","authors":"Mohammad Tahmasebipour, Shadi Ebrahimi, Mohammad Dehghan, Fatemeh Anousheh","doi":"10.1007/s12541-024-01109-1","DOIUrl":null,"url":null,"abstract":"<p>Micropumps have found wide applications in biomedicine, micro-electro-mechanical systems, and microfluidic systems. This study presents a novel nozzle/diffuser micropump with two parallel chambers fabricated using the stereolithography (SLA) 3D printing method from FLGPCL04-Fe<sub>3</sub>O<sub>4</sub> magnetic nanocomposite. The proposed valveless micropump is an attractive alternative for drug delivery applications due to its effective controllability, cost-effectiveness, and mass production capability. The dual chamber structure is able to overcome the disadvantages of the single chamber micropumps like providing higher flow rates. In this micropump, a maximum membrane displacement of 65 μm has been achieved using 5 wt% magnetic nanoparticles concentration for a 30-turn microcoil and applied current of 1000 mA. The fluid flow was evaluated through the membrane displacement using numerical simulations in COMSOL Multiphysics 5. Based on the experimental results, a maximum flow rate of 82 nL/s has been achieved under dual-chamber loading while loading one of the chambers leading to a maximum flow rate of 62.5 nL/s.</p>","PeriodicalId":14359,"journal":{"name":"International Journal of Precision Engineering and Manufacturing","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Dual-Parallel Chamber Electromagnetic Micropump Fabricated Using 3D Printing Method from a Novel Magnetic Nanocomposite Material\",\"authors\":\"Mohammad Tahmasebipour, Shadi Ebrahimi, Mohammad Dehghan, Fatemeh Anousheh\",\"doi\":\"10.1007/s12541-024-01109-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Micropumps have found wide applications in biomedicine, micro-electro-mechanical systems, and microfluidic systems. This study presents a novel nozzle/diffuser micropump with two parallel chambers fabricated using the stereolithography (SLA) 3D printing method from FLGPCL04-Fe<sub>3</sub>O<sub>4</sub> magnetic nanocomposite. The proposed valveless micropump is an attractive alternative for drug delivery applications due to its effective controllability, cost-effectiveness, and mass production capability. The dual chamber structure is able to overcome the disadvantages of the single chamber micropumps like providing higher flow rates. In this micropump, a maximum membrane displacement of 65 μm has been achieved using 5 wt% magnetic nanoparticles concentration for a 30-turn microcoil and applied current of 1000 mA. The fluid flow was evaluated through the membrane displacement using numerical simulations in COMSOL Multiphysics 5. Based on the experimental results, a maximum flow rate of 82 nL/s has been achieved under dual-chamber loading while loading one of the chambers leading to a maximum flow rate of 62.5 nL/s.</p>\",\"PeriodicalId\":14359,\"journal\":{\"name\":\"International Journal of Precision Engineering and Manufacturing\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Precision Engineering and Manufacturing\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s12541-024-01109-1\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Precision Engineering and Manufacturing","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s12541-024-01109-1","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

微泵在生物医学、微机电系统和微流控系统中有着广泛的应用。本研究利用 FLGPCL04-Fe3O4 磁性纳米复合材料,采用立体光刻(SLA)三维打印方法,制作了一种带有两个平行腔的新型喷嘴/扩散器微泵。所提出的无阀微泵具有有效的可控性、成本效益和批量生产能力,是药物输送应用的一种极具吸引力的替代方案。双腔结构能够克服单腔微泵的缺点,如提供更高的流速。在这种微泵中,使用浓度为 5 wt% 的磁性纳米粒子,30 圈微线圈和 1000 mA 的外加电流,实现了 65 μm 的最大膜位移。使用 COMSOL Multiphysics 5 进行数值模拟,评估了膜位移时的流体流动情况。根据实验结果,在双室加载情况下,最大流速为 82 nL/s,而加载其中一个室时,最大流速为 62.5 nL/s。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

A Dual-Parallel Chamber Electromagnetic Micropump Fabricated Using 3D Printing Method from a Novel Magnetic Nanocomposite Material

A Dual-Parallel Chamber Electromagnetic Micropump Fabricated Using 3D Printing Method from a Novel Magnetic Nanocomposite Material

Micropumps have found wide applications in biomedicine, micro-electro-mechanical systems, and microfluidic systems. This study presents a novel nozzle/diffuser micropump with two parallel chambers fabricated using the stereolithography (SLA) 3D printing method from FLGPCL04-Fe3O4 magnetic nanocomposite. The proposed valveless micropump is an attractive alternative for drug delivery applications due to its effective controllability, cost-effectiveness, and mass production capability. The dual chamber structure is able to overcome the disadvantages of the single chamber micropumps like providing higher flow rates. In this micropump, a maximum membrane displacement of 65 μm has been achieved using 5 wt% magnetic nanoparticles concentration for a 30-turn microcoil and applied current of 1000 mA. The fluid flow was evaluated through the membrane displacement using numerical simulations in COMSOL Multiphysics 5. Based on the experimental results, a maximum flow rate of 82 nL/s has been achieved under dual-chamber loading while loading one of the chambers leading to a maximum flow rate of 62.5 nL/s.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
10.50%
发文量
115
审稿时长
3-6 weeks
期刊介绍: The International Journal of Precision Engineering and Manufacturing accepts original contributions on all aspects of precision engineering and manufacturing. The journal specific focus areas include, but are not limited to: - Precision Machining Processes - Manufacturing Systems - Robotics and Automation - Machine Tools - Design and Materials - Biomechanical Engineering - Nano/Micro Technology - Rapid Prototyping and Manufacturing - Measurements and Control Surveys and reviews will also be planned in consultation with the Editorial Board.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信