儿科患者喉罩与喉管试验(LaMaTuPe):单盲、开放标签、随机对照试验。

IF 3.1 4区 医学 Q1 EMERGENCY MEDICINE
Stephan Katzenschlager,Stefan Mohr,Nikolai Kaltschmidt,Franziska Peterstorfer,Frank Weilbacher,Patrick Günther,Markus Ries,Markus A Weigand,Erik Popp
{"title":"儿科患者喉罩与喉管试验(LaMaTuPe):单盲、开放标签、随机对照试验。","authors":"Stephan Katzenschlager,Stefan Mohr,Nikolai Kaltschmidt,Franziska Peterstorfer,Frank Weilbacher,Patrick Günther,Markus Ries,Markus A Weigand,Erik Popp","doi":"10.1097/mej.0000000000001178","DOIUrl":null,"url":null,"abstract":"BACKGROUND\r\nIn hypoxemic children with difficult airway, or for minor elective procedures, the use of a supraglottic airway device may be preferred to endotracheal intubation, whether with a laryngeal mask or laryngeal tube. Second-generation laryngeal masks may offer a better safety profile. Whether they should be preferred to laryngeal tubes is unknown. This study aimed to compare the efficacy and safety of second-generation laryngeal masks and laryngeal tubes in children.\r\n\r\nMETHODS\r\nThis randomised-controlled trial was conducted in a single university hospital in children <18 years undergoing elective anaesthesia in urology, minor paediatric surgery and gynaecology. Patients were 1 : 1 randomised to the laryngeal mask or laryngeal tube group. Children were allocated a second-generation laryngeal tube or a second-generation laryngeal mask as the primary airway device. The primary endpoint was insertion time. Secondary endpoints included first-attempt success, overall success and complications, which included hypoxia (SpO2 < 90%), laryngospasm, bronchospasm, aspiration and bleeding.\r\n\r\nRESULTS\r\nIn total, 135 patients were randomised, with 61 allocated to the laryngeal tube and 74 to the laryngeal mask group, with a median age of 5.4 and 4.9 years, respectively. Median insertion time was significantly longer in the laryngeal tube group (37 vs. 31 s; difference of medians: 6.0 s; 95% confidence interval: 0.0-13.0). The laryngeal tube had a significantly lower first-attempt (41.0%) and overall success rate (45.9%) than the laryngeal mask (90.5% and 97.3%, respectively). Those allocated to the laryngeal tube group had a higher ratio of complications (27.8%) compared to the laryngeal mask group (2.7%).\r\n\r\nCONCLUSION\r\nThis randomised-controlled trial reported that in children undergoing elective anaesthesia, the use of a laryngeal tube was associated with a longer insertion time.","PeriodicalId":11893,"journal":{"name":"European Journal of Emergency Medicine","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Laryngeal mask vs. laryngeal tube trial in paediatric patients (LaMaTuPe): a single-blinded, open-label, randomised-controlled trial.\",\"authors\":\"Stephan Katzenschlager,Stefan Mohr,Nikolai Kaltschmidt,Franziska Peterstorfer,Frank Weilbacher,Patrick Günther,Markus Ries,Markus A Weigand,Erik Popp\",\"doi\":\"10.1097/mej.0000000000001178\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BACKGROUND\\r\\nIn hypoxemic children with difficult airway, or for minor elective procedures, the use of a supraglottic airway device may be preferred to endotracheal intubation, whether with a laryngeal mask or laryngeal tube. Second-generation laryngeal masks may offer a better safety profile. Whether they should be preferred to laryngeal tubes is unknown. This study aimed to compare the efficacy and safety of second-generation laryngeal masks and laryngeal tubes in children.\\r\\n\\r\\nMETHODS\\r\\nThis randomised-controlled trial was conducted in a single university hospital in children <18 years undergoing elective anaesthesia in urology, minor paediatric surgery and gynaecology. Patients were 1 : 1 randomised to the laryngeal mask or laryngeal tube group. Children were allocated a second-generation laryngeal tube or a second-generation laryngeal mask as the primary airway device. The primary endpoint was insertion time. Secondary endpoints included first-attempt success, overall success and complications, which included hypoxia (SpO2 < 90%), laryngospasm, bronchospasm, aspiration and bleeding.\\r\\n\\r\\nRESULTS\\r\\nIn total, 135 patients were randomised, with 61 allocated to the laryngeal tube and 74 to the laryngeal mask group, with a median age of 5.4 and 4.9 years, respectively. Median insertion time was significantly longer in the laryngeal tube group (37 vs. 31 s; difference of medians: 6.0 s; 95% confidence interval: 0.0-13.0). The laryngeal tube had a significantly lower first-attempt (41.0%) and overall success rate (45.9%) than the laryngeal mask (90.5% and 97.3%, respectively). Those allocated to the laryngeal tube group had a higher ratio of complications (27.8%) compared to the laryngeal mask group (2.7%).\\r\\n\\r\\nCONCLUSION\\r\\nThis randomised-controlled trial reported that in children undergoing elective anaesthesia, the use of a laryngeal tube was associated with a longer insertion time.\",\"PeriodicalId\":11893,\"journal\":{\"name\":\"European Journal of Emergency Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Emergency Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/mej.0000000000001178\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"EMERGENCY MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Emergency Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/mej.0000000000001178","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景在低氧血症儿童气道困难或进行小型择期手术时,使用声门上气道装置可能优于气管插管,无论是使用喉罩还是喉管。第二代喉罩可能具有更好的安全性。至于喉罩是否优于喉管还不得而知。这项研究旨在比较第二代喉罩和喉管在儿童中的有效性和安全性。方法这项随机对照试验在一家大学医院进行,对象是接受泌尿科、儿科小手术和妇科择期麻醉的 18 岁以下儿童。患者以 1 :1 的比例随机分配到喉罩组或喉管组。患儿被分配使用第二代喉管或第二代喉罩作为主要气道装置。主要终点是插入时间。次要终点包括首次尝试成功率、总体成功率和并发症,其中并发症包括缺氧(SpO2 < 90%)、喉痉挛、支气管痉挛、吸入和出血。结果共有 135 名患者接受了随机治疗,其中 61 人被分配到喉管组,74 人被分配到喉罩组,中位年龄分别为 5.4 岁和 4.9 岁。喉管组的中位插入时间明显更长(37 秒对 31 秒;中位数差异:6.0 秒;95% 置信区间:0.0-13.0)。喉管首次尝试成功率(41.0%)和总体成功率(45.9%)明显低于喉罩(分别为 90.5% 和 97.3%)。与喉罩组相比,喉管组的并发症发生率(27.8%)更高(2.7%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Laryngeal mask vs. laryngeal tube trial in paediatric patients (LaMaTuPe): a single-blinded, open-label, randomised-controlled trial.
BACKGROUND In hypoxemic children with difficult airway, or for minor elective procedures, the use of a supraglottic airway device may be preferred to endotracheal intubation, whether with a laryngeal mask or laryngeal tube. Second-generation laryngeal masks may offer a better safety profile. Whether they should be preferred to laryngeal tubes is unknown. This study aimed to compare the efficacy and safety of second-generation laryngeal masks and laryngeal tubes in children. METHODS This randomised-controlled trial was conducted in a single university hospital in children <18 years undergoing elective anaesthesia in urology, minor paediatric surgery and gynaecology. Patients were 1 : 1 randomised to the laryngeal mask or laryngeal tube group. Children were allocated a second-generation laryngeal tube or a second-generation laryngeal mask as the primary airway device. The primary endpoint was insertion time. Secondary endpoints included first-attempt success, overall success and complications, which included hypoxia (SpO2 < 90%), laryngospasm, bronchospasm, aspiration and bleeding. RESULTS In total, 135 patients were randomised, with 61 allocated to the laryngeal tube and 74 to the laryngeal mask group, with a median age of 5.4 and 4.9 years, respectively. Median insertion time was significantly longer in the laryngeal tube group (37 vs. 31 s; difference of medians: 6.0 s; 95% confidence interval: 0.0-13.0). The laryngeal tube had a significantly lower first-attempt (41.0%) and overall success rate (45.9%) than the laryngeal mask (90.5% and 97.3%, respectively). Those allocated to the laryngeal tube group had a higher ratio of complications (27.8%) compared to the laryngeal mask group (2.7%). CONCLUSION This randomised-controlled trial reported that in children undergoing elective anaesthesia, the use of a laryngeal tube was associated with a longer insertion time.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.60
自引率
27.30%
发文量
180
审稿时长
6-12 weeks
期刊介绍: The European Journal of Emergency Medicine is the official journal of the European Society for Emergency Medicine. It is devoted to serving the European emergency medicine community and to promoting European standards of training, diagnosis and care in this rapidly growing field. Published bimonthly, the Journal offers original papers on all aspects of acute injury and sudden illness, including: emergency medicine, anaesthesiology, cardiology, disaster medicine, intensive care, internal medicine, orthopaedics, paediatrics, toxicology and trauma care. It addresses issues on the organization of emergency services in hospitals and in the community and examines postgraduate training from European and global perspectives. The Journal also publishes papers focusing on the different models of emergency healthcare delivery in Europe and beyond. With a multidisciplinary approach, the European Journal of Emergency Medicine publishes scientific research, topical reviews, news of meetings and events of interest to the emergency medicine community. Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool. ​
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信