基于电场效应的新型油纸水分平衡曲线

IF 3.8 2区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC
Hao Luo;Li Cheng;Zhiling Chen;Wangjun Deng;Xuetong Zhao;Lijun Yang;Ruijin Liao
{"title":"基于电场效应的新型油纸水分平衡曲线","authors":"Hao Luo;Li Cheng;Zhiling Chen;Wangjun Deng;Xuetong Zhao;Lijun Yang;Ruijin Liao","doi":"10.1109/TPWRD.2024.3459047","DOIUrl":null,"url":null,"abstract":"Moisture equilibrium curve of oil paper (MEC-OP) is an important and commonly used foundational curve in transformer design and condition assessment. For AC transformers, the MEC-OP is weakly affected by the electric field, so only considering the temperature. However, for the converter transformer, the DC electric field present inside has not yet been considered. Therefore, Based on a new method of moisture distribution measurement by terahertz spectroscopy, a novel curve of MEC-OP considering the effect of DC electric field is obtained. The results show that the moisture in oil and paper increases as the field strength grows, the reason leading to the rise of moisture may be the effect of electric field force and dielectrophoretic force, while molecular simulation calculation is employed to support in explaining the experimental phenomena. Then, the coefficient of the field strength affecting the moisture content is introduced to correct the MEC-OP, and the moisture of cardboard calculated at 25 kV/mm under 40 °C, 60 °C, and 80 °C increases by 15.65%, 19.68%, and 32.92%, respectively. This research fills a gap in the effect of DC electric field on the MEC-OP under the converter transformer and provides support for the accurate calculation of the moisture in insulating paper.","PeriodicalId":13498,"journal":{"name":"IEEE Transactions on Power Delivery","volume":"39 6","pages":"3268-3278"},"PeriodicalIF":3.8000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Novel Curve of Moisture Equilibrium of Oil Paper Based on the Effect of Electric Field\",\"authors\":\"Hao Luo;Li Cheng;Zhiling Chen;Wangjun Deng;Xuetong Zhao;Lijun Yang;Ruijin Liao\",\"doi\":\"10.1109/TPWRD.2024.3459047\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Moisture equilibrium curve of oil paper (MEC-OP) is an important and commonly used foundational curve in transformer design and condition assessment. For AC transformers, the MEC-OP is weakly affected by the electric field, so only considering the temperature. However, for the converter transformer, the DC electric field present inside has not yet been considered. Therefore, Based on a new method of moisture distribution measurement by terahertz spectroscopy, a novel curve of MEC-OP considering the effect of DC electric field is obtained. The results show that the moisture in oil and paper increases as the field strength grows, the reason leading to the rise of moisture may be the effect of electric field force and dielectrophoretic force, while molecular simulation calculation is employed to support in explaining the experimental phenomena. Then, the coefficient of the field strength affecting the moisture content is introduced to correct the MEC-OP, and the moisture of cardboard calculated at 25 kV/mm under 40 °C, 60 °C, and 80 °C increases by 15.65%, 19.68%, and 32.92%, respectively. This research fills a gap in the effect of DC electric field on the MEC-OP under the converter transformer and provides support for the accurate calculation of the moisture in insulating paper.\",\"PeriodicalId\":13498,\"journal\":{\"name\":\"IEEE Transactions on Power Delivery\",\"volume\":\"39 6\",\"pages\":\"3268-3278\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Power Delivery\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10679091/\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Power Delivery","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10679091/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

油纸水分平衡曲线(MEC-OP)是变压器设计和状态评估中常用的重要基础曲线。对于交流变压器,MEC-OP 受电场影响较弱,因此只考虑温度。然而,对于换流变压器,尚未考虑其内部存在的直流电场。因此,基于太赫兹光谱湿度分布测量的新方法,得到了考虑直流电场影响的 MEC-OP 新曲线。结果表明,油和纸张中的水分会随着电场强度的增加而增加,导致水分增加的原因可能是电场力和介电泳力的作用,同时采用分子模拟计算来辅助解释实验现象。然后,引入影响水分含量的场强系数来修正 MEC-OP,结果表明在 25 kV/mm 条件下,在 40 ℃、60 ℃ 和 80 ℃ 下计算得到的纸板水分分别增加了 15.65%、19.68% 和 32.92%。这项研究填补了直流电场对换流变压器下 MEC-OP 影响的空白,为准确计算绝缘纸中的水分提供了支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Novel Curve of Moisture Equilibrium of Oil Paper Based on the Effect of Electric Field
Moisture equilibrium curve of oil paper (MEC-OP) is an important and commonly used foundational curve in transformer design and condition assessment. For AC transformers, the MEC-OP is weakly affected by the electric field, so only considering the temperature. However, for the converter transformer, the DC electric field present inside has not yet been considered. Therefore, Based on a new method of moisture distribution measurement by terahertz spectroscopy, a novel curve of MEC-OP considering the effect of DC electric field is obtained. The results show that the moisture in oil and paper increases as the field strength grows, the reason leading to the rise of moisture may be the effect of electric field force and dielectrophoretic force, while molecular simulation calculation is employed to support in explaining the experimental phenomena. Then, the coefficient of the field strength affecting the moisture content is introduced to correct the MEC-OP, and the moisture of cardboard calculated at 25 kV/mm under 40 °C, 60 °C, and 80 °C increases by 15.65%, 19.68%, and 32.92%, respectively. This research fills a gap in the effect of DC electric field on the MEC-OP under the converter transformer and provides support for the accurate calculation of the moisture in insulating paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Transactions on Power Delivery
IEEE Transactions on Power Delivery 工程技术-工程:电子与电气
CiteScore
9.00
自引率
13.60%
发文量
513
审稿时长
6 months
期刊介绍: The scope of the Society embraces planning, research, development, design, application, construction, installation and operation of apparatus, equipment, structures, materials and systems for the safe, reliable and economic generation, transmission, distribution, conversion, measurement and control of electric energy. It includes the developing of engineering standards, the providing of information and instruction to the public and to legislators, as well as technical scientific, literary, educational and other activities that contribute to the electric power discipline or utilize the techniques or products within this discipline.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信