Joseph D. Bozzay MD , Peter J. Kneuertz MD , David S. Xu MD , Timur P. Sarac MD , John Bozinovski MD , Kristine C. Orion MD
{"title":"用阔筋膜包裹的侧主动脉移植物分阶段复合重建受感染的胸主动脉内膜移植物和邻近的脊柱硬件","authors":"Joseph D. Bozzay MD , Peter J. Kneuertz MD , David S. Xu MD , Timur P. Sarac MD , John Bozinovski MD , Kristine C. Orion MD","doi":"10.1016/j.jvscit.2024.101596","DOIUrl":null,"url":null,"abstract":"<div><p>Thoracic endovascular aortic repair (TEVAR) enables rapid and effective treatment of life-threatening aortic injuries. The occurrence of long-term complications from TEVAR and their management is ill-defined in young patients. This report describes a complex case of a 38-year-old male patient who underwent staged interventions for different acute pathologies instigated by blunt thoracic spinal trauma. The patient was initially treated with a TEVAR for aortic pseudoaneurysm in the setting of infected spinal hardware, which later resulted in an aortobronchial fistula and eroded spinal hardware. This report illustrates a successful multidisciplinary approach for definitive treatment with graft explant and aortic reconstruction.</p></div>","PeriodicalId":45071,"journal":{"name":"Journal of Vascular Surgery Cases Innovations and Techniques","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2024-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2468428724001801/pdfft?md5=6d01b942d7ffb0c21622d715dada9169&pid=1-s2.0-S2468428724001801-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Staged complex reconstruction of infected thoracic aortic endograft and adjacent spinal hardware using latissimus wrapped lateral aortic graft\",\"authors\":\"Joseph D. Bozzay MD , Peter J. Kneuertz MD , David S. Xu MD , Timur P. Sarac MD , John Bozinovski MD , Kristine C. Orion MD\",\"doi\":\"10.1016/j.jvscit.2024.101596\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Thoracic endovascular aortic repair (TEVAR) enables rapid and effective treatment of life-threatening aortic injuries. The occurrence of long-term complications from TEVAR and their management is ill-defined in young patients. This report describes a complex case of a 38-year-old male patient who underwent staged interventions for different acute pathologies instigated by blunt thoracic spinal trauma. The patient was initially treated with a TEVAR for aortic pseudoaneurysm in the setting of infected spinal hardware, which later resulted in an aortobronchial fistula and eroded spinal hardware. This report illustrates a successful multidisciplinary approach for definitive treatment with graft explant and aortic reconstruction.</p></div>\",\"PeriodicalId\":45071,\"journal\":{\"name\":\"Journal of Vascular Surgery Cases Innovations and Techniques\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2468428724001801/pdfft?md5=6d01b942d7ffb0c21622d715dada9169&pid=1-s2.0-S2468428724001801-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Vascular Surgery Cases Innovations and Techniques\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2468428724001801\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vascular Surgery Cases Innovations and Techniques","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468428724001801","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
Staged complex reconstruction of infected thoracic aortic endograft and adjacent spinal hardware using latissimus wrapped lateral aortic graft
Thoracic endovascular aortic repair (TEVAR) enables rapid and effective treatment of life-threatening aortic injuries. The occurrence of long-term complications from TEVAR and their management is ill-defined in young patients. This report describes a complex case of a 38-year-old male patient who underwent staged interventions for different acute pathologies instigated by blunt thoracic spinal trauma. The patient was initially treated with a TEVAR for aortic pseudoaneurysm in the setting of infected spinal hardware, which later resulted in an aortobronchial fistula and eroded spinal hardware. This report illustrates a successful multidisciplinary approach for definitive treatment with graft explant and aortic reconstruction.
期刊介绍:
Journal of Vascular Surgery Cases and Innovative Techniques is a surgical journal dedicated to publishing peer review high quality case reports, vascular images and innovative techniques related to all aspects of arterial, venous, and lymphatic diseases and disorders, including vascular trauma, malformations, wound care and the placement and maintenance of arterio-venous dialysis accesses with an emphasis on the practicing clinician. The Journal seeks to provide novel and timely information to vascular surgeons, interventionalists, phlebologists, wound care specialists, and allied health professionals involved with the management of patients with the entire spectrum of vascular disorders.