Rui Ferreira-Santos, José Pedro Pinto, João Pedro Pinho, Ana Cristina Ribeiro, Maia da Costa, Vicente Vieira, Carmélia Ferreira, Fernando Manso, Joaquim Costa Pereira
{"title":"腹腔镜 Roux-En-Y 胃旁路术后的持续监测:通往非住院护理手术的途径--一项试点研究。","authors":"Rui Ferreira-Santos, José Pedro Pinto, João Pedro Pinho, Ana Cristina Ribeiro, Maia da Costa, Vicente Vieira, Carmélia Ferreira, Fernando Manso, Joaquim Costa Pereira","doi":"10.1007/s10877-024-01216-4","DOIUrl":null,"url":null,"abstract":"<p><p>Same-day discharge (SDD) after Laparoscopic Roux-En-Y Gastric Bypass (LRYGB) faces resistance due to possible undetected postoperative complications. These present with changes in vital signs, which continuous remote monitoring devices can detect. This study compared continuous vital signs monitoring using the Isansys Patient Status Engine™ with standard nursing vital signs measurements to assess the device's reliability in postoperative surveillance of patients undergoing LRYGB. We conducted a pilot study including patients who underwent LRYGB. During their hospital stay, patients were continuously monitored using the Isansys Patient Status Engine™ with Lifetouch™, Lifetemp™, and Nonin Pulse Oximeter™ sensors. The heart rate (HR), body temperature, and oxygen saturation (SpO<sub>2</sub>) collected by the device were compared with standard nursing assessments. Thirteen patients with a mean body mass index of 41.5 ± 4.4 kg/m<sup>2</sup> were included. No major complications occurred. The median HR assessed by standard and continuous monitoring did not significantly differ (75.5 [69-88] vs. 77 [66-91] bpm, p = 0.995), nor did the mean values of SpO<sub>2</sub> (94.7 ± 2.0 vs. 93.7 ± 1.8%, p = 0,057). A significant difference was observed in median body temperature between the nursing staff and the monitoring device (36.3 [36.1-36.7] vs. 36.1 [34.5-36.6] degrees Celsius, p = 0.012), with a tendency for lower temperature measurements by the device. In conclusion, this is the first study on continuous postoperative surveillance using the Isansys Patient Status Engine™ monitoring device for LRYGB patients. Our results introduce a novel tool for more efficient surgery. Prospective randomized experimental studies are warranted to evaluate this method's efficacy and safety.</p>","PeriodicalId":15513,"journal":{"name":"Journal of Clinical Monitoring and Computing","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Continuous monitoring after laparoscopic Roux-En-Y gastric bypass: a pathway to ambulatory care surgery - a pilot study.\",\"authors\":\"Rui Ferreira-Santos, José Pedro Pinto, João Pedro Pinho, Ana Cristina Ribeiro, Maia da Costa, Vicente Vieira, Carmélia Ferreira, Fernando Manso, Joaquim Costa Pereira\",\"doi\":\"10.1007/s10877-024-01216-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Same-day discharge (SDD) after Laparoscopic Roux-En-Y Gastric Bypass (LRYGB) faces resistance due to possible undetected postoperative complications. These present with changes in vital signs, which continuous remote monitoring devices can detect. This study compared continuous vital signs monitoring using the Isansys Patient Status Engine™ with standard nursing vital signs measurements to assess the device's reliability in postoperative surveillance of patients undergoing LRYGB. We conducted a pilot study including patients who underwent LRYGB. During their hospital stay, patients were continuously monitored using the Isansys Patient Status Engine™ with Lifetouch™, Lifetemp™, and Nonin Pulse Oximeter™ sensors. The heart rate (HR), body temperature, and oxygen saturation (SpO<sub>2</sub>) collected by the device were compared with standard nursing assessments. Thirteen patients with a mean body mass index of 41.5 ± 4.4 kg/m<sup>2</sup> were included. No major complications occurred. The median HR assessed by standard and continuous monitoring did not significantly differ (75.5 [69-88] vs. 77 [66-91] bpm, p = 0.995), nor did the mean values of SpO<sub>2</sub> (94.7 ± 2.0 vs. 93.7 ± 1.8%, p = 0,057). A significant difference was observed in median body temperature between the nursing staff and the monitoring device (36.3 [36.1-36.7] vs. 36.1 [34.5-36.6] degrees Celsius, p = 0.012), with a tendency for lower temperature measurements by the device. In conclusion, this is the first study on continuous postoperative surveillance using the Isansys Patient Status Engine™ monitoring device for LRYGB patients. Our results introduce a novel tool for more efficient surgery. Prospective randomized experimental studies are warranted to evaluate this method's efficacy and safety.</p>\",\"PeriodicalId\":15513,\"journal\":{\"name\":\"Journal of Clinical Monitoring and Computing\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-09-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Monitoring and Computing\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10877-024-01216-4\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Monitoring and Computing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10877-024-01216-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
Continuous monitoring after laparoscopic Roux-En-Y gastric bypass: a pathway to ambulatory care surgery - a pilot study.
Same-day discharge (SDD) after Laparoscopic Roux-En-Y Gastric Bypass (LRYGB) faces resistance due to possible undetected postoperative complications. These present with changes in vital signs, which continuous remote monitoring devices can detect. This study compared continuous vital signs monitoring using the Isansys Patient Status Engine™ with standard nursing vital signs measurements to assess the device's reliability in postoperative surveillance of patients undergoing LRYGB. We conducted a pilot study including patients who underwent LRYGB. During their hospital stay, patients were continuously monitored using the Isansys Patient Status Engine™ with Lifetouch™, Lifetemp™, and Nonin Pulse Oximeter™ sensors. The heart rate (HR), body temperature, and oxygen saturation (SpO2) collected by the device were compared with standard nursing assessments. Thirteen patients with a mean body mass index of 41.5 ± 4.4 kg/m2 were included. No major complications occurred. The median HR assessed by standard and continuous monitoring did not significantly differ (75.5 [69-88] vs. 77 [66-91] bpm, p = 0.995), nor did the mean values of SpO2 (94.7 ± 2.0 vs. 93.7 ± 1.8%, p = 0,057). A significant difference was observed in median body temperature between the nursing staff and the monitoring device (36.3 [36.1-36.7] vs. 36.1 [34.5-36.6] degrees Celsius, p = 0.012), with a tendency for lower temperature measurements by the device. In conclusion, this is the first study on continuous postoperative surveillance using the Isansys Patient Status Engine™ monitoring device for LRYGB patients. Our results introduce a novel tool for more efficient surgery. Prospective randomized experimental studies are warranted to evaluate this method's efficacy and safety.
期刊介绍:
The Journal of Clinical Monitoring and Computing is a clinical journal publishing papers related to technology in the fields of anaesthesia, intensive care medicine, emergency medicine, and peri-operative medicine.
The journal has links with numerous specialist societies, including editorial board representatives from the European Society for Computing and Technology in Anaesthesia and Intensive Care (ESCTAIC), the Society for Technology in Anesthesia (STA), the Society for Complex Acute Illness (SCAI) and the NAVAt (NAVigating towards your Anaestheisa Targets) group.
The journal publishes original papers, narrative and systematic reviews, technological notes, letters to the editor, editorial or commentary papers, and policy statements or guidelines from national or international societies. The journal encourages debate on published papers and technology, including letters commenting on previous publications or technological concerns. The journal occasionally publishes special issues with technological or clinical themes, or reports and abstracts from scientificmeetings. Special issues proposals should be sent to the Editor-in-Chief. Specific details of types of papers, and the clinical and technological content of papers considered within scope can be found in instructions for authors.