Luke A Stangler, Su-Youne Chang, Inyong Kim, Jonghoon Choi, Abbas Z Kouzani, Kevin E. Bennet, Terry C Burns, Jamie J Van Gompel, Gregory A Worrell and Charles L Howe*,
{"title":"确定基于微灌注的脑实质取样过程中分析物恢复的空间分辨率","authors":"Luke A Stangler, Su-Youne Chang, Inyong Kim, Jonghoon Choi, Abbas Z Kouzani, Kevin E. Bennet, Terry C Burns, Jamie J Van Gompel, Gregory A Worrell and Charles L Howe*, ","doi":"10.1021/acschemneuro.4c0041010.1021/acschemneuro.4c00410","DOIUrl":null,"url":null,"abstract":"<p >The unique architecture of the brain and the blood-brain barrier imposes challenges for the measurement of parenchyma-derived biomarkers that prevent sufficient understanding of transient neuropathogenic processes. One solution to this challenge is direct sampling of brain interstitial fluid via implanted microperfusion probes. Seeking to understand spatial limitations to microperfusion in the brain, we employed computational fluid dynamics modeling and empirical recovery of fluorescently labeled dextrans in an animal model. We found that dextrans were successfully recovered via microperfusion over a 6 h sampling period, especially at probes implanted 2 mm from the dextran infusion point relative to probes implanted 5 mm from the injection site. Experimental recovery was consistently around 1% of simulated, suggesting that this parameter can be used to set practical limits on the maximal tissue concentration of proteins measured in microperfusates and on the spatial domain sampled by our multimodal microperfusion probe.</p>","PeriodicalId":13,"journal":{"name":"ACS Chemical Neuroscience","volume":null,"pages":null},"PeriodicalIF":4.1000,"publicationDate":"2024-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.acs.org/doi/epdf/10.1021/acschemneuro.4c00410","citationCount":"0","resultStr":"{\"title\":\"Defining the Spatial Resolution of Analyte Recovery during Microperfusion-Based Sampling of Brain Parenchyma\",\"authors\":\"Luke A Stangler, Su-Youne Chang, Inyong Kim, Jonghoon Choi, Abbas Z Kouzani, Kevin E. Bennet, Terry C Burns, Jamie J Van Gompel, Gregory A Worrell and Charles L Howe*, \",\"doi\":\"10.1021/acschemneuro.4c0041010.1021/acschemneuro.4c00410\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >The unique architecture of the brain and the blood-brain barrier imposes challenges for the measurement of parenchyma-derived biomarkers that prevent sufficient understanding of transient neuropathogenic processes. One solution to this challenge is direct sampling of brain interstitial fluid via implanted microperfusion probes. Seeking to understand spatial limitations to microperfusion in the brain, we employed computational fluid dynamics modeling and empirical recovery of fluorescently labeled dextrans in an animal model. We found that dextrans were successfully recovered via microperfusion over a 6 h sampling period, especially at probes implanted 2 mm from the dextran infusion point relative to probes implanted 5 mm from the injection site. Experimental recovery was consistently around 1% of simulated, suggesting that this parameter can be used to set practical limits on the maximal tissue concentration of proteins measured in microperfusates and on the spatial domain sampled by our multimodal microperfusion probe.</p>\",\"PeriodicalId\":13,\"journal\":{\"name\":\"ACS Chemical Neuroscience\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2024-08-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://pubs.acs.org/doi/epdf/10.1021/acschemneuro.4c00410\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Chemical Neuroscience\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://pubs.acs.org/doi/10.1021/acschemneuro.4c00410\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Chemical Neuroscience","FirstCategoryId":"3","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acschemneuro.4c00410","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
Defining the Spatial Resolution of Analyte Recovery during Microperfusion-Based Sampling of Brain Parenchyma
The unique architecture of the brain and the blood-brain barrier imposes challenges for the measurement of parenchyma-derived biomarkers that prevent sufficient understanding of transient neuropathogenic processes. One solution to this challenge is direct sampling of brain interstitial fluid via implanted microperfusion probes. Seeking to understand spatial limitations to microperfusion in the brain, we employed computational fluid dynamics modeling and empirical recovery of fluorescently labeled dextrans in an animal model. We found that dextrans were successfully recovered via microperfusion over a 6 h sampling period, especially at probes implanted 2 mm from the dextran infusion point relative to probes implanted 5 mm from the injection site. Experimental recovery was consistently around 1% of simulated, suggesting that this parameter can be used to set practical limits on the maximal tissue concentration of proteins measured in microperfusates and on the spatial domain sampled by our multimodal microperfusion probe.
期刊介绍:
ACS Chemical Neuroscience publishes high-quality research articles and reviews that showcase chemical, quantitative biological, biophysical and bioengineering approaches to the understanding of the nervous system and to the development of new treatments for neurological disorders. Research in the journal focuses on aspects of chemical neurobiology and bio-neurochemistry such as the following:
Neurotransmitters and receptors
Neuropharmaceuticals and therapeutics
Neural development—Plasticity, and degeneration
Chemical, physical, and computational methods in neuroscience
Neuronal diseases—basis, detection, and treatment
Mechanism of aging, learning, memory and behavior
Pain and sensory processing
Neurotoxins
Neuroscience-inspired bioengineering
Development of methods in chemical neurobiology
Neuroimaging agents and technologies
Animal models for central nervous system diseases
Behavioral research