用于 225Ac 生产车间放射性核素纯度测试的简化阿尔法光谱仪的能量分辨率改进。

Pub Date : 2024-09-19 DOI:10.1093/rpd/ncae185
Yuma Mihei, Kotaro Tani, Jun Ichinose, Kotaro Nagatsu, Masahiro Fukushi, Osamu Kurihara, Kazumasa Inoue
{"title":"用于 225Ac 生产车间放射性核素纯度测试的简化阿尔法光谱仪的能量分辨率改进。","authors":"Yuma Mihei, Kotaro Tani, Jun Ichinose, Kotaro Nagatsu, Masahiro Fukushi, Osamu Kurihara, Kazumasa Inoue","doi":"10.1093/rpd/ncae185","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigated the feasibility of a simplified method of alpha spectroscopy for radionuclidic purity tests at 225Ac production sites that eliminates the need for a vacuum chamber. The impact of enhancing the energy resolution using a collimator was evaluated through radiation transport simulations. The results showed that a full width at tenth maximum (FWTM) of <300 keV was achieved for alpha particles from 241Am, for which the main energy peak was 5.5 MeV. Experimental validation using an electrodeposition source containing 237Np, 241Am, and 244Cm confirmed an FWTM of 272 keV for both 241Am and 244Cm. These two peaks, with a difference of ~300 keV, were effectively separated. In response to the growing demand for targeted radioisotope therapy, this simplified alpha spectroscopy method offers the potential to detect 226Ra mixed with 225Ac generated by accelerators, given the alpha energy difference of ~700 keV.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Energy resolution improvement in simplified alpha spectroscopy for radionuclidic purity tests on 225Ac production floors.\",\"authors\":\"Yuma Mihei, Kotaro Tani, Jun Ichinose, Kotaro Nagatsu, Masahiro Fukushi, Osamu Kurihara, Kazumasa Inoue\",\"doi\":\"10.1093/rpd/ncae185\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study investigated the feasibility of a simplified method of alpha spectroscopy for radionuclidic purity tests at 225Ac production sites that eliminates the need for a vacuum chamber. The impact of enhancing the energy resolution using a collimator was evaluated through radiation transport simulations. The results showed that a full width at tenth maximum (FWTM) of <300 keV was achieved for alpha particles from 241Am, for which the main energy peak was 5.5 MeV. Experimental validation using an electrodeposition source containing 237Np, 241Am, and 244Cm confirmed an FWTM of 272 keV for both 241Am and 244Cm. These two peaks, with a difference of ~300 keV, were effectively separated. In response to the growing demand for targeted radioisotope therapy, this simplified alpha spectroscopy method offers the potential to detect 226Ra mixed with 225Ac generated by accelerators, given the alpha energy difference of ~700 keV.</p>\",\"PeriodicalId\":0,\"journal\":{\"name\":\"\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0,\"publicationDate\":\"2024-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1093/rpd/ncae185\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncae185","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

这项研究调查了在 225Ac 生产基地进行放射性核素纯度测试时采用一种无需真空室的简化阿尔法光谱法的可行性。通过辐射传输模拟评估了使用准直器提高能量分辨率的影响。结果表明,十分之一最大值的全宽(FWTM)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享
查看原文
Energy resolution improvement in simplified alpha spectroscopy for radionuclidic purity tests on 225Ac production floors.

This study investigated the feasibility of a simplified method of alpha spectroscopy for radionuclidic purity tests at 225Ac production sites that eliminates the need for a vacuum chamber. The impact of enhancing the energy resolution using a collimator was evaluated through radiation transport simulations. The results showed that a full width at tenth maximum (FWTM) of <300 keV was achieved for alpha particles from 241Am, for which the main energy peak was 5.5 MeV. Experimental validation using an electrodeposition source containing 237Np, 241Am, and 244Cm confirmed an FWTM of 272 keV for both 241Am and 244Cm. These two peaks, with a difference of ~300 keV, were effectively separated. In response to the growing demand for targeted radioisotope therapy, this simplified alpha spectroscopy method offers the potential to detect 226Ra mixed with 225Ac generated by accelerators, given the alpha energy difference of ~700 keV.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信