Clément Haddadi , Antoine Kimmoun , Marine Jacquier , Bruno Megarbane , Nicolas Deye , Bruno Levy
{"title":"关于法国重症监护病房心脏骤停后护理和体温管理最新变化的实践调查","authors":"Clément Haddadi , Antoine Kimmoun , Marine Jacquier , Bruno Megarbane , Nicolas Deye , Bruno Levy","doi":"10.1016/j.jcrc.2024.154903","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Recent guidelines for post-cardiac arrest (CA) management have undergone significant changes regarding targeted therapeutic management (TTM), transitioning from hypothermia to temperature control. We aimed to assess changes in post-CA management in French intensive care units following the new recommendations.</p></div><div><h3>Methods</h3><p>Two declarative web surveys were conducted from March to August 2023. We compared the doctors' survey to that previously published in 2015. We contacted 389 departments from 276 French centers.</p></div><div><h3>Results</h3><p>Three hundred thirty-four physicians from 189 distinct ICUs departments participated in the survey. TTM was used by 95.5 % of respondents. TTM with temperature feedback device was used by 64 % of respondents. In multivariate analysis, use of TTM with temperature feedback was associated with university hospital responder [OR 1.99 (1.19–3.34, <em>p</em> = 0.009)], high CA admissions rate [OR 2.25 (1.13–4.78, <em>p</em> = 0.026)], use of a written CA procedure [OR 1.76 (1.07–2.92, <em>p</em> = 0.027)] and presence of a cath-lab performing coronary angiography [OR 2.42 (1.33–4.44, <em>p</em> = 0.004)]. The targeted temperature rose from 32 to 34 °C in 2015, to 35–36 °C in 2023 (<em>p</em> < 0.001). Proportions of TTM with temperature feedback devices switched from 45 % to 65 % (p < 0.001). 660 nurses responses from 150 ICUs were analyzed. According to TTM users, gel-coated water circulating pads and intravascular cooling were considered the most effective devices and were found to be easily adjustable.</p></div><div><h3>Conclusions</h3><p>These surveys provide insights into post-resuscitation care and TTM practice in France. One year after their publication, the latest recommendations concerning TTM have not been fully implemented, as the majority of ICUs continue to use moderate hypothermia. They widely reported employing specific TTM, with the use of TTM with temperature feedback devices increasing significantly. Heterogeneity exists regarding the TTM systems used, with a significant proportion lacking temperature feedback. This aspect requires specific attention, depending on local constraints and devices costs.</p></div>","PeriodicalId":15451,"journal":{"name":"Journal of critical care","volume":"84 ","pages":"Article 154903"},"PeriodicalIF":3.2000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Practice survey on recent changes in post cardiac arrest care and temperature management in French intensive care units\",\"authors\":\"Clément Haddadi , Antoine Kimmoun , Marine Jacquier , Bruno Megarbane , Nicolas Deye , Bruno Levy\",\"doi\":\"10.1016/j.jcrc.2024.154903\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Recent guidelines for post-cardiac arrest (CA) management have undergone significant changes regarding targeted therapeutic management (TTM), transitioning from hypothermia to temperature control. We aimed to assess changes in post-CA management in French intensive care units following the new recommendations.</p></div><div><h3>Methods</h3><p>Two declarative web surveys were conducted from March to August 2023. We compared the doctors' survey to that previously published in 2015. We contacted 389 departments from 276 French centers.</p></div><div><h3>Results</h3><p>Three hundred thirty-four physicians from 189 distinct ICUs departments participated in the survey. TTM was used by 95.5 % of respondents. TTM with temperature feedback device was used by 64 % of respondents. In multivariate analysis, use of TTM with temperature feedback was associated with university hospital responder [OR 1.99 (1.19–3.34, <em>p</em> = 0.009)], high CA admissions rate [OR 2.25 (1.13–4.78, <em>p</em> = 0.026)], use of a written CA procedure [OR 1.76 (1.07–2.92, <em>p</em> = 0.027)] and presence of a cath-lab performing coronary angiography [OR 2.42 (1.33–4.44, <em>p</em> = 0.004)]. The targeted temperature rose from 32 to 34 °C in 2015, to 35–36 °C in 2023 (<em>p</em> < 0.001). Proportions of TTM with temperature feedback devices switched from 45 % to 65 % (p < 0.001). 660 nurses responses from 150 ICUs were analyzed. According to TTM users, gel-coated water circulating pads and intravascular cooling were considered the most effective devices and were found to be easily adjustable.</p></div><div><h3>Conclusions</h3><p>These surveys provide insights into post-resuscitation care and TTM practice in France. One year after their publication, the latest recommendations concerning TTM have not been fully implemented, as the majority of ICUs continue to use moderate hypothermia. They widely reported employing specific TTM, with the use of TTM with temperature feedback devices increasing significantly. Heterogeneity exists regarding the TTM systems used, with a significant proportion lacking temperature feedback. This aspect requires specific attention, depending on local constraints and devices costs.</p></div>\",\"PeriodicalId\":15451,\"journal\":{\"name\":\"Journal of critical care\",\"volume\":\"84 \",\"pages\":\"Article 154903\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of critical care\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0883944124003903\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CRITICAL CARE MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of critical care","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0883944124003903","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
Practice survey on recent changes in post cardiac arrest care and temperature management in French intensive care units
Background
Recent guidelines for post-cardiac arrest (CA) management have undergone significant changes regarding targeted therapeutic management (TTM), transitioning from hypothermia to temperature control. We aimed to assess changes in post-CA management in French intensive care units following the new recommendations.
Methods
Two declarative web surveys were conducted from March to August 2023. We compared the doctors' survey to that previously published in 2015. We contacted 389 departments from 276 French centers.
Results
Three hundred thirty-four physicians from 189 distinct ICUs departments participated in the survey. TTM was used by 95.5 % of respondents. TTM with temperature feedback device was used by 64 % of respondents. In multivariate analysis, use of TTM with temperature feedback was associated with university hospital responder [OR 1.99 (1.19–3.34, p = 0.009)], high CA admissions rate [OR 2.25 (1.13–4.78, p = 0.026)], use of a written CA procedure [OR 1.76 (1.07–2.92, p = 0.027)] and presence of a cath-lab performing coronary angiography [OR 2.42 (1.33–4.44, p = 0.004)]. The targeted temperature rose from 32 to 34 °C in 2015, to 35–36 °C in 2023 (p < 0.001). Proportions of TTM with temperature feedback devices switched from 45 % to 65 % (p < 0.001). 660 nurses responses from 150 ICUs were analyzed. According to TTM users, gel-coated water circulating pads and intravascular cooling were considered the most effective devices and were found to be easily adjustable.
Conclusions
These surveys provide insights into post-resuscitation care and TTM practice in France. One year after their publication, the latest recommendations concerning TTM have not been fully implemented, as the majority of ICUs continue to use moderate hypothermia. They widely reported employing specific TTM, with the use of TTM with temperature feedback devices increasing significantly. Heterogeneity exists regarding the TTM systems used, with a significant proportion lacking temperature feedback. This aspect requires specific attention, depending on local constraints and devices costs.
期刊介绍:
The Journal of Critical Care, the official publication of the World Federation of Societies of Intensive and Critical Care Medicine (WFSICCM), is a leading international, peer-reviewed journal providing original research, review articles, tutorials, and invited articles for physicians and allied health professionals involved in treating the critically ill. The Journal aims to improve patient care by furthering understanding of health systems research and its integration into clinical practice.
The Journal will include articles which discuss:
All aspects of health services research in critical care
System based practice in anesthesiology, perioperative and critical care medicine
The interface between anesthesiology, critical care medicine and pain
Integrating intraoperative management in preparation for postoperative critical care management and recovery
Optimizing patient management, i.e., exploring the interface between evidence-based principles or clinical insight into management and care of complex patients
The team approach in the OR and ICU
System-based research
Medical ethics
Technology in medicine
Seminars discussing current, state of the art, and sometimes controversial topics in anesthesiology, critical care medicine, and professional education
Residency Education.