Ricardo Castro , Pablo Born , Eric Roessler , Christian Labra , Paul McNab , Sebastián Bravo , Dagoberto Soto , Eduardo Kattan , Glenn Hernández , Jan Bakker
{"title":"在体液超负荷的机械通气患者中以前负荷反应为指导进行液体清除:临床生理学综合研究","authors":"Ricardo Castro , Pablo Born , Eric Roessler , Christian Labra , Paul McNab , Sebastián Bravo , Dagoberto Soto , Eduardo Kattan , Glenn Hernández , Jan Bakker","doi":"10.1016/j.jcrc.2024.154901","DOIUrl":null,"url":null,"abstract":"<div><p>This study investigated fluid removal strategies for critically ill patients with fluid overload on mechanical ventilation. Traditionally, a negative fluid balance (FB) is aimed for. However, this approach can have drawbacks. Here, we compared a new approach, namely removing fluids until patients become fluid responsive (FR) to the traditional empiric negative balance approach.</p><p>Twelve patients were placed in each group (<em>n</em> = 24). FR assessment was performed using passive leg raising (PLR). Both groups maintained stable blood pressure and heart function during fluid management. Notably, the FR group weaned from the ventilator significantly faster than negative FB group (both for a spontaneous breathing trial (14 h vs. 36 h, <em>p</em> = 0.031) and extubation (26 h vs. 57 h, <em>p</em> = 0.007); the difference in total ventilator time wasn't statistically significant (49 h vs. 62 h, <em>p</em> = 0.065). Additionally, FR group avoided metabolic problems like secondary alkalosis and potential hypokalemia seen in the negative FB group.</p><p>FR-guided fluid-removal in fluid overloaded mechanically ventilated patients was a feasible, safe, and maybe superior strategy in facilitating weaning and disconnection from mechanical ventilation than negative FB-driven fluid removal. FR is a safe endpoint for optimizing cardiac function and preventing adverse consequences during fluid removal.</p></div>","PeriodicalId":15451,"journal":{"name":"Journal of critical care","volume":"84 ","pages":"Article 154901"},"PeriodicalIF":3.2000,"publicationDate":"2024-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preload responsiveness–guided fluid removal in mechanically ventilated patients with fluid overload: A comprehensive clinical–physiological study\",\"authors\":\"Ricardo Castro , Pablo Born , Eric Roessler , Christian Labra , Paul McNab , Sebastián Bravo , Dagoberto Soto , Eduardo Kattan , Glenn Hernández , Jan Bakker\",\"doi\":\"10.1016/j.jcrc.2024.154901\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This study investigated fluid removal strategies for critically ill patients with fluid overload on mechanical ventilation. Traditionally, a negative fluid balance (FB) is aimed for. However, this approach can have drawbacks. Here, we compared a new approach, namely removing fluids until patients become fluid responsive (FR) to the traditional empiric negative balance approach.</p><p>Twelve patients were placed in each group (<em>n</em> = 24). FR assessment was performed using passive leg raising (PLR). Both groups maintained stable blood pressure and heart function during fluid management. Notably, the FR group weaned from the ventilator significantly faster than negative FB group (both for a spontaneous breathing trial (14 h vs. 36 h, <em>p</em> = 0.031) and extubation (26 h vs. 57 h, <em>p</em> = 0.007); the difference in total ventilator time wasn't statistically significant (49 h vs. 62 h, <em>p</em> = 0.065). Additionally, FR group avoided metabolic problems like secondary alkalosis and potential hypokalemia seen in the negative FB group.</p><p>FR-guided fluid-removal in fluid overloaded mechanically ventilated patients was a feasible, safe, and maybe superior strategy in facilitating weaning and disconnection from mechanical ventilation than negative FB-driven fluid removal. FR is a safe endpoint for optimizing cardiac function and preventing adverse consequences during fluid removal.</p></div>\",\"PeriodicalId\":15451,\"journal\":{\"name\":\"Journal of critical care\",\"volume\":\"84 \",\"pages\":\"Article 154901\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-08-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of critical care\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0883944124003885\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CRITICAL CARE MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of critical care","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0883944124003885","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
Preload responsiveness–guided fluid removal in mechanically ventilated patients with fluid overload: A comprehensive clinical–physiological study
This study investigated fluid removal strategies for critically ill patients with fluid overload on mechanical ventilation. Traditionally, a negative fluid balance (FB) is aimed for. However, this approach can have drawbacks. Here, we compared a new approach, namely removing fluids until patients become fluid responsive (FR) to the traditional empiric negative balance approach.
Twelve patients were placed in each group (n = 24). FR assessment was performed using passive leg raising (PLR). Both groups maintained stable blood pressure and heart function during fluid management. Notably, the FR group weaned from the ventilator significantly faster than negative FB group (both for a spontaneous breathing trial (14 h vs. 36 h, p = 0.031) and extubation (26 h vs. 57 h, p = 0.007); the difference in total ventilator time wasn't statistically significant (49 h vs. 62 h, p = 0.065). Additionally, FR group avoided metabolic problems like secondary alkalosis and potential hypokalemia seen in the negative FB group.
FR-guided fluid-removal in fluid overloaded mechanically ventilated patients was a feasible, safe, and maybe superior strategy in facilitating weaning and disconnection from mechanical ventilation than negative FB-driven fluid removal. FR is a safe endpoint for optimizing cardiac function and preventing adverse consequences during fluid removal.
期刊介绍:
The Journal of Critical Care, the official publication of the World Federation of Societies of Intensive and Critical Care Medicine (WFSICCM), is a leading international, peer-reviewed journal providing original research, review articles, tutorials, and invited articles for physicians and allied health professionals involved in treating the critically ill. The Journal aims to improve patient care by furthering understanding of health systems research and its integration into clinical practice.
The Journal will include articles which discuss:
All aspects of health services research in critical care
System based practice in anesthesiology, perioperative and critical care medicine
The interface between anesthesiology, critical care medicine and pain
Integrating intraoperative management in preparation for postoperative critical care management and recovery
Optimizing patient management, i.e., exploring the interface between evidence-based principles or clinical insight into management and care of complex patients
The team approach in the OR and ICU
System-based research
Medical ethics
Technology in medicine
Seminars discussing current, state of the art, and sometimes controversial topics in anesthesiology, critical care medicine, and professional education
Residency Education.