Audrey I Marlar, Bradley K Knabe, Yasamin Taghikhan, Richard L Applegate, Neal W Fleming
{"title":"脉搏血氧仪的性能与种族和皮肤色素沉着的关系:一项单中心回顾性研究。","authors":"Audrey I Marlar, Bradley K Knabe, Yasamin Taghikhan, Richard L Applegate, Neal W Fleming","doi":"10.1007/s10877-024-01211-9","DOIUrl":null,"url":null,"abstract":"<p><p>Pulse oximetry (SpO<sub>2</sub>) is a critical monitor for assessing oxygenation status and guiding therapy in critically ill patients. Race has been identified as a potential source of SpO<sub>2</sub> error, with consequent bias and inequities in healthcare. This study was designed to evaluate the incidence of occult hypoxemia and accuracy of pulse oximetry associated with the Massey-Martin scale and characterize the relationship between Massey scores and self-identified race. This retrospective single institute study utilized the Massey-Martin scale as a quantitative assessment of skin pigmentation. These values were recorded peri-operatively in patients enrolled in unrelated clinical trials. The electronic medical record was utilized to obtain demographics, arterial blood gas values, and time matched SpO<sub>2</sub> values for each PaO<sub>2</sub> ≤ 125 mmHg recorded throughout their hospitalizations. Differences between SaO<sub>2</sub> and SpO<sub>2</sub> were compared as a function of both Massey score and self-reported race. 4030 paired SaO<sub>2</sub>-SpO<sub>2</sub> values were available from 579 patients. The average error (SaO<sub>2</sub>-SpO<sub>2</sub>) ± SD was 0.23 ± 2.6%. Statistically significant differences were observed within Massey scores and among races, with average errors that ranged from - 0.39 ± 2.3 to 0.53 ± 2.5 and - 0.55 ± 2.1 to 0.37 ± 2.7, respectively. Skin color varied widely within each self-identified race category. There was no clinically significant association between error rates and Massey-Martin scale grades and no clinically significant difference in accuracy observed between self-reported Black and White patients. In addition, self-reported race is not an appropriate surrogate for skin color.</p>","PeriodicalId":15513,"journal":{"name":"Journal of Clinical Monitoring and Computing","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance of pulse oximeters as a function of race compared to skin pigmentation: a single center retrospective study.\",\"authors\":\"Audrey I Marlar, Bradley K Knabe, Yasamin Taghikhan, Richard L Applegate, Neal W Fleming\",\"doi\":\"10.1007/s10877-024-01211-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Pulse oximetry (SpO<sub>2</sub>) is a critical monitor for assessing oxygenation status and guiding therapy in critically ill patients. Race has been identified as a potential source of SpO<sub>2</sub> error, with consequent bias and inequities in healthcare. This study was designed to evaluate the incidence of occult hypoxemia and accuracy of pulse oximetry associated with the Massey-Martin scale and characterize the relationship between Massey scores and self-identified race. This retrospective single institute study utilized the Massey-Martin scale as a quantitative assessment of skin pigmentation. These values were recorded peri-operatively in patients enrolled in unrelated clinical trials. The electronic medical record was utilized to obtain demographics, arterial blood gas values, and time matched SpO<sub>2</sub> values for each PaO<sub>2</sub> ≤ 125 mmHg recorded throughout their hospitalizations. Differences between SaO<sub>2</sub> and SpO<sub>2</sub> were compared as a function of both Massey score and self-reported race. 4030 paired SaO<sub>2</sub>-SpO<sub>2</sub> values were available from 579 patients. The average error (SaO<sub>2</sub>-SpO<sub>2</sub>) ± SD was 0.23 ± 2.6%. Statistically significant differences were observed within Massey scores and among races, with average errors that ranged from - 0.39 ± 2.3 to 0.53 ± 2.5 and - 0.55 ± 2.1 to 0.37 ± 2.7, respectively. Skin color varied widely within each self-identified race category. There was no clinically significant association between error rates and Massey-Martin scale grades and no clinically significant difference in accuracy observed between self-reported Black and White patients. In addition, self-reported race is not an appropriate surrogate for skin color.</p>\",\"PeriodicalId\":15513,\"journal\":{\"name\":\"Journal of Clinical Monitoring and Computing\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-08-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Monitoring and Computing\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10877-024-01211-9\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Monitoring and Computing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10877-024-01211-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
Performance of pulse oximeters as a function of race compared to skin pigmentation: a single center retrospective study.
Pulse oximetry (SpO2) is a critical monitor for assessing oxygenation status and guiding therapy in critically ill patients. Race has been identified as a potential source of SpO2 error, with consequent bias and inequities in healthcare. This study was designed to evaluate the incidence of occult hypoxemia and accuracy of pulse oximetry associated with the Massey-Martin scale and characterize the relationship between Massey scores and self-identified race. This retrospective single institute study utilized the Massey-Martin scale as a quantitative assessment of skin pigmentation. These values were recorded peri-operatively in patients enrolled in unrelated clinical trials. The electronic medical record was utilized to obtain demographics, arterial blood gas values, and time matched SpO2 values for each PaO2 ≤ 125 mmHg recorded throughout their hospitalizations. Differences between SaO2 and SpO2 were compared as a function of both Massey score and self-reported race. 4030 paired SaO2-SpO2 values were available from 579 patients. The average error (SaO2-SpO2) ± SD was 0.23 ± 2.6%. Statistically significant differences were observed within Massey scores and among races, with average errors that ranged from - 0.39 ± 2.3 to 0.53 ± 2.5 and - 0.55 ± 2.1 to 0.37 ± 2.7, respectively. Skin color varied widely within each self-identified race category. There was no clinically significant association between error rates and Massey-Martin scale grades and no clinically significant difference in accuracy observed between self-reported Black and White patients. In addition, self-reported race is not an appropriate surrogate for skin color.
期刊介绍:
The Journal of Clinical Monitoring and Computing is a clinical journal publishing papers related to technology in the fields of anaesthesia, intensive care medicine, emergency medicine, and peri-operative medicine.
The journal has links with numerous specialist societies, including editorial board representatives from the European Society for Computing and Technology in Anaesthesia and Intensive Care (ESCTAIC), the Society for Technology in Anesthesia (STA), the Society for Complex Acute Illness (SCAI) and the NAVAt (NAVigating towards your Anaestheisa Targets) group.
The journal publishes original papers, narrative and systematic reviews, technological notes, letters to the editor, editorial or commentary papers, and policy statements or guidelines from national or international societies. The journal encourages debate on published papers and technology, including letters commenting on previous publications or technological concerns. The journal occasionally publishes special issues with technological or clinical themes, or reports and abstracts from scientificmeetings. Special issues proposals should be sent to the Editor-in-Chief. Specific details of types of papers, and the clinical and technological content of papers considered within scope can be found in instructions for authors.