桡骨远端骨折手术中的术中透视技能:在新型沉浸式虚拟现实模拟器上进行有效可靠的评估。

IF 2.5 2区 医学 Q1 ORTHOPEDICS
Marie Sønderup, Amandus Gustafsson, Lars Konge, Mads Emil Jacobsen
{"title":"桡骨远端骨折手术中的术中透视技能:在新型沉浸式虚拟现实模拟器上进行有效可靠的评估。","authors":"Marie Sønderup, Amandus Gustafsson, Lars Konge, Mads Emil Jacobsen","doi":"10.2340/17453674.2024.41345","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong> Orthopedic trainees must be able to perform intraoperative fluoroscopy imaging to assess the surgical result after volar locking plate surgeries of distal radius fractures. Guided by Messick's contemporary validity framework, the aim of our study was to gather evidence of validity for a test of proficiency for intraoperative imaging of a distal radius fracture using a novel immersive virtual reality simulator.</p><p><strong>Methods: </strong> 11 novices and 9 experienced surgeons employed at orthopedic departments completed 2 individual simulator sessions. At each session the participants performed 3 repetitions of an intraoperative fluoroscopic control of a distal radius fracture, consisting of 5 different fluoroscopic views. Several performance metrics were automatically recorded by the simulator and compared between the 2 groups.</p><p><strong>Results: </strong> Simulator metrics for 3 of the 5 fluoroscopic views could discriminate between novices and experienced surgeons. An estimated composite score based on these 3 views showed good test-retest reliability, ICC = 0.82 (confidence interval 0.65-0.92; P < 0.001). A discriminatory standard was set at a composite score of 6.15 points resulting in 1 false positive (i.e., novice scoring better than the standard), and 1 false negative (i.e., experienced surgeon scoring worse than the standard).</p><p><strong>Conclusion: </strong> This study provided validity evidence from all 5 sources of Messick's contemporary validity framework (content, response process, internal structure, relationship with other variables, and consequences) for a simulation-based test of proficiency in intraoperative fluoroscopic control of a distal radius fracture fixated by a volar locking plate.</p>","PeriodicalId":6916,"journal":{"name":"Acta Orthopaedica","volume":"95 ","pages":"477-484"},"PeriodicalIF":2.5000,"publicationDate":"2024-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11350966/pdf/","citationCount":"0","resultStr":"{\"title\":\"Intraoperative fluoroscopy skills in distal radius fracture surgery: valid and reliable assessment on a novel immersive virtual reality simulator.\",\"authors\":\"Marie Sønderup, Amandus Gustafsson, Lars Konge, Mads Emil Jacobsen\",\"doi\":\"10.2340/17453674.2024.41345\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and purpose: </strong> Orthopedic trainees must be able to perform intraoperative fluoroscopy imaging to assess the surgical result after volar locking plate surgeries of distal radius fractures. Guided by Messick's contemporary validity framework, the aim of our study was to gather evidence of validity for a test of proficiency for intraoperative imaging of a distal radius fracture using a novel immersive virtual reality simulator.</p><p><strong>Methods: </strong> 11 novices and 9 experienced surgeons employed at orthopedic departments completed 2 individual simulator sessions. At each session the participants performed 3 repetitions of an intraoperative fluoroscopic control of a distal radius fracture, consisting of 5 different fluoroscopic views. Several performance metrics were automatically recorded by the simulator and compared between the 2 groups.</p><p><strong>Results: </strong> Simulator metrics for 3 of the 5 fluoroscopic views could discriminate between novices and experienced surgeons. An estimated composite score based on these 3 views showed good test-retest reliability, ICC = 0.82 (confidence interval 0.65-0.92; P < 0.001). A discriminatory standard was set at a composite score of 6.15 points resulting in 1 false positive (i.e., novice scoring better than the standard), and 1 false negative (i.e., experienced surgeon scoring worse than the standard).</p><p><strong>Conclusion: </strong> This study provided validity evidence from all 5 sources of Messick's contemporary validity framework (content, response process, internal structure, relationship with other variables, and consequences) for a simulation-based test of proficiency in intraoperative fluoroscopic control of a distal radius fracture fixated by a volar locking plate.</p>\",\"PeriodicalId\":6916,\"journal\":{\"name\":\"Acta Orthopaedica\",\"volume\":\"95 \",\"pages\":\"477-484\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-08-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11350966/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Orthopaedica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2340/17453674.2024.41345\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Orthopaedica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2340/17453674.2024.41345","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的:骨科受训人员必须能够进行术中透视成像,以评估桡骨远端骨折外侧锁定钢板手术后的手术效果。在梅西克当代有效性框架的指导下,我们的研究旨在收集使用新型沉浸式虚拟现实模拟器进行桡骨远端骨折术中成像熟练程度测试的有效性证据。在每次模拟过程中,参与者对桡骨远端骨折进行 3 次术中透视控制,包括 5 个不同的透视视图。模拟器自动记录了几项性能指标,并在两组之间进行比较: 结果:在 5 个透视视图中,有 3 个视图的模拟器指标可以区分新手和经验丰富的外科医生。根据这 3 个视图估算的综合得分显示出良好的测试-再测试可靠性,ICC = 0.82(置信区间 0.65-0.92;P < 0.001)。判别标准设定为综合得分 6.15 分,结果出现 1 次假阳性(即新手得分高于标准)和 1 次假阴性(即经验丰富的外科医生得分低于标准): 本研究从Messick当代效度框架的所有5个方面(内容、反应过程、内部结构、与其他变量的关系以及后果)为基于模拟的桡骨远端骨折术中透视控制能力测试提供了效度证据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Intraoperative fluoroscopy skills in distal radius fracture surgery: valid and reliable assessment on a novel immersive virtual reality simulator.

Background and purpose:  Orthopedic trainees must be able to perform intraoperative fluoroscopy imaging to assess the surgical result after volar locking plate surgeries of distal radius fractures. Guided by Messick's contemporary validity framework, the aim of our study was to gather evidence of validity for a test of proficiency for intraoperative imaging of a distal radius fracture using a novel immersive virtual reality simulator.

Methods:  11 novices and 9 experienced surgeons employed at orthopedic departments completed 2 individual simulator sessions. At each session the participants performed 3 repetitions of an intraoperative fluoroscopic control of a distal radius fracture, consisting of 5 different fluoroscopic views. Several performance metrics were automatically recorded by the simulator and compared between the 2 groups.

Results:  Simulator metrics for 3 of the 5 fluoroscopic views could discriminate between novices and experienced surgeons. An estimated composite score based on these 3 views showed good test-retest reliability, ICC = 0.82 (confidence interval 0.65-0.92; P < 0.001). A discriminatory standard was set at a composite score of 6.15 points resulting in 1 false positive (i.e., novice scoring better than the standard), and 1 false negative (i.e., experienced surgeon scoring worse than the standard).

Conclusion:  This study provided validity evidence from all 5 sources of Messick's contemporary validity framework (content, response process, internal structure, relationship with other variables, and consequences) for a simulation-based test of proficiency in intraoperative fluoroscopic control of a distal radius fracture fixated by a volar locking plate.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Orthopaedica
Acta Orthopaedica 医学-整形外科
CiteScore
6.40
自引率
8.10%
发文量
105
审稿时长
4-8 weeks
期刊介绍: Acta Orthopaedica (previously Acta Orthopaedica Scandinavica) presents original articles of basic research interest, as well as clinical studies in the field of orthopedics and related sub disciplines. Ever since the journal was founded in 1930, by a group of Scandinavian orthopedic surgeons, the journal has been published for an international audience. Acta Orthopaedica is owned by the Nordic Orthopaedic Federation and is the official publication of this federation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信