Jahangir Asghar, Ashvin I Patel, Joseph A Osorio, Justin S Smith, John Small, Jeffrey P Mullin, Atman Desai, Michele Temple-Wong, Rodrigo J Nicolau
{"title":"个性化椎间融合术后骨盆发生率与腰椎后凸不匹配:脊柱退行性疾病术前规划和对位的重要性。","authors":"Jahangir Asghar, Ashvin I Patel, Joseph A Osorio, Justin S Smith, John Small, Jeffrey P Mullin, Atman Desai, Michele Temple-Wong, Rodrigo J Nicolau","doi":"10.14444/8638","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Emerging data have highlighted the significance of planning and aligning total and segmental lumbar lordosis with pelvic morphology when performing short-segment fusion with the goal of reducing the risk of adjacent segment disease while also decreasing spine-related disability. This study evaluates the impact of personalized interbody implants in restoring pelvic incidence-lumbar lordosis (PI-LL) mismatch compared with a similar study using stock interbody implants.</p><p><strong>Methods: </strong>This multicenter retrospective analysis assessed radiographic pre- and postoperative spinopelvic alignment (PI-LL) in patients who underwent 1- or 2-level lumbar fusions with personalized interbody implants for degenerative (nondeformity) indications. The aim was to assess the incidence of malalignment (PI-LL ≥ 10°) both before and after fusion surgery and to determine the rate of alignment preservation and/or correction in this population.</p><p><strong>Results: </strong>There were 135 patients included in this study. Of 83 patients who were aligned preoperatively, alignment was preserved in 76 (91.6%) and worsened in 7 (8.4%). Among the 52 preoperatively malaligned patients, alignment was restored in 23 (44.2%), and 29 (55.8%) were not fully corrected. Among patients who were preoperatively aligned, there was no statistically significant difference in either the \"preserved\" or \"worsened\" groups between stock devices and personalized interbody devices. In contrast, among patients who were preoperatively malaligned, there was a statistically significant increase in the \"restored\" group (<i>P</i> = 0.046) and a statistically significant decrease in the \"worsened\" groups in patients with personalized interbodies compared with historical stock device data (<i>P</i> < 0.05).</p><p><strong>Conclusions: </strong>Compared with a historical cohort with stock implants, personalized interbody implants in short-segment fusions have shown a statistically significant improvement in restoring patients to normative PI-LL. Using 3-dimensional preoperative planning combined with personalized implants provides an important tool for planning and achieving improvement in spinopelvic parameters.</p><p><strong>Level of evidence: 3: </strong></p>","PeriodicalId":38486,"journal":{"name":"International Journal of Spine Surgery","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11483418/pdf/","citationCount":"0","resultStr":"{\"title\":\"Mismatch Between Pelvic Incidence and Lumbar Lordosis After Personalized Interbody Fusion: The Importance of Preoperative Planning and Alignment in Degenerative Spine Diseases.\",\"authors\":\"Jahangir Asghar, Ashvin I Patel, Joseph A Osorio, Justin S Smith, John Small, Jeffrey P Mullin, Atman Desai, Michele Temple-Wong, Rodrigo J Nicolau\",\"doi\":\"10.14444/8638\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Emerging data have highlighted the significance of planning and aligning total and segmental lumbar lordosis with pelvic morphology when performing short-segment fusion with the goal of reducing the risk of adjacent segment disease while also decreasing spine-related disability. This study evaluates the impact of personalized interbody implants in restoring pelvic incidence-lumbar lordosis (PI-LL) mismatch compared with a similar study using stock interbody implants.</p><p><strong>Methods: </strong>This multicenter retrospective analysis assessed radiographic pre- and postoperative spinopelvic alignment (PI-LL) in patients who underwent 1- or 2-level lumbar fusions with personalized interbody implants for degenerative (nondeformity) indications. The aim was to assess the incidence of malalignment (PI-LL ≥ 10°) both before and after fusion surgery and to determine the rate of alignment preservation and/or correction in this population.</p><p><strong>Results: </strong>There were 135 patients included in this study. Of 83 patients who were aligned preoperatively, alignment was preserved in 76 (91.6%) and worsened in 7 (8.4%). Among the 52 preoperatively malaligned patients, alignment was restored in 23 (44.2%), and 29 (55.8%) were not fully corrected. Among patients who were preoperatively aligned, there was no statistically significant difference in either the \\\"preserved\\\" or \\\"worsened\\\" groups between stock devices and personalized interbody devices. In contrast, among patients who were preoperatively malaligned, there was a statistically significant increase in the \\\"restored\\\" group (<i>P</i> = 0.046) and a statistically significant decrease in the \\\"worsened\\\" groups in patients with personalized interbodies compared with historical stock device data (<i>P</i> < 0.05).</p><p><strong>Conclusions: </strong>Compared with a historical cohort with stock implants, personalized interbody implants in short-segment fusions have shown a statistically significant improvement in restoring patients to normative PI-LL. Using 3-dimensional preoperative planning combined with personalized implants provides an important tool for planning and achieving improvement in spinopelvic parameters.</p><p><strong>Level of evidence: 3: </strong></p>\",\"PeriodicalId\":38486,\"journal\":{\"name\":\"International Journal of Spine Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11483418/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Spine Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14444/8638\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Spine Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14444/8638","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
Mismatch Between Pelvic Incidence and Lumbar Lordosis After Personalized Interbody Fusion: The Importance of Preoperative Planning and Alignment in Degenerative Spine Diseases.
Background: Emerging data have highlighted the significance of planning and aligning total and segmental lumbar lordosis with pelvic morphology when performing short-segment fusion with the goal of reducing the risk of adjacent segment disease while also decreasing spine-related disability. This study evaluates the impact of personalized interbody implants in restoring pelvic incidence-lumbar lordosis (PI-LL) mismatch compared with a similar study using stock interbody implants.
Methods: This multicenter retrospective analysis assessed radiographic pre- and postoperative spinopelvic alignment (PI-LL) in patients who underwent 1- or 2-level lumbar fusions with personalized interbody implants for degenerative (nondeformity) indications. The aim was to assess the incidence of malalignment (PI-LL ≥ 10°) both before and after fusion surgery and to determine the rate of alignment preservation and/or correction in this population.
Results: There were 135 patients included in this study. Of 83 patients who were aligned preoperatively, alignment was preserved in 76 (91.6%) and worsened in 7 (8.4%). Among the 52 preoperatively malaligned patients, alignment was restored in 23 (44.2%), and 29 (55.8%) were not fully corrected. Among patients who were preoperatively aligned, there was no statistically significant difference in either the "preserved" or "worsened" groups between stock devices and personalized interbody devices. In contrast, among patients who were preoperatively malaligned, there was a statistically significant increase in the "restored" group (P = 0.046) and a statistically significant decrease in the "worsened" groups in patients with personalized interbodies compared with historical stock device data (P < 0.05).
Conclusions: Compared with a historical cohort with stock implants, personalized interbody implants in short-segment fusions have shown a statistically significant improvement in restoring patients to normative PI-LL. Using 3-dimensional preoperative planning combined with personalized implants provides an important tool for planning and achieving improvement in spinopelvic parameters.
期刊介绍:
The International Journal of Spine Surgery is the official scientific journal of ISASS, the International Intradiscal Therapy Society, the Pittsburgh Spine Summit, and the Büttner-Janz Spinefoundation, and is an official partner of the Southern Neurosurgical Society. The goal of the International Journal of Spine Surgery is to promote and disseminate online the most up-to-date scientific and clinical research into innovations in motion preservation and new spinal surgery technology, including basic science, biologics, and tissue engineering. The Journal is dedicated to educating spine surgeons worldwide by reporting on the scientific basis, indications, surgical techniques, complications, outcomes, and follow-up data for promising spinal procedures.