C. Larivière , A.H. Eskandari , H. Mecheri , C. Duclos
{"title":"腰椎本体感觉测量的验证","authors":"C. Larivière , A.H. Eskandari , H. Mecheri , C. Duclos","doi":"10.1016/j.jelekin.2024.102924","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>To better personalize treatment and monitor recovery of individuals with low back pain, objective tests of sensorimotor functions, such as lumbar proprioception, must be selected based on their reliability and validity. The primary objective of this study was to test the concurrent validity of three measures of lumbar proprioception.</p></div><div><h3>Methods</h3><p>Thirty-one participants performed three lumbar proprioception tests (motion perception threshold, active and passive joint positioning sense), a whole-body mobility and balance (time up-and-go) and two trunk-specific postural control (threshold of stability and sensor-based sway measures) tests.</p></div><div><h3>Results</h3><p>Only the motion perception threshold proprioception test showed some validity, correlating with the trunk-specific postural control tests [r range (positive values): 0.37 to 0.60]. The three lumbar proprioception measures were not correlated to each other. The threshold of stability measure was correlated with the time up-and-go (r = 0.37) and trunk-specific (sensor-based sway measures) postural control [r range (positive values): 0.48 to 0.77] tests.</p></div><div><h3>Conclusion</h3><p>The present study generated three original findings. Only the motion perception threshold proprioception test demonstrated its concurrent validity. In fact, the three lumbar proprioception tests performed in the present study were not correlated to each other, thus assessing different constructs. Finally, the threshold of stability protocol was validated against other tests. These findings will help in selecting the most appropriate lumbar proprioception measures to study the effects of exercise treatments in patients with back pain.</p></div>","PeriodicalId":56123,"journal":{"name":"Journal of Electromyography and Kinesiology","volume":"78 ","pages":"Article 102924"},"PeriodicalIF":2.0000,"publicationDate":"2024-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of proprioception measures of the lumbar spine\",\"authors\":\"C. Larivière , A.H. Eskandari , H. Mecheri , C. Duclos\",\"doi\":\"10.1016/j.jelekin.2024.102924\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>To better personalize treatment and monitor recovery of individuals with low back pain, objective tests of sensorimotor functions, such as lumbar proprioception, must be selected based on their reliability and validity. The primary objective of this study was to test the concurrent validity of three measures of lumbar proprioception.</p></div><div><h3>Methods</h3><p>Thirty-one participants performed three lumbar proprioception tests (motion perception threshold, active and passive joint positioning sense), a whole-body mobility and balance (time up-and-go) and two trunk-specific postural control (threshold of stability and sensor-based sway measures) tests.</p></div><div><h3>Results</h3><p>Only the motion perception threshold proprioception test showed some validity, correlating with the trunk-specific postural control tests [r range (positive values): 0.37 to 0.60]. The three lumbar proprioception measures were not correlated to each other. The threshold of stability measure was correlated with the time up-and-go (r = 0.37) and trunk-specific (sensor-based sway measures) postural control [r range (positive values): 0.48 to 0.77] tests.</p></div><div><h3>Conclusion</h3><p>The present study generated three original findings. Only the motion perception threshold proprioception test demonstrated its concurrent validity. In fact, the three lumbar proprioception tests performed in the present study were not correlated to each other, thus assessing different constructs. Finally, the threshold of stability protocol was validated against other tests. These findings will help in selecting the most appropriate lumbar proprioception measures to study the effects of exercise treatments in patients with back pain.</p></div>\",\"PeriodicalId\":56123,\"journal\":{\"name\":\"Journal of Electromyography and Kinesiology\",\"volume\":\"78 \",\"pages\":\"Article 102924\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-08-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electromyography and Kinesiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1050641124000683\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electromyography and Kinesiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1050641124000683","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
Validation of proprioception measures of the lumbar spine
Background
To better personalize treatment and monitor recovery of individuals with low back pain, objective tests of sensorimotor functions, such as lumbar proprioception, must be selected based on their reliability and validity. The primary objective of this study was to test the concurrent validity of three measures of lumbar proprioception.
Methods
Thirty-one participants performed three lumbar proprioception tests (motion perception threshold, active and passive joint positioning sense), a whole-body mobility and balance (time up-and-go) and two trunk-specific postural control (threshold of stability and sensor-based sway measures) tests.
Results
Only the motion perception threshold proprioception test showed some validity, correlating with the trunk-specific postural control tests [r range (positive values): 0.37 to 0.60]. The three lumbar proprioception measures were not correlated to each other. The threshold of stability measure was correlated with the time up-and-go (r = 0.37) and trunk-specific (sensor-based sway measures) postural control [r range (positive values): 0.48 to 0.77] tests.
Conclusion
The present study generated three original findings. Only the motion perception threshold proprioception test demonstrated its concurrent validity. In fact, the three lumbar proprioception tests performed in the present study were not correlated to each other, thus assessing different constructs. Finally, the threshold of stability protocol was validated against other tests. These findings will help in selecting the most appropriate lumbar proprioception measures to study the effects of exercise treatments in patients with back pain.
期刊介绍:
Journal of Electromyography & Kinesiology is the primary source for outstanding original articles on the study of human movement from muscle contraction via its motor units and sensory system to integrated motion through mechanical and electrical detection techniques.
As the official publication of the International Society of Electrophysiology and Kinesiology, the journal is dedicated to publishing the best work in all areas of electromyography and kinesiology, including: control of movement, muscle fatigue, muscle and nerve properties, joint biomechanics and electrical stimulation. Applications in rehabilitation, sports & exercise, motion analysis, ergonomics, alternative & complimentary medicine, measures of human performance and technical articles on electromyographic signal processing are welcome.