腰椎本体感觉测量的验证

IF 2 4区 医学 Q3 NEUROSCIENCES
{"title":"腰椎本体感觉测量的验证","authors":"","doi":"10.1016/j.jelekin.2024.102924","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>To better personalize treatment and monitor recovery of individuals with low back pain, objective tests of sensorimotor functions, such as lumbar proprioception, must be selected based on their reliability and validity. The primary objective of this study was to test the concurrent validity of three measures of lumbar proprioception.</p></div><div><h3>Methods</h3><p>Thirty-one participants performed three lumbar proprioception tests (motion perception threshold, active and passive joint positioning sense), a whole-body mobility and balance (time up-and-go) and two trunk-specific postural control (threshold of stability and sensor-based sway measures) tests.</p></div><div><h3>Results</h3><p>Only the motion perception threshold proprioception test showed some validity, correlating with the trunk-specific postural control tests [r range (positive values): 0.37 to 0.60]. The three lumbar proprioception measures were not correlated to each other. The threshold of stability measure was correlated with the time up-and-go (r = 0.37) and trunk-specific (sensor-based sway measures) postural control [r range (positive values): 0.48 to 0.77] tests.</p></div><div><h3>Conclusion</h3><p>The present study generated three original findings. Only the motion perception threshold proprioception test demonstrated its concurrent validity. In fact, the three lumbar proprioception tests performed in the present study were not correlated to each other, thus assessing different constructs. Finally, the threshold of stability protocol was validated against other tests. These findings will help in selecting the most appropriate lumbar proprioception measures to study the effects of exercise treatments in patients with back pain.</p></div>","PeriodicalId":56123,"journal":{"name":"Journal of Electromyography and Kinesiology","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of proprioception measures of the lumbar spine\",\"authors\":\"\",\"doi\":\"10.1016/j.jelekin.2024.102924\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>To better personalize treatment and monitor recovery of individuals with low back pain, objective tests of sensorimotor functions, such as lumbar proprioception, must be selected based on their reliability and validity. The primary objective of this study was to test the concurrent validity of three measures of lumbar proprioception.</p></div><div><h3>Methods</h3><p>Thirty-one participants performed three lumbar proprioception tests (motion perception threshold, active and passive joint positioning sense), a whole-body mobility and balance (time up-and-go) and two trunk-specific postural control (threshold of stability and sensor-based sway measures) tests.</p></div><div><h3>Results</h3><p>Only the motion perception threshold proprioception test showed some validity, correlating with the trunk-specific postural control tests [r range (positive values): 0.37 to 0.60]. The three lumbar proprioception measures were not correlated to each other. The threshold of stability measure was correlated with the time up-and-go (r = 0.37) and trunk-specific (sensor-based sway measures) postural control [r range (positive values): 0.48 to 0.77] tests.</p></div><div><h3>Conclusion</h3><p>The present study generated three original findings. Only the motion perception threshold proprioception test demonstrated its concurrent validity. In fact, the three lumbar proprioception tests performed in the present study were not correlated to each other, thus assessing different constructs. Finally, the threshold of stability protocol was validated against other tests. These findings will help in selecting the most appropriate lumbar proprioception measures to study the effects of exercise treatments in patients with back pain.</p></div>\",\"PeriodicalId\":56123,\"journal\":{\"name\":\"Journal of Electromyography and Kinesiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-08-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electromyography and Kinesiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1050641124000683\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electromyography and Kinesiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1050641124000683","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

背景为了更好地对腰痛患者进行个性化治疗并监测其康复情况,必须根据腰部本体感觉等感觉运动功能的可靠性和有效性来选择客观测试。本研究的主要目的是测试腰部本体感觉的三种测量方法的并发有效性。方法31名参与者进行了三种腰部本体感觉测试(运动感知阈值、主动和被动关节定位感)、一种全身移动性和平衡性测试(向上走动时间)以及两种躯干特定姿势控制测试(稳定性阈值和基于传感器的摇摆测量)。结果只有运动感知阈值本体感觉测试显示出一定的有效性,与躯干特定姿势控制测试相关[r 范围(正值):0.37 至 0.60]。三种腰部本体感觉测量结果互不相关。稳定性阈值测量与时间上行-下行(r = 0.37)和躯干特定(基于传感器的摇摆测量)姿势控制测试[r 范围(正值):0.48 至 0.77]相关。只有运动感知阈值本体感觉测试证明了其并发有效性。事实上,本研究中进行的三种腰部本体感觉测试互不相关,因此评估的是不同的结构。最后,稳定性阈值方案与其他测试进行了验证。这些发现将有助于选择最合适的腰部本体感觉测量方法,以研究腰痛患者的运动治疗效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Validation of proprioception measures of the lumbar spine

Background

To better personalize treatment and monitor recovery of individuals with low back pain, objective tests of sensorimotor functions, such as lumbar proprioception, must be selected based on their reliability and validity. The primary objective of this study was to test the concurrent validity of three measures of lumbar proprioception.

Methods

Thirty-one participants performed three lumbar proprioception tests (motion perception threshold, active and passive joint positioning sense), a whole-body mobility and balance (time up-and-go) and two trunk-specific postural control (threshold of stability and sensor-based sway measures) tests.

Results

Only the motion perception threshold proprioception test showed some validity, correlating with the trunk-specific postural control tests [r range (positive values): 0.37 to 0.60]. The three lumbar proprioception measures were not correlated to each other. The threshold of stability measure was correlated with the time up-and-go (r = 0.37) and trunk-specific (sensor-based sway measures) postural control [r range (positive values): 0.48 to 0.77] tests.

Conclusion

The present study generated three original findings. Only the motion perception threshold proprioception test demonstrated its concurrent validity. In fact, the three lumbar proprioception tests performed in the present study were not correlated to each other, thus assessing different constructs. Finally, the threshold of stability protocol was validated against other tests. These findings will help in selecting the most appropriate lumbar proprioception measures to study the effects of exercise treatments in patients with back pain.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.70
自引率
8.00%
发文量
70
审稿时长
74 days
期刊介绍: Journal of Electromyography & Kinesiology is the primary source for outstanding original articles on the study of human movement from muscle contraction via its motor units and sensory system to integrated motion through mechanical and electrical detection techniques. As the official publication of the International Society of Electrophysiology and Kinesiology, the journal is dedicated to publishing the best work in all areas of electromyography and kinesiology, including: control of movement, muscle fatigue, muscle and nerve properties, joint biomechanics and electrical stimulation. Applications in rehabilitation, sports & exercise, motion analysis, ergonomics, alternative & complimentary medicine, measures of human performance and technical articles on electromyographic signal processing are welcome.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信