{"title":"大口径胸管插入:使用两根导丝的 Seldinger 技术。","authors":"Atsushi Saiga, Takeshi Aramaki, Rui Sato","doi":"10.22575/interventionalradiology.2023-0030","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Large-bore chest tube insertion is commonly performed using the trocar technique and blunt dissection; however, large-bore chest tube can cause severe visceral injury due to penetration, which is a life-threatening complication. Conversely, small-bore chest tubes can be safely inserted using the Seldinger technique; however, small-bore chest tubes are prone to blockage, especially in empyema cases. Therefore, this study aimed to demonstrate large-bore chest tube insertion using the Seldinger technique over two guidewires following image-guided puncture.</p><p><strong>Material and methods: </strong>We started performing large-bore chest tube insertion using the Seldinger technique over two guidewires following image-guided puncture in February 2022. Demographic data and procedural details, such as chest tube size, dilator size, procedure time, and type of image-guided puncture, of patients who underwent this procedure between February 2022 and March 2023 were retrospectively reviewed. Technical success was defined as the successful drainage of the pleural cavity.</p><p><strong>Results: </strong>This method was used for performing ten procedures in nine patients who presented with empyema, pneumothorax, and pulmonary fistula. The insertion of a large-bore chest tube with a size ranging from 18- to 24-French was successfully performed in all cases without any complications. The median procedure time was 17.5 (first quartile-third quartile, 13.5-28.0) min.</p><p><strong>Conclusions: </strong>Large-bore chest tube insertion using the Seldinger technique over two guidewires may be used as an alternative to conventional methods.</p>","PeriodicalId":73503,"journal":{"name":"Interventional radiology (Higashimatsuyama-shi (Japan)","volume":"9 2","pages":"74-77"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11336239/pdf/","citationCount":"0","resultStr":"{\"title\":\"Large-bore Chest Tube Insertion: Seldinger Technique over Two Guidewires.\",\"authors\":\"Atsushi Saiga, Takeshi Aramaki, Rui Sato\",\"doi\":\"10.22575/interventionalradiology.2023-0030\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Large-bore chest tube insertion is commonly performed using the trocar technique and blunt dissection; however, large-bore chest tube can cause severe visceral injury due to penetration, which is a life-threatening complication. Conversely, small-bore chest tubes can be safely inserted using the Seldinger technique; however, small-bore chest tubes are prone to blockage, especially in empyema cases. Therefore, this study aimed to demonstrate large-bore chest tube insertion using the Seldinger technique over two guidewires following image-guided puncture.</p><p><strong>Material and methods: </strong>We started performing large-bore chest tube insertion using the Seldinger technique over two guidewires following image-guided puncture in February 2022. Demographic data and procedural details, such as chest tube size, dilator size, procedure time, and type of image-guided puncture, of patients who underwent this procedure between February 2022 and March 2023 were retrospectively reviewed. Technical success was defined as the successful drainage of the pleural cavity.</p><p><strong>Results: </strong>This method was used for performing ten procedures in nine patients who presented with empyema, pneumothorax, and pulmonary fistula. The insertion of a large-bore chest tube with a size ranging from 18- to 24-French was successfully performed in all cases without any complications. The median procedure time was 17.5 (first quartile-third quartile, 13.5-28.0) min.</p><p><strong>Conclusions: </strong>Large-bore chest tube insertion using the Seldinger technique over two guidewires may be used as an alternative to conventional methods.</p>\",\"PeriodicalId\":73503,\"journal\":{\"name\":\"Interventional radiology (Higashimatsuyama-shi (Japan)\",\"volume\":\"9 2\",\"pages\":\"74-77\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11336239/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional radiology (Higashimatsuyama-shi (Japan)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22575/interventionalradiology.2023-0030\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional radiology (Higashimatsuyama-shi (Japan)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22575/interventionalradiology.2023-0030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
Large-bore Chest Tube Insertion: Seldinger Technique over Two Guidewires.
Purpose: Large-bore chest tube insertion is commonly performed using the trocar technique and blunt dissection; however, large-bore chest tube can cause severe visceral injury due to penetration, which is a life-threatening complication. Conversely, small-bore chest tubes can be safely inserted using the Seldinger technique; however, small-bore chest tubes are prone to blockage, especially in empyema cases. Therefore, this study aimed to demonstrate large-bore chest tube insertion using the Seldinger technique over two guidewires following image-guided puncture.
Material and methods: We started performing large-bore chest tube insertion using the Seldinger technique over two guidewires following image-guided puncture in February 2022. Demographic data and procedural details, such as chest tube size, dilator size, procedure time, and type of image-guided puncture, of patients who underwent this procedure between February 2022 and March 2023 were retrospectively reviewed. Technical success was defined as the successful drainage of the pleural cavity.
Results: This method was used for performing ten procedures in nine patients who presented with empyema, pneumothorax, and pulmonary fistula. The insertion of a large-bore chest tube with a size ranging from 18- to 24-French was successfully performed in all cases without any complications. The median procedure time was 17.5 (first quartile-third quartile, 13.5-28.0) min.
Conclusions: Large-bore chest tube insertion using the Seldinger technique over two guidewires may be used as an alternative to conventional methods.