{"title":"将灰度结果与超微血管成像和剪切波弹性成像相结合在非质量乳腺病变的标准化和管理中的作用。","authors":"Seda Aladag Kurt, Fusun Taskin, Yasemin Kayadibi, Tulin Ozturk, İbrahim Adaletli, Gul Esen Icten","doi":"10.1097/RUQ.0000000000000689","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>The non-mass breast lesions on ultrasound (US) are a group of challenging pathology. We aimed to standardize these grayscale findings and investigate the effectiveness of superb microvascular imaging (SMI) and shear wave elastography (SWE). A total of 195 lesions were evaluated by B-mode US, SWE, and SMI in the same session. A \"NON-MASS model\" was built on grayscale US to group the lesions only as areas and those with associated features: microcalcifications, architectural distortion, ductal changes, and microcysts. The mean stiffness parameters Emean, Eratio, and mean vascular index (VI) were recorded following consecutive measurements. Besides, the microvascularity was graded based on Adler's classification (grades 0 to 3). Lesions were divided into 3 groups: benign, category B3, and malignant. One hundred twelve (57.4%) lesions were benign, 23 (11.8%) were B3, and 60 were (30.8%) in the malignant category. Thirty-eight (19.5%) lesions were observed only as an area, whereas associated features were present in 157 lesions (80.5%). Distortion was the only associated feature predicting malignancy among the grayscale findings (P < 0.001). There was a significant difference between malignant and nonmalignant (benign and B3) groups in terms of Adler's grade, Emean, Eratio, and VI values (P < 0.001). Sensitivity, specificity, and accuracy increased when advanced imaging parameters were added to grayscale findings (P < 0.001). In the presence of microcalcifications, architectural distortion, high elasticity, and hypervascularity in the \"NON-MASS\" imaging model, the suspicion of malignancy increases. The non-mass findings and advanced imaging techniques have the potential to find greater coverage in the following versions of BI-RADS atlas.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Role of Combining Grayscale Findings With Superb Microvascular Imaging and Shear Wave Elastography in Standardization and Management of NON-MASS Breast Lesions.\",\"authors\":\"Seda Aladag Kurt, Fusun Taskin, Yasemin Kayadibi, Tulin Ozturk, İbrahim Adaletli, Gul Esen Icten\",\"doi\":\"10.1097/RUQ.0000000000000689\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Abstract: </strong>The non-mass breast lesions on ultrasound (US) are a group of challenging pathology. We aimed to standardize these grayscale findings and investigate the effectiveness of superb microvascular imaging (SMI) and shear wave elastography (SWE). A total of 195 lesions were evaluated by B-mode US, SWE, and SMI in the same session. A \\\"NON-MASS model\\\" was built on grayscale US to group the lesions only as areas and those with associated features: microcalcifications, architectural distortion, ductal changes, and microcysts. The mean stiffness parameters Emean, Eratio, and mean vascular index (VI) were recorded following consecutive measurements. Besides, the microvascularity was graded based on Adler's classification (grades 0 to 3). Lesions were divided into 3 groups: benign, category B3, and malignant. One hundred twelve (57.4%) lesions were benign, 23 (11.8%) were B3, and 60 were (30.8%) in the malignant category. Thirty-eight (19.5%) lesions were observed only as an area, whereas associated features were present in 157 lesions (80.5%). Distortion was the only associated feature predicting malignancy among the grayscale findings (P < 0.001). There was a significant difference between malignant and nonmalignant (benign and B3) groups in terms of Adler's grade, Emean, Eratio, and VI values (P < 0.001). Sensitivity, specificity, and accuracy increased when advanced imaging parameters were added to grayscale findings (P < 0.001). In the presence of microcalcifications, architectural distortion, high elasticity, and hypervascularity in the \\\"NON-MASS\\\" imaging model, the suspicion of malignancy increases. The non-mass findings and advanced imaging techniques have the potential to find greater coverage in the following versions of BI-RADS atlas.</p>\",\"PeriodicalId\":49116,\"journal\":{\"name\":\"Ultrasound Quarterly\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasound Quarterly\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/RUQ.0000000000000689\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Quarterly","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RUQ.0000000000000689","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

摘要:超声(US)显示的非肿块性乳腺病变是一组具有挑战性的病理。我们的目的是将这些灰度检查结果标准化,并研究超微血管成像(SMI)和剪切波弹性成像(SWE)的有效性。我们在同一疗程中通过 B 型 US、SWE 和 SMI 对 195 个病灶进行了评估。在灰阶 US 上建立了一个 "NON-MASS 模型",仅将病变分为区域和具有相关特征的病变:微钙化、结构变形、导管变化和微囊。连续测量后记录平均硬度参数 Emean、Eratio 和平均血管指数(VI)。此外,还根据阿德勒分类法(0 至 3 级)对微血管进行了分级。病变分为三组:良性、B3 类和恶性。112个(57.4%)病灶为良性,23个(11.8%)为B3类,60个(30.8%)为恶性。有 38 个(19.5%)病灶仅观察到一个区域,而有 157 个病灶(80.5%)存在相关特征。在灰度结果中,变形是预测恶性的唯一相关特征(P < 0.001)。恶性组和非恶性组(良性和 B3)在 Adler 分级、Emean、Eratio 和 VI 值方面存在明显差异(P < 0.001)。在灰度结果中加入高级成像参数后,灵敏度、特异性和准确性均有所提高(P < 0.001)。在 "非肿块 "成像模型中,如果存在微钙化、结构变形、高弹性和高血管性,则对恶性肿瘤的怀疑会增加。非肿块检查结果和先进的成像技术有可能在后续版本的 BI-RADS 图谱中得到更广泛的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Role of Combining Grayscale Findings With Superb Microvascular Imaging and Shear Wave Elastography in Standardization and Management of NON-MASS Breast Lesions.

Abstract: The non-mass breast lesions on ultrasound (US) are a group of challenging pathology. We aimed to standardize these grayscale findings and investigate the effectiveness of superb microvascular imaging (SMI) and shear wave elastography (SWE). A total of 195 lesions were evaluated by B-mode US, SWE, and SMI in the same session. A "NON-MASS model" was built on grayscale US to group the lesions only as areas and those with associated features: microcalcifications, architectural distortion, ductal changes, and microcysts. The mean stiffness parameters Emean, Eratio, and mean vascular index (VI) were recorded following consecutive measurements. Besides, the microvascularity was graded based on Adler's classification (grades 0 to 3). Lesions were divided into 3 groups: benign, category B3, and malignant. One hundred twelve (57.4%) lesions were benign, 23 (11.8%) were B3, and 60 were (30.8%) in the malignant category. Thirty-eight (19.5%) lesions were observed only as an area, whereas associated features were present in 157 lesions (80.5%). Distortion was the only associated feature predicting malignancy among the grayscale findings (P < 0.001). There was a significant difference between malignant and nonmalignant (benign and B3) groups in terms of Adler's grade, Emean, Eratio, and VI values (P < 0.001). Sensitivity, specificity, and accuracy increased when advanced imaging parameters were added to grayscale findings (P < 0.001). In the presence of microcalcifications, architectural distortion, high elasticity, and hypervascularity in the "NON-MASS" imaging model, the suspicion of malignancy increases. The non-mass findings and advanced imaging techniques have the potential to find greater coverage in the following versions of BI-RADS atlas.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ultrasound Quarterly
Ultrasound Quarterly RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.50
自引率
7.70%
发文量
105
审稿时长
>12 weeks
期刊介绍: Ultrasound Quarterly provides coverage of the newest, most sophisticated ultrasound techniques as well as in-depth analysis of important developments in this dynamic field. The journal publishes reviews of a wide variety of topics including trans-vaginal ultrasonography, detection of fetal anomalies, color Doppler flow imaging, pediatric ultrasonography, and breast sonography. Official Journal of the Society of Radiologists in Ultrasound
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信