{"title":"肝脏恶性肿瘤质子治疗前使用超细25号针头在CT引导下植入弧形标记物","authors":"Akihiro Horibe, Kengo Ohta, Jumpei Shoji, Mototaka Hatano, Yujiro Shiotani, Kumiko Anan, Kento Nomura, Hiromitsu Iwata, Hiroyuki Ogino","doi":"10.1007/s00270-024-03808-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Proton therapy is highly effective for liver malignancies, and to increase its accuracy, placement of fiducial markers in the liver is preferred. We retrospectively evaluated the safety and feasibility of CT-guided fiducial marker implantation using ultra-fine 25-gauge needles before proton therapy for liver malignancies.</p><p><strong>Materials and methods: </strong>Between May 2016 and April 2021, 334 cases were investigated. All of procedures were performed without anesthesia. Technical success was defined as the completion of implantation at the intended site. Tumor-marker distance and possibility of synchronization between tumors and markers were evaluated and compared with Mann-Whitney U test. Complications were evaluated using the Common Terminology Criteria for Adverse Events, version 4.0.</p><p><strong>Results: </strong>Technical success rate was 97.3%. Tumor-marker distance was 19.1 mm (median, range 0-96) in the group in which the implanted marker was synchronized with tumor (n = 315), while it was 34.5 mm (median, range 6-94) in the group in which the implanted marker was not synchronized (n = 13) (p value = 0.011 < 0.05). The complication rate was 2.4%, 2 were classified as grade 4 and 5 as grade 1, and 1 as grade 2. There were no grade 3 or higher complications that seemed to be related to the procedure.</p><p><strong>Conclusion: </strong>CT-guided marker implantation using a 25-gauge needle achieved a satisfactory success rate with few complications and was useful for the image-guided and respiratory-synchronized proton therapy. LEVEL OF EVIDENCE 3: Local non-random sample.</p>","PeriodicalId":9591,"journal":{"name":"CardioVascular and Interventional Radiology","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"CT-Guided Fiducial Marker Implantation with Ultra-fine 25-Gauge Needle Prior to Proton Therapy for Liver Malignancies.\",\"authors\":\"Akihiro Horibe, Kengo Ohta, Jumpei Shoji, Mototaka Hatano, Yujiro Shiotani, Kumiko Anan, Kento Nomura, Hiromitsu Iwata, Hiroyuki Ogino\",\"doi\":\"10.1007/s00270-024-03808-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Proton therapy is highly effective for liver malignancies, and to increase its accuracy, placement of fiducial markers in the liver is preferred. We retrospectively evaluated the safety and feasibility of CT-guided fiducial marker implantation using ultra-fine 25-gauge needles before proton therapy for liver malignancies.</p><p><strong>Materials and methods: </strong>Between May 2016 and April 2021, 334 cases were investigated. All of procedures were performed without anesthesia. Technical success was defined as the completion of implantation at the intended site. Tumor-marker distance and possibility of synchronization between tumors and markers were evaluated and compared with Mann-Whitney U test. Complications were evaluated using the Common Terminology Criteria for Adverse Events, version 4.0.</p><p><strong>Results: </strong>Technical success rate was 97.3%. Tumor-marker distance was 19.1 mm (median, range 0-96) in the group in which the implanted marker was synchronized with tumor (n = 315), while it was 34.5 mm (median, range 6-94) in the group in which the implanted marker was not synchronized (n = 13) (p value = 0.011 < 0.05). The complication rate was 2.4%, 2 were classified as grade 4 and 5 as grade 1, and 1 as grade 2. There were no grade 3 or higher complications that seemed to be related to the procedure.</p><p><strong>Conclusion: </strong>CT-guided marker implantation using a 25-gauge needle achieved a satisfactory success rate with few complications and was useful for the image-guided and respiratory-synchronized proton therapy. LEVEL OF EVIDENCE 3: Local non-random sample.</p>\",\"PeriodicalId\":9591,\"journal\":{\"name\":\"CardioVascular and Interventional Radiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CardioVascular and Interventional Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00270-024-03808-8\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CardioVascular and Interventional Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00270-024-03808-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/22 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
CT-Guided Fiducial Marker Implantation with Ultra-fine 25-Gauge Needle Prior to Proton Therapy for Liver Malignancies.
Purpose: Proton therapy is highly effective for liver malignancies, and to increase its accuracy, placement of fiducial markers in the liver is preferred. We retrospectively evaluated the safety and feasibility of CT-guided fiducial marker implantation using ultra-fine 25-gauge needles before proton therapy for liver malignancies.
Materials and methods: Between May 2016 and April 2021, 334 cases were investigated. All of procedures were performed without anesthesia. Technical success was defined as the completion of implantation at the intended site. Tumor-marker distance and possibility of synchronization between tumors and markers were evaluated and compared with Mann-Whitney U test. Complications were evaluated using the Common Terminology Criteria for Adverse Events, version 4.0.
Results: Technical success rate was 97.3%. Tumor-marker distance was 19.1 mm (median, range 0-96) in the group in which the implanted marker was synchronized with tumor (n = 315), while it was 34.5 mm (median, range 6-94) in the group in which the implanted marker was not synchronized (n = 13) (p value = 0.011 < 0.05). The complication rate was 2.4%, 2 were classified as grade 4 and 5 as grade 1, and 1 as grade 2. There were no grade 3 or higher complications that seemed to be related to the procedure.
Conclusion: CT-guided marker implantation using a 25-gauge needle achieved a satisfactory success rate with few complications and was useful for the image-guided and respiratory-synchronized proton therapy. LEVEL OF EVIDENCE 3: Local non-random sample.
期刊介绍:
CardioVascular and Interventional Radiology (CVIR) is the official journal of the Cardiovascular and Interventional Radiological Society of Europe, and is also the official organ of a number of additional distinguished national and international interventional radiological societies. CVIR publishes double blinded peer-reviewed original research work including clinical and laboratory investigations, technical notes, case reports, works in progress, and letters to the editor, as well as review articles, pictorial essays, editorials, and special invited submissions in the field of vascular and interventional radiology. Beside the communication of the latest research results in this field, it is also the aim of CVIR to support continuous medical education. Articles that are accepted for publication are done so with the understanding that they, or their substantive contents, have not been and will not be submitted to any other publication.