长期使用植入式循环记录器记录马的心电图。

IF 0.7 4区 农林科学 Q3 VETERINARY SCIENCES
Acta veterinaria Hungarica Pub Date : 2024-08-22 Print Date: 2024-09-12 DOI:10.1556/004.2024.01075
Szilvia Kovács, Gábor Bodó, Ferenc Zs Tóth, László Néder, Zoltán Bakos
{"title":"长期使用植入式循环记录器记录马的心电图。","authors":"Szilvia Kovács, Gábor Bodó, Ferenc Zs Tóth, László Néder, Zoltán Bakos","doi":"10.1556/004.2024.01075","DOIUrl":null,"url":null,"abstract":"<p><p>Potential arrhythmias recorded by cardiac monitors using the built-in human algorithm are as follows: total number of episodes, ventricular tachycardia, asystole, bradycardia, atrial tachycardia, atrial fibrillation and the percentage of time spent in atrial tachycardia or atrial fibrillation. Long-term use of an insertable cardiac monitor (loop recorder) has been reported in one horse earlier, but its accurate role as a diagnostic tool is still unclear. The aim of the present study was to investigate the long-term applicability of the Reveal XT cardiac monitor for recording cardiac arrhythmias in adult horses. The Reveal XT cardiac monitor was implanted in 12 horses under sedation in standing position. Median duration of data recording calculated for the population was 1,169 days. The number of false positive detections of asystole and bradycardia was extremely high in all horses. For atrial fibrillation, false positive detection occurred in five and false negative detection occurred in one horse. The present study showed that the long-term use of the Reveal XT cardiac monitor is feasible, well-tolerated and the devices work reliably, without complications. The human algorithm could not be used for automatic detection of arrhythmic episodes in the study population. The device could detect atrial fibrillation in horses, but the recorded AF burden was inaccurate and the stored ECGs had to be manually interpreted. Because the human analyser algorithm of this cardiac monitor fails to identify bradyarrhythmias in horses based on our results, this instrument is not capable for accurately determining the aetiology of episodic collapse in this species.</p>","PeriodicalId":7247,"journal":{"name":"Acta veterinaria Hungarica","volume":" ","pages":"178-185"},"PeriodicalIF":0.7000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Long-term use of an implantable loop recorder for ECG recording in horses.\",\"authors\":\"Szilvia Kovács, Gábor Bodó, Ferenc Zs Tóth, László Néder, Zoltán Bakos\",\"doi\":\"10.1556/004.2024.01075\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Potential arrhythmias recorded by cardiac monitors using the built-in human algorithm are as follows: total number of episodes, ventricular tachycardia, asystole, bradycardia, atrial tachycardia, atrial fibrillation and the percentage of time spent in atrial tachycardia or atrial fibrillation. Long-term use of an insertable cardiac monitor (loop recorder) has been reported in one horse earlier, but its accurate role as a diagnostic tool is still unclear. The aim of the present study was to investigate the long-term applicability of the Reveal XT cardiac monitor for recording cardiac arrhythmias in adult horses. The Reveal XT cardiac monitor was implanted in 12 horses under sedation in standing position. Median duration of data recording calculated for the population was 1,169 days. The number of false positive detections of asystole and bradycardia was extremely high in all horses. For atrial fibrillation, false positive detection occurred in five and false negative detection occurred in one horse. The present study showed that the long-term use of the Reveal XT cardiac monitor is feasible, well-tolerated and the devices work reliably, without complications. The human algorithm could not be used for automatic detection of arrhythmic episodes in the study population. The device could detect atrial fibrillation in horses, but the recorded AF burden was inaccurate and the stored ECGs had to be manually interpreted. Because the human analyser algorithm of this cardiac monitor fails to identify bradyarrhythmias in horses based on our results, this instrument is not capable for accurately determining the aetiology of episodic collapse in this species.</p>\",\"PeriodicalId\":7247,\"journal\":{\"name\":\"Acta veterinaria Hungarica\",\"volume\":\" \",\"pages\":\"178-185\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta veterinaria Hungarica\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1556/004.2024.01075\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/12 0:00:00\",\"PubModel\":\"Print\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta veterinaria Hungarica","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1556/004.2024.01075","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/12 0:00:00","PubModel":"Print","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

心电监护仪利用内置人工算法记录的潜在心律失常如下:发作总数、室性心动过速、心搏过速、心动过缓、房性心动过速、心房颤动以及房性心动过速或心房颤动的时间百分比。早先有一匹马报告了长期使用插入式心脏监测仪(循环记录仪)的情况,但其作为诊断工具的准确作用仍不明确。本研究旨在调查 Reveal XT 心电监护仪记录成年马心律失常的长期适用性。Reveal XT 心电监护仪被植入 12 匹马的体内,马匹在镇静状态下保持站立姿势。数据记录的中位持续时间为 1,169 天。所有马匹的心搏骤停和心动过缓的假阳性检测次数都非常高。在心房颤动方面,5 匹马出现了假阳性检测,1 匹马出现了假阴性检测。本研究表明,长期使用 Reveal XT 心电监护仪是可行的,耐受性良好,设备工作可靠,无并发症。在研究人群中,人类算法无法用于心律失常发作的自动检测。该设备可以检测到马匹的心房颤动,但记录的心房颤动负荷并不准确,存储的心电图必须手动解读。根据我们的研究结果,该心电监护仪的人工分析算法无法识别马匹的缓性心律失常,因此该仪器无法准确判断该物种发作性昏厥的病因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Long-term use of an implantable loop recorder for ECG recording in horses.

Potential arrhythmias recorded by cardiac monitors using the built-in human algorithm are as follows: total number of episodes, ventricular tachycardia, asystole, bradycardia, atrial tachycardia, atrial fibrillation and the percentage of time spent in atrial tachycardia or atrial fibrillation. Long-term use of an insertable cardiac monitor (loop recorder) has been reported in one horse earlier, but its accurate role as a diagnostic tool is still unclear. The aim of the present study was to investigate the long-term applicability of the Reveal XT cardiac monitor for recording cardiac arrhythmias in adult horses. The Reveal XT cardiac monitor was implanted in 12 horses under sedation in standing position. Median duration of data recording calculated for the population was 1,169 days. The number of false positive detections of asystole and bradycardia was extremely high in all horses. For atrial fibrillation, false positive detection occurred in five and false negative detection occurred in one horse. The present study showed that the long-term use of the Reveal XT cardiac monitor is feasible, well-tolerated and the devices work reliably, without complications. The human algorithm could not be used for automatic detection of arrhythmic episodes in the study population. The device could detect atrial fibrillation in horses, but the recorded AF burden was inaccurate and the stored ECGs had to be manually interpreted. Because the human analyser algorithm of this cardiac monitor fails to identify bradyarrhythmias in horses based on our results, this instrument is not capable for accurately determining the aetiology of episodic collapse in this species.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta veterinaria Hungarica
Acta veterinaria Hungarica 农林科学-兽医学
CiteScore
1.80
自引率
0.00%
发文量
39
审稿时长
>36 weeks
期刊介绍: Acta Veterinaria Hungarica publishes original research papers presenting new scientific results of international interest, and to a limited extent also review articles and clinical case reports, on veterinary physiology (physiological chemistry and metabolism), veterinary microbiology (bacteriology, virology, immunology, molecular biology), on the infectious diseases of domestic animals, on veterinary parasitology, pathology, clinical veterinary science and reproduction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信