Nicholas J Yee, Carlo Iorio, Nicholas Shkumat, Brett Rocos, David Lebel, Mark Camp
{"title":"小儿神经肌肉性脊柱侧凸患者无需镇静的 \"超低剂量 \"CT。","authors":"Nicholas J Yee, Carlo Iorio, Nicholas Shkumat, Brett Rocos, David Lebel, Mark Camp","doi":"10.1097/BPO.0000000000002786","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Children with neuromuscular scoliosis undergoing scoliosis surgery face substantial rates of complications. To mitigate surgical risks such as blood loss in pediatric patients with neuromuscular scoliosis, this study focuses on enabling instrumentation planning for their abnormal vertebral and pelvic anatomy and osteopenia. This study assessed the feasibility of an \"ultralow-dose\" CT (ULD CT) protocol without sedation in pediatric patients with neuromuscular scoliosis who often have comorbid movement disorders. Our prospective quality improvement study aims: (1) to determine if ULD CT without sedation is feasible in this patient group; (2) to quantify the radiation dose from ULD CT and compare it with preoperative spine radiographs (XR); and (3) to assess if ULD CT allows accurate anatomical assessment and intraoperative navigation given the prevalence of movement disorders.</p><p><strong>Methods: </strong>Children with neuromuscular scoliosis underwent spine XR and ULD CT scans. Chart reviews assessed disease etiology and comorbidities. Radiation dose was quantified through Monte-Carlo simulations giving dose indices and effective dose, with statistical analysis done using a paired student's t-test (α=0.05). CT image quality was assessed for its use in preoperative planning and intraoperative navigation.</p><p><strong>Results: </strong>Fourteen patients (5 males, 9 females, average age 14±3 y) participated. One patient needed sedation due to autism spectrum disorder and global developmental delay. The radiation dose for spine XR was 0.5±0.2 mSv, and ULD CT was 0.6±0.1 mSv. There was no statistically significant difference in radiation doses between methods. All ULD CT scans had adequate quality for preoperative assessment of pedicle diameter and orientation, obstacles impeding pedicle entry, S2 Alar-Iliac screw orientation, and intraoperative navigation.</p><p><strong>Conclusions: </strong>ULD CT without sedation is feasible for children with neuromuscular scoliosis. Radiation doses were comparable to standard radiographs. ULD CT provided accurate anatomical assessments and supported intraoperative navigation, proving beneficial despite movement disorders in these patients.</p><p><strong>Level of evidence: </strong>Level 2-Development of diagnostic criteria on basis of consecutive patients (with universally applied reference widely accepted standard).</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"\\\"Ultralow-dose\\\" CT Without Sedation in Pediatric Patients With Neuromuscular Scoliosis.\",\"authors\":\"Nicholas J Yee, Carlo Iorio, Nicholas Shkumat, Brett Rocos, David Lebel, Mark Camp\",\"doi\":\"10.1097/BPO.0000000000002786\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Children with neuromuscular scoliosis undergoing scoliosis surgery face substantial rates of complications. To mitigate surgical risks such as blood loss in pediatric patients with neuromuscular scoliosis, this study focuses on enabling instrumentation planning for their abnormal vertebral and pelvic anatomy and osteopenia. This study assessed the feasibility of an \\\"ultralow-dose\\\" CT (ULD CT) protocol without sedation in pediatric patients with neuromuscular scoliosis who often have comorbid movement disorders. Our prospective quality improvement study aims: (1) to determine if ULD CT without sedation is feasible in this patient group; (2) to quantify the radiation dose from ULD CT and compare it with preoperative spine radiographs (XR); and (3) to assess if ULD CT allows accurate anatomical assessment and intraoperative navigation given the prevalence of movement disorders.</p><p><strong>Methods: </strong>Children with neuromuscular scoliosis underwent spine XR and ULD CT scans. Chart reviews assessed disease etiology and comorbidities. Radiation dose was quantified through Monte-Carlo simulations giving dose indices and effective dose, with statistical analysis done using a paired student's t-test (α=0.05). CT image quality was assessed for its use in preoperative planning and intraoperative navigation.</p><p><strong>Results: </strong>Fourteen patients (5 males, 9 females, average age 14±3 y) participated. One patient needed sedation due to autism spectrum disorder and global developmental delay. The radiation dose for spine XR was 0.5±0.2 mSv, and ULD CT was 0.6±0.1 mSv. There was no statistically significant difference in radiation doses between methods. All ULD CT scans had adequate quality for preoperative assessment of pedicle diameter and orientation, obstacles impeding pedicle entry, S2 Alar-Iliac screw orientation, and intraoperative navigation.</p><p><strong>Conclusions: </strong>ULD CT without sedation is feasible for children with neuromuscular scoliosis. Radiation doses were comparable to standard radiographs. ULD CT provided accurate anatomical assessments and supported intraoperative navigation, proving beneficial despite movement disorders in these patients.</p><p><strong>Level of evidence: </strong>Level 2-Development of diagnostic criteria on basis of consecutive patients (with universally applied reference widely accepted standard).</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/BPO.0000000000002786\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/BPO.0000000000002786","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
"Ultralow-dose" CT Without Sedation in Pediatric Patients With Neuromuscular Scoliosis.
Background: Children with neuromuscular scoliosis undergoing scoliosis surgery face substantial rates of complications. To mitigate surgical risks such as blood loss in pediatric patients with neuromuscular scoliosis, this study focuses on enabling instrumentation planning for their abnormal vertebral and pelvic anatomy and osteopenia. This study assessed the feasibility of an "ultralow-dose" CT (ULD CT) protocol without sedation in pediatric patients with neuromuscular scoliosis who often have comorbid movement disorders. Our prospective quality improvement study aims: (1) to determine if ULD CT without sedation is feasible in this patient group; (2) to quantify the radiation dose from ULD CT and compare it with preoperative spine radiographs (XR); and (3) to assess if ULD CT allows accurate anatomical assessment and intraoperative navigation given the prevalence of movement disorders.
Methods: Children with neuromuscular scoliosis underwent spine XR and ULD CT scans. Chart reviews assessed disease etiology and comorbidities. Radiation dose was quantified through Monte-Carlo simulations giving dose indices and effective dose, with statistical analysis done using a paired student's t-test (α=0.05). CT image quality was assessed for its use in preoperative planning and intraoperative navigation.
Results: Fourteen patients (5 males, 9 females, average age 14±3 y) participated. One patient needed sedation due to autism spectrum disorder and global developmental delay. The radiation dose for spine XR was 0.5±0.2 mSv, and ULD CT was 0.6±0.1 mSv. There was no statistically significant difference in radiation doses between methods. All ULD CT scans had adequate quality for preoperative assessment of pedicle diameter and orientation, obstacles impeding pedicle entry, S2 Alar-Iliac screw orientation, and intraoperative navigation.
Conclusions: ULD CT without sedation is feasible for children with neuromuscular scoliosis. Radiation doses were comparable to standard radiographs. ULD CT provided accurate anatomical assessments and supported intraoperative navigation, proving beneficial despite movement disorders in these patients.
Level of evidence: Level 2-Development of diagnostic criteria on basis of consecutive patients (with universally applied reference widely accepted standard).
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.