通过结肠经内镜肠管逆行结肠成像有助于确认结肠镜检查困难的原因:病例报告。

IF 3 Q2 GASTROENTEROLOGY & HEPATOLOGY
Therapeutic Advances in Gastrointestinal Endoscopy Pub Date : 2024-08-15 eCollection Date: 2024-01-01 DOI:10.1177/26317745241270568
Xiaomeng Jiang, Runqing Wang, Haibo Sun, Faming Zhang
{"title":"通过结肠经内镜肠管逆行结肠成像有助于确认结肠镜检查困难的原因:病例报告。","authors":"Xiaomeng Jiang, Runqing Wang, Haibo Sun, Faming Zhang","doi":"10.1177/26317745241270568","DOIUrl":null,"url":null,"abstract":"<p><p>Numerous factors can contribute to a difficult colonoscopy, potentially leading to an incomplete procedure and overlooked lesions. Alternative strategies for handling difficult and incomplete colonoscopies should be considered. We present the case of an 85-year-old male who underwent a difficult colonoscopy, during which two expert endoscopists spent 1.5 h attempting various techniques but failed to intubate the cecum. Subsequently, colonic transendoscopic enteral tubing (TET) was performed. Abdominal plain film revealed tortuosity of the TET tube in the left abdomen corresponding to the distribution of the descending colon. Retrograde colon imaging was conducted by injecting a mixture of contrast medium and air into the colon via the TET tube. X-ray demonstrated well-developed visualization of the entire colon and terminal ileum. And evident elongation and tortuosity of the descending colon resembled an N-type folding pattern. The final diagnosis was determined as descending colon redundancy. Colonic TET combined with retrograde colon imaging through the TET tube may serve as an effective supplementary approach for identifying causes of difficult colonoscopy and improving diagnostic accuracy for bowel diseases when complete visualization is not achieved.</p>","PeriodicalId":40947,"journal":{"name":"Therapeutic Advances in Gastrointestinal Endoscopy","volume":"17 ","pages":"26317745241270568"},"PeriodicalIF":3.0000,"publicationDate":"2024-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11329917/pdf/","citationCount":"0","resultStr":"{\"title\":\"Retrograde colon imaging through colonic transendoscopic enteral tubing helps to confirm the cause of difficult colonoscopy: a case report.\",\"authors\":\"Xiaomeng Jiang, Runqing Wang, Haibo Sun, Faming Zhang\",\"doi\":\"10.1177/26317745241270568\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Numerous factors can contribute to a difficult colonoscopy, potentially leading to an incomplete procedure and overlooked lesions. Alternative strategies for handling difficult and incomplete colonoscopies should be considered. We present the case of an 85-year-old male who underwent a difficult colonoscopy, during which two expert endoscopists spent 1.5 h attempting various techniques but failed to intubate the cecum. Subsequently, colonic transendoscopic enteral tubing (TET) was performed. Abdominal plain film revealed tortuosity of the TET tube in the left abdomen corresponding to the distribution of the descending colon. Retrograde colon imaging was conducted by injecting a mixture of contrast medium and air into the colon via the TET tube. X-ray demonstrated well-developed visualization of the entire colon and terminal ileum. And evident elongation and tortuosity of the descending colon resembled an N-type folding pattern. The final diagnosis was determined as descending colon redundancy. Colonic TET combined with retrograde colon imaging through the TET tube may serve as an effective supplementary approach for identifying causes of difficult colonoscopy and improving diagnostic accuracy for bowel diseases when complete visualization is not achieved.</p>\",\"PeriodicalId\":40947,\"journal\":{\"name\":\"Therapeutic Advances in Gastrointestinal Endoscopy\",\"volume\":\"17 \",\"pages\":\"26317745241270568\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-08-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11329917/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutic Advances in Gastrointestinal Endoscopy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/26317745241270568\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Advances in Gastrointestinal Endoscopy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/26317745241270568","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

导致结肠镜检查困难的因素有很多,可能会导致检查过程不完整和病变被忽略。应考虑采用其他策略来处理困难和不完整的结肠镜检查。我们介绍了一位 85 岁男性的病例,他接受了一次困难的结肠镜检查,期间两位内镜专家花了 1.5 小时尝试各种技术,但未能插管盲肠。随后,他接受了结肠经内镜肠管插管术(TET)。腹部平片显示 TET 管在左腹部迂曲,与降结肠的分布相对应。通过 TET 管向结肠注入造影剂和空气的混合物,进行逆行结肠成像。X 光片显示整个结肠和回肠末端发育良好。降结肠的明显伸长和迂曲类似于 N 型折叠模式。最终诊断为降结肠赘生物。结肠 TET 结合通过 TET 管的逆行结肠成像可作为一种有效的辅助方法,用于确定结肠镜检查困难的原因,并在无法实现完全可视化的情况下提高肠道疾病的诊断准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Retrograde colon imaging through colonic transendoscopic enteral tubing helps to confirm the cause of difficult colonoscopy: a case report.

Numerous factors can contribute to a difficult colonoscopy, potentially leading to an incomplete procedure and overlooked lesions. Alternative strategies for handling difficult and incomplete colonoscopies should be considered. We present the case of an 85-year-old male who underwent a difficult colonoscopy, during which two expert endoscopists spent 1.5 h attempting various techniques but failed to intubate the cecum. Subsequently, colonic transendoscopic enteral tubing (TET) was performed. Abdominal plain film revealed tortuosity of the TET tube in the left abdomen corresponding to the distribution of the descending colon. Retrograde colon imaging was conducted by injecting a mixture of contrast medium and air into the colon via the TET tube. X-ray demonstrated well-developed visualization of the entire colon and terminal ileum. And evident elongation and tortuosity of the descending colon resembled an N-type folding pattern. The final diagnosis was determined as descending colon redundancy. Colonic TET combined with retrograde colon imaging through the TET tube may serve as an effective supplementary approach for identifying causes of difficult colonoscopy and improving diagnostic accuracy for bowel diseases when complete visualization is not achieved.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.80
自引率
0.00%
发文量
8
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信