James Williams, Daniel T Lammers, Andrew D Francis, Beau J Prey, Luke I Pumiglia, Matthew J Eckert, Yang Liu, Jason R Bingham, John M McClellan
{"title":"谁说夜间不能快速行动?院前医务人员使用新型超声夜视仪识别不可压缩的截肢出血。","authors":"James Williams, Daniel T Lammers, Andrew D Francis, Beau J Prey, Luke I Pumiglia, Matthew J Eckert, Yang Liu, Jason R Bingham, John M McClellan","doi":"10.1177/15533506241275288","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Early detection of abdominal hemorrhage via ultrasound has life-saving implications for military and civilian trauma. However, strict adherence to light discipline may prohibit the use of ultrasound devices in the deployed setting. Additionally, current night vision devices remain noncompatible with ultrasound technology. This study sought to assess an innovative night vision device with ultrasound capable picture-in-picture display via a intraabdominal hemorrhage model to identify noncompressible truncal hemorrhage in blackout conditions.</p><p><strong>Methods: </strong>8 post mortem fetal porcine specimens were used and divided into 2 groups: intrabdominal hemorrhage (n = 4) vs no hemorrhage (n = 4). Intrabdominal hemorrhage was modeled via direct injection of 200 mL of normal saline into the peritoneal cavity. Under blackout conditions, 5 participants performed a focused assessment with sonography for trauma (FAST) exam on each model using the prototype ultrasound-capable night vision device.</p><p><strong>Results: </strong>Of the 40 FAST exams performed, 95% (N = 38) resulted in the correct identification of intraabdominal hemorrhage. Of the incorrectly identified exams, both were false positives resulting in a 100% sensitivity, 90% specificity, 91% positive predictive value, and a 100% negative predictive value. All participants noted the novel device was easy to use and provided superior visualization for performing FAST exams under blackout conditions.</p><p><strong>Conclusion: </strong>The ultrasound-enabled night vision prototype demonstrated promising results in identifying noncompressible truncal hemorrhage while maintaining strict light discipline in blackout conditions. Further research efforts should be directed at assessing the ability of providers to perform procedures in blackout conditions using the ultrasound-enabled prototype night vision device.</p>","PeriodicalId":22095,"journal":{"name":"Surgical Innovation","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Who Says You can't go FAST at Night? Use of a Novel Ultrasound-Capable Night Vision Device for Prehospital Medical Personnel to Identify Noncompressible Truncal Hemorrhage.\",\"authors\":\"James Williams, Daniel T Lammers, Andrew D Francis, Beau J Prey, Luke I Pumiglia, Matthew J Eckert, Yang Liu, Jason R Bingham, John M McClellan\",\"doi\":\"10.1177/15533506241275288\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Early detection of abdominal hemorrhage via ultrasound has life-saving implications for military and civilian trauma. However, strict adherence to light discipline may prohibit the use of ultrasound devices in the deployed setting. Additionally, current night vision devices remain noncompatible with ultrasound technology. This study sought to assess an innovative night vision device with ultrasound capable picture-in-picture display via a intraabdominal hemorrhage model to identify noncompressible truncal hemorrhage in blackout conditions.</p><p><strong>Methods: </strong>8 post mortem fetal porcine specimens were used and divided into 2 groups: intrabdominal hemorrhage (n = 4) vs no hemorrhage (n = 4). Intrabdominal hemorrhage was modeled via direct injection of 200 mL of normal saline into the peritoneal cavity. Under blackout conditions, 5 participants performed a focused assessment with sonography for trauma (FAST) exam on each model using the prototype ultrasound-capable night vision device.</p><p><strong>Results: </strong>Of the 40 FAST exams performed, 95% (N = 38) resulted in the correct identification of intraabdominal hemorrhage. Of the incorrectly identified exams, both were false positives resulting in a 100% sensitivity, 90% specificity, 91% positive predictive value, and a 100% negative predictive value. All participants noted the novel device was easy to use and provided superior visualization for performing FAST exams under blackout conditions.</p><p><strong>Conclusion: </strong>The ultrasound-enabled night vision prototype demonstrated promising results in identifying noncompressible truncal hemorrhage while maintaining strict light discipline in blackout conditions. Further research efforts should be directed at assessing the ability of providers to perform procedures in blackout conditions using the ultrasound-enabled prototype night vision device.</p>\",\"PeriodicalId\":22095,\"journal\":{\"name\":\"Surgical Innovation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Surgical Innovation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15533506241275288\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Innovation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15533506241275288","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/16 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
Who Says You can't go FAST at Night? Use of a Novel Ultrasound-Capable Night Vision Device for Prehospital Medical Personnel to Identify Noncompressible Truncal Hemorrhage.
Background: Early detection of abdominal hemorrhage via ultrasound has life-saving implications for military and civilian trauma. However, strict adherence to light discipline may prohibit the use of ultrasound devices in the deployed setting. Additionally, current night vision devices remain noncompatible with ultrasound technology. This study sought to assess an innovative night vision device with ultrasound capable picture-in-picture display via a intraabdominal hemorrhage model to identify noncompressible truncal hemorrhage in blackout conditions.
Methods: 8 post mortem fetal porcine specimens were used and divided into 2 groups: intrabdominal hemorrhage (n = 4) vs no hemorrhage (n = 4). Intrabdominal hemorrhage was modeled via direct injection of 200 mL of normal saline into the peritoneal cavity. Under blackout conditions, 5 participants performed a focused assessment with sonography for trauma (FAST) exam on each model using the prototype ultrasound-capable night vision device.
Results: Of the 40 FAST exams performed, 95% (N = 38) resulted in the correct identification of intraabdominal hemorrhage. Of the incorrectly identified exams, both were false positives resulting in a 100% sensitivity, 90% specificity, 91% positive predictive value, and a 100% negative predictive value. All participants noted the novel device was easy to use and provided superior visualization for performing FAST exams under blackout conditions.
Conclusion: The ultrasound-enabled night vision prototype demonstrated promising results in identifying noncompressible truncal hemorrhage while maintaining strict light discipline in blackout conditions. Further research efforts should be directed at assessing the ability of providers to perform procedures in blackout conditions using the ultrasound-enabled prototype night vision device.
期刊介绍:
Surgical Innovation (SRI) is a peer-reviewed bi-monthly journal focusing on minimally invasive surgical techniques, new instruments such as laparoscopes and endoscopes, and new technologies. SRI prepares surgeons to think and work in "the operating room of the future" through learning new techniques, understanding and adapting to new technologies, maintaining surgical competencies, and applying surgical outcomes data to their practices. This journal is a member of the Committee on Publication Ethics (COPE).