Melissa A Wright, Michael O'Leary, Peter Johnston, Anand M Murthi
{"title":"解剖全肩关节成形术盂成形假体设计的进展。","authors":"Melissa A Wright, Michael O'Leary, Peter Johnston, Anand M Murthi","doi":"10.5435/JAAOS-D-23-00257","DOIUrl":null,"url":null,"abstract":"<p><p>Since the advent of Neer's total shoulder arthroplasty in 1974, glenoid implant design has evolved to optimize patient function and increase implant longevity. Glenoid loosening continues to be a major cause of total shoulder arthroplasty failure due to both patient and implant factors. The more recent development of posterior augmented glenoids, peg fixation with ingrowth potential, inlay implants, zoned conformity implants, and convertible glenoids have all shown promising results in improving glenoid fixation and survival in different clinical circumstances. The increased utilization of 3D CT scans, preoperative planning, and patient-specific instrumentation has paralleled innovation in glenoid implants with the aim of improving the accuracy of glenoid implant placement to further optimize patient function and implant longevity. Specific indications for the variety of glenoid implants available today are still being studied. The shoulder arthroplasty surgeon should consider patient and implant factors and patient goals when determining the appropriate implant for each individual.</p>","PeriodicalId":51098,"journal":{"name":"Journal of the American Academy of Orthopaedic Surgeons","volume":" ","pages":"56-64"},"PeriodicalIF":2.6000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Advances in Anatomic Total Shoulder Arthroplasty Glenoid Implant Design.\",\"authors\":\"Melissa A Wright, Michael O'Leary, Peter Johnston, Anand M Murthi\",\"doi\":\"10.5435/JAAOS-D-23-00257\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Since the advent of Neer's total shoulder arthroplasty in 1974, glenoid implant design has evolved to optimize patient function and increase implant longevity. Glenoid loosening continues to be a major cause of total shoulder arthroplasty failure due to both patient and implant factors. The more recent development of posterior augmented glenoids, peg fixation with ingrowth potential, inlay implants, zoned conformity implants, and convertible glenoids have all shown promising results in improving glenoid fixation and survival in different clinical circumstances. The increased utilization of 3D CT scans, preoperative planning, and patient-specific instrumentation has paralleled innovation in glenoid implants with the aim of improving the accuracy of glenoid implant placement to further optimize patient function and implant longevity. Specific indications for the variety of glenoid implants available today are still being studied. The shoulder arthroplasty surgeon should consider patient and implant factors and patient goals when determining the appropriate implant for each individual.</p>\",\"PeriodicalId\":51098,\"journal\":{\"name\":\"Journal of the American Academy of Orthopaedic Surgeons\",\"volume\":\" \",\"pages\":\"56-64\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2025-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Academy of Orthopaedic Surgeons\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5435/JAAOS-D-23-00257\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Academy of Orthopaedic Surgeons","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5435/JAAOS-D-23-00257","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Advances in Anatomic Total Shoulder Arthroplasty Glenoid Implant Design.
Since the advent of Neer's total shoulder arthroplasty in 1974, glenoid implant design has evolved to optimize patient function and increase implant longevity. Glenoid loosening continues to be a major cause of total shoulder arthroplasty failure due to both patient and implant factors. The more recent development of posterior augmented glenoids, peg fixation with ingrowth potential, inlay implants, zoned conformity implants, and convertible glenoids have all shown promising results in improving glenoid fixation and survival in different clinical circumstances. The increased utilization of 3D CT scans, preoperative planning, and patient-specific instrumentation has paralleled innovation in glenoid implants with the aim of improving the accuracy of glenoid implant placement to further optimize patient function and implant longevity. Specific indications for the variety of glenoid implants available today are still being studied. The shoulder arthroplasty surgeon should consider patient and implant factors and patient goals when determining the appropriate implant for each individual.
期刊介绍:
The Journal of the American Academy of Orthopaedic Surgeons was established in the fall of 1993 by the Academy in response to its membership’s demand for a clinical review journal. Two issues were published the first year, followed by six issues yearly from 1994 through 2004. In September 2005, JAAOS began publishing monthly issues.
Each issue includes richly illustrated peer-reviewed articles focused on clinical diagnosis and management. Special features in each issue provide commentary on developments in pharmacotherapeutics, materials and techniques, and computer applications.