利用机载 HyPlant 数据为 FLEX 确定最佳地面验证地点并量化不确定性 - 意大利案例研究

IF 5.7 Q1 ENVIRONMENTAL SCIENCES
Lena Katharina Jänicke, Rene Preusker, Jürgen Fischer
{"title":"利用机载 HyPlant 数据为 FLEX 确定最佳地面验证地点并量化不确定性 - 意大利案例研究","authors":"Lena Katharina Jänicke,&nbsp;Rene Preusker,&nbsp;Jürgen Fischer","doi":"10.1016/j.srs.2024.100155","DOIUrl":null,"url":null,"abstract":"<div><p>The Fluorescence Explorer (FLEX) satellite will carry the high-resolution Fluorescence Imaging Spectrometer (FLORIS) that measures the complete fluorescence spectrum emitted by chlorophyll of terrestrial vegetation. This small signal must be validated. One validation approach is comparing the fluorescence signal retrieved from satellite-based measurements with ground based measurements. However, the difference in spatial resolution of the satellite and ground-based instruments and a geolocation mismatch will result in differences in the detected signal and thus, in uncertainties of the validation strategy. In a case study, we identify a representative ground site for validating the fluorescence signal by analyzing surface reflectance measurements from an aeroplane.</p><p>We define requirements of representativeness for a validation ground site in vegetated areas. Based on those requirements, we identify a suitable position within a case study in central Italy using surface reflectance data from the airborne High-Performance Airborne Imaging Spectrometer (HyPlant) measured in summer 2018. The representativeness is quantified by the relative difference between the single HyPlant pixel representing a ground-based measurement and the averaged signal of several HyPlant pixels that mimics a FLORIS pixel. With this measure, we quantify the validation uncertainty due to spatial resolution and geolocation mismatch. The effect of the temporal evolution of the surface properties on the validation uncertainty due to spatial resolution is investigated.</p><p>We select the ground site position by minimizing the validation uncertainty due to spatial resolution. Especially for wavelengths larger than 700 nm, this uncertainty is smaller than 2 % for all different reference areas. The largest differences between ground-based like measurement and satellite-like measurement of the surface reflectance is due to geolocation mismatch. The uncertainty due the geolocation mismatch is very large for wavelengths smaller than 720 nm and moderate for wavelengths larger than 720 nm. Thus, the surface reflectance at the chosen position for the validation site is not homogeneous enough for validation purpose. Considering a reference area of 13.5 × 13.5 m<sup>2</sup>, we quantify temporal stable and small uncertainties for the spectral range between 720 and 800 nm. For an all-embracing validation of the surface reflectance of vegetated areas, the chosen site is not appropriate.</p></div>","PeriodicalId":101147,"journal":{"name":"Science of Remote Sensing","volume":"10 ","pages":"Article 100155"},"PeriodicalIF":5.7000,"publicationDate":"2024-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666017224000397/pdfft?md5=a24cd18d7ea0ce7c56e2003d521fde23&pid=1-s2.0-S2666017224000397-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Identification of an optimal ground-based validation site for FLEX and quantification of uncertainties using airborne HyPlant data - A case study in Italy\",\"authors\":\"Lena Katharina Jänicke,&nbsp;Rene Preusker,&nbsp;Jürgen Fischer\",\"doi\":\"10.1016/j.srs.2024.100155\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The Fluorescence Explorer (FLEX) satellite will carry the high-resolution Fluorescence Imaging Spectrometer (FLORIS) that measures the complete fluorescence spectrum emitted by chlorophyll of terrestrial vegetation. This small signal must be validated. One validation approach is comparing the fluorescence signal retrieved from satellite-based measurements with ground based measurements. However, the difference in spatial resolution of the satellite and ground-based instruments and a geolocation mismatch will result in differences in the detected signal and thus, in uncertainties of the validation strategy. In a case study, we identify a representative ground site for validating the fluorescence signal by analyzing surface reflectance measurements from an aeroplane.</p><p>We define requirements of representativeness for a validation ground site in vegetated areas. Based on those requirements, we identify a suitable position within a case study in central Italy using surface reflectance data from the airborne High-Performance Airborne Imaging Spectrometer (HyPlant) measured in summer 2018. The representativeness is quantified by the relative difference between the single HyPlant pixel representing a ground-based measurement and the averaged signal of several HyPlant pixels that mimics a FLORIS pixel. With this measure, we quantify the validation uncertainty due to spatial resolution and geolocation mismatch. The effect of the temporal evolution of the surface properties on the validation uncertainty due to spatial resolution is investigated.</p><p>We select the ground site position by minimizing the validation uncertainty due to spatial resolution. Especially for wavelengths larger than 700 nm, this uncertainty is smaller than 2 % for all different reference areas. The largest differences between ground-based like measurement and satellite-like measurement of the surface reflectance is due to geolocation mismatch. The uncertainty due the geolocation mismatch is very large for wavelengths smaller than 720 nm and moderate for wavelengths larger than 720 nm. Thus, the surface reflectance at the chosen position for the validation site is not homogeneous enough for validation purpose. Considering a reference area of 13.5 × 13.5 m<sup>2</sup>, we quantify temporal stable and small uncertainties for the spectral range between 720 and 800 nm. For an all-embracing validation of the surface reflectance of vegetated areas, the chosen site is not appropriate.</p></div>\",\"PeriodicalId\":101147,\"journal\":{\"name\":\"Science of Remote Sensing\",\"volume\":\"10 \",\"pages\":\"Article 100155\"},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-08-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666017224000397/pdfft?md5=a24cd18d7ea0ce7c56e2003d521fde23&pid=1-s2.0-S2666017224000397-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Science of Remote Sensing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666017224000397\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Science of Remote Sensing","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666017224000397","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

荧光探索者(FLEX)卫星将携带高分辨率荧光成像光谱仪(FLORIS),测量陆地植被叶绿素发出的完整荧光光谱。必须对这一微小信号进行验证。一种验证方法是将卫星测量获得的荧光信号与地面测量结果进行比较。然而,卫星和地面仪器空间分辨率的差异以及地理位置的不匹配会导致检测到的信号不同,从而给验证策略带来不确定性。在一项案例研究中,我们通过分析飞机的表面反射率测量结果,确定了一个具有代表性的地面站点,用于验证荧光信号。根据这些要求,我们利用 2018 年夏季测量的机载高性能机载成像光谱仪(HyPlant)表面反射率数据,在意大利中部的一个案例研究中确定了一个合适的位置。代表性通过代表地面测量的单个 HyPlant 像素与模拟 FLORIS 像素的多个 HyPlant 像素的平均信号之间的相对差异进行量化。通过这一指标,我们可以量化空间分辨率和地理位置不匹配造成的验证不确定性。我们通过最小化空间分辨率导致的验证不确定性来选择地面站点位置。特别是对于波长大于 700 纳米的波长,所有不同参考区域的验证不确定性都小于 2%。地基测量与卫星测量表面反射率的最大差异是地理定位不匹配造成的。波长小于 720 nm 时,地理定位失配造成的不确定性非常大,波长大于 720 nm 时,不确定性适中。因此,验证地点所选位置的表面反射率不够均匀,无法达到验证目的。考虑到参考区域为 13.5 × 13.5 m2,我们对 720 至 800 nm 光谱范围内的时间稳定和较小的不确定性进行了量化。对于植被区地表反射率的全面验证,所选地点并不合适。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Identification of an optimal ground-based validation site for FLEX and quantification of uncertainties using airborne HyPlant data - A case study in Italy

The Fluorescence Explorer (FLEX) satellite will carry the high-resolution Fluorescence Imaging Spectrometer (FLORIS) that measures the complete fluorescence spectrum emitted by chlorophyll of terrestrial vegetation. This small signal must be validated. One validation approach is comparing the fluorescence signal retrieved from satellite-based measurements with ground based measurements. However, the difference in spatial resolution of the satellite and ground-based instruments and a geolocation mismatch will result in differences in the detected signal and thus, in uncertainties of the validation strategy. In a case study, we identify a representative ground site for validating the fluorescence signal by analyzing surface reflectance measurements from an aeroplane.

We define requirements of representativeness for a validation ground site in vegetated areas. Based on those requirements, we identify a suitable position within a case study in central Italy using surface reflectance data from the airborne High-Performance Airborne Imaging Spectrometer (HyPlant) measured in summer 2018. The representativeness is quantified by the relative difference between the single HyPlant pixel representing a ground-based measurement and the averaged signal of several HyPlant pixels that mimics a FLORIS pixel. With this measure, we quantify the validation uncertainty due to spatial resolution and geolocation mismatch. The effect of the temporal evolution of the surface properties on the validation uncertainty due to spatial resolution is investigated.

We select the ground site position by minimizing the validation uncertainty due to spatial resolution. Especially for wavelengths larger than 700 nm, this uncertainty is smaller than 2 % for all different reference areas. The largest differences between ground-based like measurement and satellite-like measurement of the surface reflectance is due to geolocation mismatch. The uncertainty due the geolocation mismatch is very large for wavelengths smaller than 720 nm and moderate for wavelengths larger than 720 nm. Thus, the surface reflectance at the chosen position for the validation site is not homogeneous enough for validation purpose. Considering a reference area of 13.5 × 13.5 m2, we quantify temporal stable and small uncertainties for the spectral range between 720 and 800 nm. For an all-embracing validation of the surface reflectance of vegetated areas, the chosen site is not appropriate.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
12.20
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信