Renjie Huang, Jianting Du, Guobing Xu, Xian Gong, Jiekun Qian, Shuxing Chen, Bin Zheng, Chun Chen, Zhang Yang
{"title":"三维打印模型与近红外荧光技术在视频辅助胸腔镜手术分段切除术中的应用:单中心倾向得分匹配分析。","authors":"Renjie Huang, Jianting Du, Guobing Xu, Xian Gong, Jiekun Qian, Shuxing Chen, Bin Zheng, Chun Chen, Zhang Yang","doi":"10.21037/jtd-24-489","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The combination of three-dimensional printing (3DP) technology and near-infrared fluorescence (NIF) technology using indocyanine green (ICG) has demonstrated significant potential in enhancing surgical margin and safety, as well as simplifying segmental resection. However, there is limited literature available on the integrated use of these techniques. The current study assessed the effectiveness and value of integrating 3DP-NIF technologies in the perioperative outcomes of thoracoscopic segmental lung resection.</p><p><strong>Methods: </strong>This single-center, retrospective study recruited 165 patients with pulmonary nodules who underwent thoracoscopic segmentectomy. Eligible patients were categorized into two groups: the 3DP-NIF group (71 patients) treated with a combination of 3DP-NIF technology, and the three-dimensional computed tomography bronchography and angiography with modified inflation-deflation (3D-CTBA-ID) group (94 patients). Following rigorous propensity-score matching (PSM) analysis (1:1 ratio), perioperative outcomes between these two approaches were compared.</p><p><strong>Results: </strong>Sixty-six patients were successfully matched in each group. In the 3D-CTBA-ID group, inadequate visualization of segmental planes was noted in 14 cases, compared to only five cases in the 3DP-NIF group (P=0.03). In addition, the 3DP-NIF group demonstrated a shorter time for clear intersegmental boundary line (IBL) presentation {9 [8, 10] <i>vs.</i> 1,860 [1,380, 1,920] s} (P<0.001), and shorter operative time (134.09±34.9 <i>vs.</i> 163.47±49.4 min) (P<0.001), postoperative drainage time (P<0.001), and postoperative hospital stay (P=0.002) compared to the 3D-CTBA-ID group. Furthermore, the incidence of postoperative air leak was higher in the 3D-CTBA-ID group than in the 3DP-NIF group (33.3% <i>vs.</i> 7.6%, P<0.001).</p><p><strong>Conclusions: </strong>The combination of 3DP-NIF technologies served as a reliable technical safeguard, ensuring the safe and efficient execution of thoracoscopic pulmonary segmentectomy.</p>","PeriodicalId":17542,"journal":{"name":"Journal of thoracic disease","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11320237/pdf/","citationCount":"0","resultStr":"{\"title\":\"Application of three-dimensional printed models with near-infrared fluorescence technology in video-assisted thoracoscopic surgery segmentectomy: a single-center propensity-score matching analysis.\",\"authors\":\"Renjie Huang, Jianting Du, Guobing Xu, Xian Gong, Jiekun Qian, Shuxing Chen, Bin Zheng, Chun Chen, Zhang Yang\",\"doi\":\"10.21037/jtd-24-489\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The combination of three-dimensional printing (3DP) technology and near-infrared fluorescence (NIF) technology using indocyanine green (ICG) has demonstrated significant potential in enhancing surgical margin and safety, as well as simplifying segmental resection. However, there is limited literature available on the integrated use of these techniques. The current study assessed the effectiveness and value of integrating 3DP-NIF technologies in the perioperative outcomes of thoracoscopic segmental lung resection.</p><p><strong>Methods: </strong>This single-center, retrospective study recruited 165 patients with pulmonary nodules who underwent thoracoscopic segmentectomy. Eligible patients were categorized into two groups: the 3DP-NIF group (71 patients) treated with a combination of 3DP-NIF technology, and the three-dimensional computed tomography bronchography and angiography with modified inflation-deflation (3D-CTBA-ID) group (94 patients). Following rigorous propensity-score matching (PSM) analysis (1:1 ratio), perioperative outcomes between these two approaches were compared.</p><p><strong>Results: </strong>Sixty-six patients were successfully matched in each group. In the 3D-CTBA-ID group, inadequate visualization of segmental planes was noted in 14 cases, compared to only five cases in the 3DP-NIF group (P=0.03). In addition, the 3DP-NIF group demonstrated a shorter time for clear intersegmental boundary line (IBL) presentation {9 [8, 10] <i>vs.</i> 1,860 [1,380, 1,920] s} (P<0.001), and shorter operative time (134.09±34.9 <i>vs.</i> 163.47±49.4 min) (P<0.001), postoperative drainage time (P<0.001), and postoperative hospital stay (P=0.002) compared to the 3D-CTBA-ID group. Furthermore, the incidence of postoperative air leak was higher in the 3D-CTBA-ID group than in the 3DP-NIF group (33.3% <i>vs.</i> 7.6%, P<0.001).</p><p><strong>Conclusions: </strong>The combination of 3DP-NIF technologies served as a reliable technical safeguard, ensuring the safe and efficient execution of thoracoscopic pulmonary segmentectomy.</p>\",\"PeriodicalId\":17542,\"journal\":{\"name\":\"Journal of thoracic disease\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11320237/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of thoracic disease\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.21037/jtd-24-489\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RESPIRATORY SYSTEM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of thoracic disease","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/jtd-24-489","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
Application of three-dimensional printed models with near-infrared fluorescence technology in video-assisted thoracoscopic surgery segmentectomy: a single-center propensity-score matching analysis.
Background: The combination of three-dimensional printing (3DP) technology and near-infrared fluorescence (NIF) technology using indocyanine green (ICG) has demonstrated significant potential in enhancing surgical margin and safety, as well as simplifying segmental resection. However, there is limited literature available on the integrated use of these techniques. The current study assessed the effectiveness and value of integrating 3DP-NIF technologies in the perioperative outcomes of thoracoscopic segmental lung resection.
Methods: This single-center, retrospective study recruited 165 patients with pulmonary nodules who underwent thoracoscopic segmentectomy. Eligible patients were categorized into two groups: the 3DP-NIF group (71 patients) treated with a combination of 3DP-NIF technology, and the three-dimensional computed tomography bronchography and angiography with modified inflation-deflation (3D-CTBA-ID) group (94 patients). Following rigorous propensity-score matching (PSM) analysis (1:1 ratio), perioperative outcomes between these two approaches were compared.
Results: Sixty-six patients were successfully matched in each group. In the 3D-CTBA-ID group, inadequate visualization of segmental planes was noted in 14 cases, compared to only five cases in the 3DP-NIF group (P=0.03). In addition, the 3DP-NIF group demonstrated a shorter time for clear intersegmental boundary line (IBL) presentation {9 [8, 10] vs. 1,860 [1,380, 1,920] s} (P<0.001), and shorter operative time (134.09±34.9 vs. 163.47±49.4 min) (P<0.001), postoperative drainage time (P<0.001), and postoperative hospital stay (P=0.002) compared to the 3D-CTBA-ID group. Furthermore, the incidence of postoperative air leak was higher in the 3D-CTBA-ID group than in the 3DP-NIF group (33.3% vs. 7.6%, P<0.001).
Conclusions: The combination of 3DP-NIF technologies served as a reliable technical safeguard, ensuring the safe and efficient execution of thoracoscopic pulmonary segmentectomy.
期刊介绍:
The Journal of Thoracic Disease (JTD, J Thorac Dis, pISSN: 2072-1439; eISSN: 2077-6624) was founded in Dec 2009, and indexed in PubMed in Dec 2011 and Science Citation Index SCI in Feb 2013. It is published quarterly (Dec 2009- Dec 2011), bimonthly (Jan 2012 - Dec 2013), monthly (Jan. 2014-) and openly distributed worldwide. JTD received its impact factor of 2.365 for the year 2016. JTD publishes manuscripts that describe new findings and provide current, practical information on the diagnosis and treatment of conditions related to thoracic disease. All the submission and reviewing are conducted electronically so that rapid review is assured.