{"title":"量化存在同步凝汽器时基于逆变器的弱电网的稳定性","authors":"Sajjad Hadavi;Nabil Mohammed;Ali Mehrizi-Sani;Behrooz Bahrani","doi":"10.1109/OAJPE.2024.3428365","DOIUrl":null,"url":null,"abstract":"The high penetration of renewable energy resources, integrated via power electronic inverters, into weak and low-inertia grids has led to the emergence of new challenges within power systems. The absence of native inertia in inverter-based resources (IBRs), in contrast to fossil-fuel-based generators, can result in sustained oscillations and instability. Synchronous Condensers (SynCons) are being considered as a reborn technology to address the challenges associated with system strengthening and inertia support in IBR-dominant power systems. Despite the well-established nature of SynCons, an additional assessment is necessary to analyze the stability of a weak grid with a high penetration of renewable resources, particularly in the presence of SynCons. This paper proposes a quantitative index for the stability analysis of a system incorporating black-boxed IBRs and SynCons. The proposed index is derived from impedance-based stability analysis. The impact of a SynCon on the proposed stability index is evaluated in a single-machine infinite-bus system, and its accuracy is further verified in an IEEE 39-bus system. Additionally, the findings are corroborated through time-domain simulation tests conducted in PSCAD/EMTDC software.","PeriodicalId":56187,"journal":{"name":"IEEE Open Access Journal of Power and Energy","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10598181","citationCount":"0","resultStr":"{\"title\":\"Quantifying Stability in Inverter-Based Weak Grids in the Presence of Synchronous Condensers\",\"authors\":\"Sajjad Hadavi;Nabil Mohammed;Ali Mehrizi-Sani;Behrooz Bahrani\",\"doi\":\"10.1109/OAJPE.2024.3428365\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The high penetration of renewable energy resources, integrated via power electronic inverters, into weak and low-inertia grids has led to the emergence of new challenges within power systems. The absence of native inertia in inverter-based resources (IBRs), in contrast to fossil-fuel-based generators, can result in sustained oscillations and instability. Synchronous Condensers (SynCons) are being considered as a reborn technology to address the challenges associated with system strengthening and inertia support in IBR-dominant power systems. Despite the well-established nature of SynCons, an additional assessment is necessary to analyze the stability of a weak grid with a high penetration of renewable resources, particularly in the presence of SynCons. This paper proposes a quantitative index for the stability analysis of a system incorporating black-boxed IBRs and SynCons. The proposed index is derived from impedance-based stability analysis. The impact of a SynCon on the proposed stability index is evaluated in a single-machine infinite-bus system, and its accuracy is further verified in an IEEE 39-bus system. Additionally, the findings are corroborated through time-domain simulation tests conducted in PSCAD/EMTDC software.\",\"PeriodicalId\":56187,\"journal\":{\"name\":\"IEEE Open Access Journal of Power and Energy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10598181\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Open Access Journal of Power and Energy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10598181/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Open Access Journal of Power and Energy","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10598181/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

通过电力电子逆变器集成到弱电网和低惯性电网中的可再生能源的高渗透率导致电力系统出现了新的挑战。与基于化石燃料的发电机相比,基于逆变器的资源(IBRs)缺乏原生惯性,这可能会导致持续振荡和不稳定。同步冷凝器(SynCons)被认为是一种重生技术,可解决以 IBR 为主导的电力系统中与系统强化和惯性支持相关的挑战。尽管同步凝汽器的特性已得到证实,但仍有必要进行额外的评估,以分析可再生资源渗透率较高的弱电网的稳定性,尤其是在存在同步凝汽器的情况下。本文提出了一种定量指标,用于分析包含黑盒 IBR 和 SynCons 的系统的稳定性。提出的指标来自基于阻抗的稳定性分析。在单机无限总线系统中评估了 SynCon 对所提出的稳定性指数的影响,并在 IEEE 39 总线系统中进一步验证了其准确性。此外,通过 PSCAD/EMTDC 软件进行的时域仿真测试也证实了上述结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Quantifying Stability in Inverter-Based Weak Grids in the Presence of Synchronous Condensers
The high penetration of renewable energy resources, integrated via power electronic inverters, into weak and low-inertia grids has led to the emergence of new challenges within power systems. The absence of native inertia in inverter-based resources (IBRs), in contrast to fossil-fuel-based generators, can result in sustained oscillations and instability. Synchronous Condensers (SynCons) are being considered as a reborn technology to address the challenges associated with system strengthening and inertia support in IBR-dominant power systems. Despite the well-established nature of SynCons, an additional assessment is necessary to analyze the stability of a weak grid with a high penetration of renewable resources, particularly in the presence of SynCons. This paper proposes a quantitative index for the stability analysis of a system incorporating black-boxed IBRs and SynCons. The proposed index is derived from impedance-based stability analysis. The impact of a SynCon on the proposed stability index is evaluated in a single-machine infinite-bus system, and its accuracy is further verified in an IEEE 39-bus system. Additionally, the findings are corroborated through time-domain simulation tests conducted in PSCAD/EMTDC software.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.80
自引率
5.30%
发文量
45
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信