地高辛样免疫反应因子明显干扰酶免疫测定。

J A Karboski, P J Godley, P A Frohna, M W Horton, W J Reitmeyer
{"title":"地高辛样免疫反应因子明显干扰酶免疫测定。","authors":"J A Karboski,&nbsp;P J Godley,&nbsp;P A Frohna,&nbsp;M W Horton,&nbsp;W J Reitmeyer","doi":"10.1177/106002808802200913","DOIUrl":null,"url":null,"abstract":"<p><p>A case in which digoxin-like immunoreactive factors (DLIF) interfered with an enzyme immunoassay in a patient with renal insufficiency is reported. A 79-year-old woman was found to have a serum digoxin concentration (SDC) determined by enzyme immunoassay of 5.0 ng/ml. Although all subsequent SDC determined by the enzyme immunoassay system were elevated, identical samples run on a fluorescence polarization immunoassay revealed SDC within the therapeutic range. Marked DLIF-related assay interference has been reported to occur with some digoxin assays; however, the enzyme immunoassay methods have never been reported to cross-react to the magnitude seen in this case.</p>","PeriodicalId":77709,"journal":{"name":"Drug intelligence & clinical pharmacy","volume":"22 9","pages":"703-5"},"PeriodicalIF":0.0000,"publicationDate":"1988-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/106002808802200913","citationCount":"7","resultStr":"{\"title\":\"Marked digoxin-like immunoreactive factor interference with an enzyme immunoassay.\",\"authors\":\"J A Karboski,&nbsp;P J Godley,&nbsp;P A Frohna,&nbsp;M W Horton,&nbsp;W J Reitmeyer\",\"doi\":\"10.1177/106002808802200913\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A case in which digoxin-like immunoreactive factors (DLIF) interfered with an enzyme immunoassay in a patient with renal insufficiency is reported. A 79-year-old woman was found to have a serum digoxin concentration (SDC) determined by enzyme immunoassay of 5.0 ng/ml. Although all subsequent SDC determined by the enzyme immunoassay system were elevated, identical samples run on a fluorescence polarization immunoassay revealed SDC within the therapeutic range. Marked DLIF-related assay interference has been reported to occur with some digoxin assays; however, the enzyme immunoassay methods have never been reported to cross-react to the magnitude seen in this case.</p>\",\"PeriodicalId\":77709,\"journal\":{\"name\":\"Drug intelligence & clinical pharmacy\",\"volume\":\"22 9\",\"pages\":\"703-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/106002808802200913\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Drug intelligence & clinical pharmacy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/106002808802200913\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug intelligence & clinical pharmacy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/106002808802200913","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

报告一例地高辛样免疫反应因子(DLIF)干扰肾功能不全患者的酶免疫测定。一名79岁妇女经酶免疫测定血清地高辛浓度(SDC)为5.0 ng/ml。虽然所有随后由酶免疫分析系统测定的SDC升高,但在荧光偏振免疫分析上运行的相同样品显示SDC在治疗范围内。据报道,在一些地高辛测定中出现了明显的dlifs相关的测定干扰;然而,酶免疫测定方法从未报道过交叉反应达到本病例所见的程度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Marked digoxin-like immunoreactive factor interference with an enzyme immunoassay.

A case in which digoxin-like immunoreactive factors (DLIF) interfered with an enzyme immunoassay in a patient with renal insufficiency is reported. A 79-year-old woman was found to have a serum digoxin concentration (SDC) determined by enzyme immunoassay of 5.0 ng/ml. Although all subsequent SDC determined by the enzyme immunoassay system were elevated, identical samples run on a fluorescence polarization immunoassay revealed SDC within the therapeutic range. Marked DLIF-related assay interference has been reported to occur with some digoxin assays; however, the enzyme immunoassay methods have never been reported to cross-react to the magnitude seen in this case.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信