{"title":"全腕关节置换术后桡骨假体周围骨折:病例报告","authors":"Ryan Quinn, Matthew Robinson","doi":"10.1016/j.tcr.2024.101089","DOIUrl":null,"url":null,"abstract":"<div><p>Total wrist arthroplasty (TWA) is indicated in select low demand patients with pan-carpal arthritis to decrease pain and preserve motion. Complications of TWA are well described including aseptic loosening, superficial and deep infection, wound issues, component dislocation, stiffness, and both intraoperative and post-operative fracture. With 4th generation implant designs, the incidence of many of these complications have decreased, but these complications remain challenging to address. In particular, sparse literature is available for the treatment of periprosthetic radius fractures after TWA. This report describes the management of an open, periprosthetic distal third radius fracture 18 months after index TWA in a medically complex 53-year-old female with lag screw fixation and a dorsal wrist spanning plate (DSP).</p></div>","PeriodicalId":23291,"journal":{"name":"Trauma Case Reports","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2352644024001122/pdfft?md5=efe22d07523188f6059fe3eeeaf03fcb&pid=1-s2.0-S2352644024001122-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Periprosthetic radius fracture after total wrist arthroplasty: A case report\",\"authors\":\"Ryan Quinn, Matthew Robinson\",\"doi\":\"10.1016/j.tcr.2024.101089\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Total wrist arthroplasty (TWA) is indicated in select low demand patients with pan-carpal arthritis to decrease pain and preserve motion. Complications of TWA are well described including aseptic loosening, superficial and deep infection, wound issues, component dislocation, stiffness, and both intraoperative and post-operative fracture. With 4th generation implant designs, the incidence of many of these complications have decreased, but these complications remain challenging to address. In particular, sparse literature is available for the treatment of periprosthetic radius fractures after TWA. This report describes the management of an open, periprosthetic distal third radius fracture 18 months after index TWA in a medically complex 53-year-old female with lag screw fixation and a dorsal wrist spanning plate (DSP).</p></div>\",\"PeriodicalId\":23291,\"journal\":{\"name\":\"Trauma Case Reports\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2352644024001122/pdfft?md5=efe22d07523188f6059fe3eeeaf03fcb&pid=1-s2.0-S2352644024001122-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Trauma Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352644024001122\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trauma Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352644024001122","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
摘要
全腕关节置换术(TWA)适用于选择性低需求的泛腕关节炎患者,以减轻疼痛并保持运动功能。全腕关节置换术的并发症已得到充分描述,包括无菌性松动、表皮和深部感染、伤口问题、组件脱位、僵硬以及术中和术后骨折。随着第四代种植体设计的出现,许多并发症的发生率都有所下降,但这些并发症的解决仍具有挑战性。特别是,关于TWA术后桡骨假体周围骨折的治疗文献很少。本报告描述了一名病情复杂的 53 岁女性在指数 TWA 18 个月后发生的开放性、假体周围第三桡骨远端骨折的治疗情况,采用的是滞后螺钉固定和腕关节背板 (DSP)。
Periprosthetic radius fracture after total wrist arthroplasty: A case report
Total wrist arthroplasty (TWA) is indicated in select low demand patients with pan-carpal arthritis to decrease pain and preserve motion. Complications of TWA are well described including aseptic loosening, superficial and deep infection, wound issues, component dislocation, stiffness, and both intraoperative and post-operative fracture. With 4th generation implant designs, the incidence of many of these complications have decreased, but these complications remain challenging to address. In particular, sparse literature is available for the treatment of periprosthetic radius fractures after TWA. This report describes the management of an open, periprosthetic distal third radius fracture 18 months after index TWA in a medically complex 53-year-old female with lag screw fixation and a dorsal wrist spanning plate (DSP).
期刊介绍:
Trauma Case Reports is the only open access, online journal dedicated to the publication of case reports in all aspects of trauma care and accident surgery. Case reports on all aspects of trauma management, surgical procedures for all tissues, resuscitation, anaesthesia and trauma and tissue healing will be considered for publication by the international editorial team and will be subject to peer review. Bringing together these cases from an international authorship will shed light on surgical problems and help in their effective resolution.