{"title":"癌症治疗中植入式端口的单中心分析:五年疗效和安全性评估","authors":"Adel Abou-Mrad, Luigi Marano, Rodolfo J Oviedo","doi":"10.3390/cancers16162802","DOIUrl":null,"url":null,"abstract":"Background: Daily clinical practice requires repeated and prolonged venous access for delivering chemotherapy, antibiotics, antivirals, parenteral nutrition, or blood transfusions. This study aimed to investigate the performance and the safety of totally implantable vascular access devices (TIVADs) over a 5-year follow-up period through a standardized well-trained surgical technique and patient management under local anesthesia. Methods: In a retrospective, observational, and monocentric study, 70 patients receiving POLYSITE® TIVADs for chemotherapy were included. The safety endpoints focused on the rate of perioperative, short-term, and long-term complications. The performance endpoints included vein identification for device insertion and procedural success rate. Results: The study demonstrated no perioperative or short-term complications related to the TIVADs. One (1.4%) complication related to device manipulation was identified as catheter flipping, which led to catheter adjustment 56 days post-placement. Moreover, one (1.4%) infection due to usage conditions was observed, leading to TIVAD removal 3 years and 4 months post-surgery. Catheter placement occurred in cephalic veins (71.4%), subclavian veins (20%), and internal jugular veins (8.6%). The procedural success rate was 100%. Overall, the implantable ports typically remained in place for an average of 22.4 months. Conclusions: This study confirmed the TIVADs’ performance and safety, underscored by low complication rates compared to published data, thereby emphasizing its potential and compelling significance for enhancing routine clinical practice using a standardized well-trained surgical technique and patient management.","PeriodicalId":504676,"journal":{"name":"Cancers","volume":"12 12","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Monocentric Analysis of Implantable Ports in Cancer Treatment: Five-Year Efficacy and Safety Evaluation\",\"authors\":\"Adel Abou-Mrad, Luigi Marano, Rodolfo J Oviedo\",\"doi\":\"10.3390/cancers16162802\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Daily clinical practice requires repeated and prolonged venous access for delivering chemotherapy, antibiotics, antivirals, parenteral nutrition, or blood transfusions. This study aimed to investigate the performance and the safety of totally implantable vascular access devices (TIVADs) over a 5-year follow-up period through a standardized well-trained surgical technique and patient management under local anesthesia. Methods: In a retrospective, observational, and monocentric study, 70 patients receiving POLYSITE® TIVADs for chemotherapy were included. The safety endpoints focused on the rate of perioperative, short-term, and long-term complications. The performance endpoints included vein identification for device insertion and procedural success rate. Results: The study demonstrated no perioperative or short-term complications related to the TIVADs. One (1.4%) complication related to device manipulation was identified as catheter flipping, which led to catheter adjustment 56 days post-placement. Moreover, one (1.4%) infection due to usage conditions was observed, leading to TIVAD removal 3 years and 4 months post-surgery. Catheter placement occurred in cephalic veins (71.4%), subclavian veins (20%), and internal jugular veins (8.6%). The procedural success rate was 100%. Overall, the implantable ports typically remained in place for an average of 22.4 months. Conclusions: This study confirmed the TIVADs’ performance and safety, underscored by low complication rates compared to published data, thereby emphasizing its potential and compelling significance for enhancing routine clinical practice using a standardized well-trained surgical technique and patient management.\",\"PeriodicalId\":504676,\"journal\":{\"name\":\"Cancers\",\"volume\":\"12 12\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cancers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/cancers16162802\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cancers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/cancers16162802","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Monocentric Analysis of Implantable Ports in Cancer Treatment: Five-Year Efficacy and Safety Evaluation
Background: Daily clinical practice requires repeated and prolonged venous access for delivering chemotherapy, antibiotics, antivirals, parenteral nutrition, or blood transfusions. This study aimed to investigate the performance and the safety of totally implantable vascular access devices (TIVADs) over a 5-year follow-up period through a standardized well-trained surgical technique and patient management under local anesthesia. Methods: In a retrospective, observational, and monocentric study, 70 patients receiving POLYSITE® TIVADs for chemotherapy were included. The safety endpoints focused on the rate of perioperative, short-term, and long-term complications. The performance endpoints included vein identification for device insertion and procedural success rate. Results: The study demonstrated no perioperative or short-term complications related to the TIVADs. One (1.4%) complication related to device manipulation was identified as catheter flipping, which led to catheter adjustment 56 days post-placement. Moreover, one (1.4%) infection due to usage conditions was observed, leading to TIVAD removal 3 years and 4 months post-surgery. Catheter placement occurred in cephalic veins (71.4%), subclavian veins (20%), and internal jugular veins (8.6%). The procedural success rate was 100%. Overall, the implantable ports typically remained in place for an average of 22.4 months. Conclusions: This study confirmed the TIVADs’ performance and safety, underscored by low complication rates compared to published data, thereby emphasizing its potential and compelling significance for enhancing routine clinical practice using a standardized well-trained surgical technique and patient management.