Wanting Xie, Liying Zhou, Jinting Liu, Ziyi Li, Zehong Li, Wen Gao, Yan Shi
{"title":"如何从真实人体毛发中追踪非法电子烟中的依托咪酯:识别、定量和多因素分析。","authors":"Wanting Xie, Liying Zhou, Jinting Liu, Ziyi Li, Zehong Li, Wen Gao, Yan Shi","doi":"10.1007/s11419-024-00698-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The abusive consumption of illegal E-cigarettes containing etomidate (ET) can have a significant impact on public mental and physical well-being. The purpose of this study is to establish a rapid quantitative method using ultra-high-performance liquid chromatography/tandem mass spectrometry (UHPLC-MS/MS) for the targeted screening of etomidate (ET) and its metabolite etomidate acid (ETA) in hair samples.</p><p><strong>Methods: </strong>A 1 mL methanol solution containing the internal standard ET-d<sub>5</sub> at a concentration of 50 pg/mg was added to 20 mg of hair and milled below 4 °C. After centrifugation, 5 μL of the supernatant was injected into a UHPLC-MS/MS system.</p><p><strong>Results: </strong>The limit of detection (LOD) and limit of quantification (LOQ) were determined to be 1 pg/mg and 10 pg/mg, respectively, for ET, and 10 pg/mg and 25 pg/mg, respectively, for ETA. Calibration curves for all analytes showed good linearity (r > 0.997), indicating a reliable method. Accuracies were between 92.12% and 110.72%. Intra-day and inter-day precision for all analytes at all concentration levels were below 10.13%. Analyte recoveries ranged from 86.90% to 101.43%, with a matrix effect ranging from -18.55% to -14.93%.</p><p><strong>Conclusions: </strong>The validated method was successfully used to analyze 105 hair samples from suspected ET users. Of these, 50 tested positive for ET and 43 tested positive for ETA above the LOQ. This demonstrates the effectiveness of the developed UHPLC-MS/MS method in detecting ET and ETA in hair samples, which could be instrumental in addressing the issue of illegal E-cigarette abuse and its impact on public health.</p>","PeriodicalId":12329,"journal":{"name":"Forensic Toxicology","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"How to trace etomidate in illegal E-cigarettes from authentic human hair: identification, quantification and multiple-factor analysis.\",\"authors\":\"Wanting Xie, Liying Zhou, Jinting Liu, Ziyi Li, Zehong Li, Wen Gao, Yan Shi\",\"doi\":\"10.1007/s11419-024-00698-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The abusive consumption of illegal E-cigarettes containing etomidate (ET) can have a significant impact on public mental and physical well-being. The purpose of this study is to establish a rapid quantitative method using ultra-high-performance liquid chromatography/tandem mass spectrometry (UHPLC-MS/MS) for the targeted screening of etomidate (ET) and its metabolite etomidate acid (ETA) in hair samples.</p><p><strong>Methods: </strong>A 1 mL methanol solution containing the internal standard ET-d<sub>5</sub> at a concentration of 50 pg/mg was added to 20 mg of hair and milled below 4 °C. After centrifugation, 5 μL of the supernatant was injected into a UHPLC-MS/MS system.</p><p><strong>Results: </strong>The limit of detection (LOD) and limit of quantification (LOQ) were determined to be 1 pg/mg and 10 pg/mg, respectively, for ET, and 10 pg/mg and 25 pg/mg, respectively, for ETA. Calibration curves for all analytes showed good linearity (r > 0.997), indicating a reliable method. Accuracies were between 92.12% and 110.72%. Intra-day and inter-day precision for all analytes at all concentration levels were below 10.13%. Analyte recoveries ranged from 86.90% to 101.43%, with a matrix effect ranging from -18.55% to -14.93%.</p><p><strong>Conclusions: </strong>The validated method was successfully used to analyze 105 hair samples from suspected ET users. Of these, 50 tested positive for ET and 43 tested positive for ETA above the LOQ. This demonstrates the effectiveness of the developed UHPLC-MS/MS method in detecting ET and ETA in hair samples, which could be instrumental in addressing the issue of illegal E-cigarette abuse and its impact on public health.</p>\",\"PeriodicalId\":12329,\"journal\":{\"name\":\"Forensic Toxicology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-08-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Forensic Toxicology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11419-024-00698-w\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"TOXICOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Forensic Toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11419-024-00698-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"TOXICOLOGY","Score":null,"Total":0}
How to trace etomidate in illegal E-cigarettes from authentic human hair: identification, quantification and multiple-factor analysis.
Purpose: The abusive consumption of illegal E-cigarettes containing etomidate (ET) can have a significant impact on public mental and physical well-being. The purpose of this study is to establish a rapid quantitative method using ultra-high-performance liquid chromatography/tandem mass spectrometry (UHPLC-MS/MS) for the targeted screening of etomidate (ET) and its metabolite etomidate acid (ETA) in hair samples.
Methods: A 1 mL methanol solution containing the internal standard ET-d5 at a concentration of 50 pg/mg was added to 20 mg of hair and milled below 4 °C. After centrifugation, 5 μL of the supernatant was injected into a UHPLC-MS/MS system.
Results: The limit of detection (LOD) and limit of quantification (LOQ) were determined to be 1 pg/mg and 10 pg/mg, respectively, for ET, and 10 pg/mg and 25 pg/mg, respectively, for ETA. Calibration curves for all analytes showed good linearity (r > 0.997), indicating a reliable method. Accuracies were between 92.12% and 110.72%. Intra-day and inter-day precision for all analytes at all concentration levels were below 10.13%. Analyte recoveries ranged from 86.90% to 101.43%, with a matrix effect ranging from -18.55% to -14.93%.
Conclusions: The validated method was successfully used to analyze 105 hair samples from suspected ET users. Of these, 50 tested positive for ET and 43 tested positive for ETA above the LOQ. This demonstrates the effectiveness of the developed UHPLC-MS/MS method in detecting ET and ETA in hair samples, which could be instrumental in addressing the issue of illegal E-cigarette abuse and its impact on public health.
期刊介绍:
The journal Forensic Toxicology provides an international forum for publication of studies on toxic substances, drugs of abuse, doping agents, chemical warfare agents, and their metabolisms and analyses, which are related to laws and ethics. It includes original articles, reviews, mini-reviews, short communications, and case reports. Although a major focus of the journal is on the development or improvement of analytical methods for the above-mentioned chemicals in human matrices, appropriate studies with animal experiments are also published.