Christopher M McGraw, Samvrit Rao, Shashank Manjunath, Jin Jing, M Brandon Westover
{"title":"自动量化人体脑电图中的周期性放电","authors":"Christopher M McGraw, Samvrit Rao, Shashank Manjunath, Jin Jing, M Brandon Westover","doi":"10.1088/2057-1976/ad6c53","DOIUrl":null,"url":null,"abstract":"<p><p>Periodic discharges (PDs) are pathologic patterns of epileptiform discharges repeating at regular intervals, commonly detected in the human electroencephalogram (EEG) signals in patients who are critically ill. The frequency and spatial extent of PDs are associated with the tendency of PDs to cause brain injury, existing automated algorithms do not quantify the frequency and spatial extent of PDs. The present study presents an algorithm for quantifying frequency and spatial extent of PDs. The algorithm quantifies the evolution of these parameters within a short (10-14 second) window, with a focus on lateralized and generalized periodic discharges. We test our algorithm on 300 'easy', 300 'medium', and 240 'hard' examples (840 total epochs) of periodic discharges as quantified by interrater consensus from human experts when analyzing the given EEG epochs. We observe 95.0% agreement with a 95% confidence interval (CI) of [94.9%, 95.1%] between algorithm outputs with reviewer clincal judgement for easy examples, 92.0% agreement (95% CI [91.9%, 92.2%]) for medium examples, and 90.4% agreement (95% CI [90.3%, 90.6%]) for hard examples. The algorithm is also computationally efficient and is able to run in 0.385 ± 0.038 seconds for a single epoch using our provided implementation of the algorithm. The results demonstrate the algorithm's effectiveness in quantifying these discharges and provide a standardized and efficient approach for PD quantification as compared to existing manual approaches.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11580140/pdf/","citationCount":"0","resultStr":"{\"title\":\"Automated quantification of periodic discharges in human electroencephalogram.\",\"authors\":\"Christopher M McGraw, Samvrit Rao, Shashank Manjunath, Jin Jing, M Brandon Westover\",\"doi\":\"10.1088/2057-1976/ad6c53\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Periodic discharges (PDs) are pathologic patterns of epileptiform discharges repeating at regular intervals, commonly detected in the human electroencephalogram (EEG) signals in patients who are critically ill. The frequency and spatial extent of PDs are associated with the tendency of PDs to cause brain injury, existing automated algorithms do not quantify the frequency and spatial extent of PDs. The present study presents an algorithm for quantifying frequency and spatial extent of PDs. The algorithm quantifies the evolution of these parameters within a short (10-14 second) window, with a focus on lateralized and generalized periodic discharges. We test our algorithm on 300 'easy', 300 'medium', and 240 'hard' examples (840 total epochs) of periodic discharges as quantified by interrater consensus from human experts when analyzing the given EEG epochs. We observe 95.0% agreement with a 95% confidence interval (CI) of [94.9%, 95.1%] between algorithm outputs with reviewer clincal judgement for easy examples, 92.0% agreement (95% CI [91.9%, 92.2%]) for medium examples, and 90.4% agreement (95% CI [90.3%, 90.6%]) for hard examples. The algorithm is also computationally efficient and is able to run in 0.385 ± 0.038 seconds for a single epoch using our provided implementation of the algorithm. The results demonstrate the algorithm's effectiveness in quantifying these discharges and provide a standardized and efficient approach for PD quantification as compared to existing manual approaches.</p>\",\"PeriodicalId\":8896,\"journal\":{\"name\":\"Biomedical Physics & Engineering Express\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11580140/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Physics & Engineering Express\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/2057-1976/ad6c53\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/ad6c53","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Automated quantification of periodic discharges in human electroencephalogram.
Periodic discharges (PDs) are pathologic patterns of epileptiform discharges repeating at regular intervals, commonly detected in the human electroencephalogram (EEG) signals in patients who are critically ill. The frequency and spatial extent of PDs are associated with the tendency of PDs to cause brain injury, existing automated algorithms do not quantify the frequency and spatial extent of PDs. The present study presents an algorithm for quantifying frequency and spatial extent of PDs. The algorithm quantifies the evolution of these parameters within a short (10-14 second) window, with a focus on lateralized and generalized periodic discharges. We test our algorithm on 300 'easy', 300 'medium', and 240 'hard' examples (840 total epochs) of periodic discharges as quantified by interrater consensus from human experts when analyzing the given EEG epochs. We observe 95.0% agreement with a 95% confidence interval (CI) of [94.9%, 95.1%] between algorithm outputs with reviewer clincal judgement for easy examples, 92.0% agreement (95% CI [91.9%, 92.2%]) for medium examples, and 90.4% agreement (95% CI [90.3%, 90.6%]) for hard examples. The algorithm is also computationally efficient and is able to run in 0.385 ± 0.038 seconds for a single epoch using our provided implementation of the algorithm. The results demonstrate the algorithm's effectiveness in quantifying these discharges and provide a standardized and efficient approach for PD quantification as compared to existing manual approaches.
期刊介绍:
BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.