优化成人脊柱畸形术前骨健康评估:日本椎弓根螺钉术中插入扭矩与成像模式的前瞻性关联分析。

IF 2.3 Q2 ORTHOPEDICS
Asian Spine Journal Pub Date : 2024-08-01 Epub Date: 2024-08-08 DOI:10.31616/asj.2023.0443
Keishi Maruo, Fumihiro Arizumi, Tomoyuki Kusukawa, Masakazu Toi, Masaru Hatano, Tetsuto Yamaura, Kazuya Kishima, Toshiya Tachibana
{"title":"优化成人脊柱畸形术前骨健康评估:日本椎弓根螺钉术中插入扭矩与成像模式的前瞻性关联分析。","authors":"Keishi Maruo, Fumihiro Arizumi, Tomoyuki Kusukawa, Masakazu Toi, Masaru Hatano, Tetsuto Yamaura, Kazuya Kishima, Toshiya Tachibana","doi":"10.31616/asj.2023.0443","DOIUrl":null,"url":null,"abstract":"<p><strong>Study design: </strong>Prospective cohort study.</p><p><strong>Purpose: </strong>This study aimed to identify the optimal preoperative bone health assessment for adult spinal deformity (ASD) surgery through correlation analysis between intraoperative pedicle screw (PS) insertion torque and various bone quality measures, including bone mineral density (BMD) assessed by dual-energy X-ray absorptiometry (DEXA), Hounsfield unit (HU) by computed tomography (CT), and vertebral bone quality (VBQ) score by magnetic resonance imaging.</p><p><strong>Overview of literature: </strong>Existing data on optimal assessment tools for ASD surgery are limited.</p><p><strong>Methods: </strong>The study included patients with ASD aged >60 years who underwent spinal corrective fusion surgery from the lower thoracic spine to the pelvis. The intraoperative PS insertion torque was measured using a torque meter. Pearson correlation coefficients were calculated between the PS insertion torque and the BMD, HU, and VBQ score. Preoperative bone quality was compared between the proximal junctional failure (PJF) and non-PJF groups.</p><p><strong>Results: </strong>Thirty-one patients with 177 PS at T10, T11, and T12 were analyzed. The PS insertion torque showed a moderate positive correlation with lumbar spine BMD (r=0.59-0.69, p<0.01), total hip BMD (0.58-0.62, p<0.01), and HU value (r=0.58-0.66, p<0.01). However, the VBQ score did not show significant correlation (r=-0.28 to -0.23, p >0.05). Notably, a strong correlation was found between the PS insertion torque and the HU value for screws of the same size (r=0.71 and 0.74, p<0.01). The HU value at T12 and the PS insertion torque at T10 were significantly lower in the PJF group than in the non-PJF group.</p><p><strong>Conclusions: </strong>This study demonstrates a positive correlation between the PS insertion torque and HU value in the lower thoracic spine and a moderate correlation with BMD but not the VBQ score. Preoperative assessment using DEXA and CT is crucial for optimizing bone health management in ASD surgery.</p>","PeriodicalId":8555,"journal":{"name":"Asian Spine Journal","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11366562/pdf/","citationCount":"0","resultStr":"{\"title\":\"Optimizing preoperative bone health assessment for adult spinal deformity: a prospective correlation analysis of intraoperative pedicle screw insertion torque and imaging modalities in Japan.\",\"authors\":\"Keishi Maruo, Fumihiro Arizumi, Tomoyuki Kusukawa, Masakazu Toi, Masaru Hatano, Tetsuto Yamaura, Kazuya Kishima, Toshiya Tachibana\",\"doi\":\"10.31616/asj.2023.0443\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Study design: </strong>Prospective cohort study.</p><p><strong>Purpose: </strong>This study aimed to identify the optimal preoperative bone health assessment for adult spinal deformity (ASD) surgery through correlation analysis between intraoperative pedicle screw (PS) insertion torque and various bone quality measures, including bone mineral density (BMD) assessed by dual-energy X-ray absorptiometry (DEXA), Hounsfield unit (HU) by computed tomography (CT), and vertebral bone quality (VBQ) score by magnetic resonance imaging.</p><p><strong>Overview of literature: </strong>Existing data on optimal assessment tools for ASD surgery are limited.</p><p><strong>Methods: </strong>The study included patients with ASD aged >60 years who underwent spinal corrective fusion surgery from the lower thoracic spine to the pelvis. The intraoperative PS insertion torque was measured using a torque meter. Pearson correlation coefficients were calculated between the PS insertion torque and the BMD, HU, and VBQ score. Preoperative bone quality was compared between the proximal junctional failure (PJF) and non-PJF groups.</p><p><strong>Results: </strong>Thirty-one patients with 177 PS at T10, T11, and T12 were analyzed. The PS insertion torque showed a moderate positive correlation with lumbar spine BMD (r=0.59-0.69, p<0.01), total hip BMD (0.58-0.62, p<0.01), and HU value (r=0.58-0.66, p<0.01). However, the VBQ score did not show significant correlation (r=-0.28 to -0.23, p >0.05). Notably, a strong correlation was found between the PS insertion torque and the HU value for screws of the same size (r=0.71 and 0.74, p<0.01). The HU value at T12 and the PS insertion torque at T10 were significantly lower in the PJF group than in the non-PJF group.</p><p><strong>Conclusions: </strong>This study demonstrates a positive correlation between the PS insertion torque and HU value in the lower thoracic spine and a moderate correlation with BMD but not the VBQ score. Preoperative assessment using DEXA and CT is crucial for optimizing bone health management in ASD surgery.</p>\",\"PeriodicalId\":8555,\"journal\":{\"name\":\"Asian Spine Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11366562/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Spine Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31616/asj.2023.0443\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Spine Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31616/asj.2023.0443","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/8 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

研究设计:前瞻性队列研究:目的:本研究旨在通过分析术中椎弓根螺钉(PS)插入扭矩与各种骨质量指标之间的相关性,确定成人脊柱畸形(ASD)手术的最佳术前骨健康评估方法,这些指标包括双能X射线吸收测量法(DEXA)评估的骨矿物质密度(BMD)、计算机断层扫描(CT)的霍恩斯菲尔德单位(HU)以及磁共振成像的椎体骨质量(VBQ)评分:有关 ASD 手术最佳评估工具的现有数据有限:研究对象包括年龄大于60岁、接受下胸椎至骨盆脊柱矫正融合手术的ASD患者。使用扭矩仪测量术中 PS 插入扭矩。计算了 PS 插入扭矩与 BMD、HU 和 VBQ 评分之间的皮尔逊相关系数。比较了近端连接失败(PJF)组与非 PJF 组的术前骨质情况:结果:分析了 31 名在 T10、T11 和 T12 位置有 177 个 PS 的患者。PS 插入扭矩与腰椎 BMD 呈中度正相关(r=0.59-0.69,p0.05)。值得注意的是,相同尺寸螺钉的 PS 插入扭矩与 HU 值之间存在很强的相关性(r=0.71 和 0.74,p 结论:本研究表明,下胸椎的 PS 插入扭矩和 HU 值之间存在正相关,与 BMD 存在中度相关,但与 VBQ 评分无关。使用 DEXA 和 CT 进行术前评估对于优化 ASD 手术中的骨健康管理至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimizing preoperative bone health assessment for adult spinal deformity: a prospective correlation analysis of intraoperative pedicle screw insertion torque and imaging modalities in Japan.

Study design: Prospective cohort study.

Purpose: This study aimed to identify the optimal preoperative bone health assessment for adult spinal deformity (ASD) surgery through correlation analysis between intraoperative pedicle screw (PS) insertion torque and various bone quality measures, including bone mineral density (BMD) assessed by dual-energy X-ray absorptiometry (DEXA), Hounsfield unit (HU) by computed tomography (CT), and vertebral bone quality (VBQ) score by magnetic resonance imaging.

Overview of literature: Existing data on optimal assessment tools for ASD surgery are limited.

Methods: The study included patients with ASD aged >60 years who underwent spinal corrective fusion surgery from the lower thoracic spine to the pelvis. The intraoperative PS insertion torque was measured using a torque meter. Pearson correlation coefficients were calculated between the PS insertion torque and the BMD, HU, and VBQ score. Preoperative bone quality was compared between the proximal junctional failure (PJF) and non-PJF groups.

Results: Thirty-one patients with 177 PS at T10, T11, and T12 were analyzed. The PS insertion torque showed a moderate positive correlation with lumbar spine BMD (r=0.59-0.69, p<0.01), total hip BMD (0.58-0.62, p<0.01), and HU value (r=0.58-0.66, p<0.01). However, the VBQ score did not show significant correlation (r=-0.28 to -0.23, p >0.05). Notably, a strong correlation was found between the PS insertion torque and the HU value for screws of the same size (r=0.71 and 0.74, p<0.01). The HU value at T12 and the PS insertion torque at T10 were significantly lower in the PJF group than in the non-PJF group.

Conclusions: This study demonstrates a positive correlation between the PS insertion torque and HU value in the lower thoracic spine and a moderate correlation with BMD but not the VBQ score. Preoperative assessment using DEXA and CT is crucial for optimizing bone health management in ASD surgery.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Asian Spine Journal
Asian Spine Journal ORTHOPEDICS-
CiteScore
5.10
自引率
4.30%
发文量
108
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信