与开放式方法相比,利用机器人平台结合实时吲哚青绿荧光胆管造影术进行成人右移植活体肝移植的疗效。

IF 7.5 1区 医学 Q1 SURGERY
Annals of surgery Pub Date : 2024-11-01 Epub Date: 2024-08-07 DOI:10.1097/SLA.0000000000006477
Dimitri A Raptis, Yogesh K Vashist, Rugved Kulkarni, Saleh Alabbad, Yasser Elsheikh, Yasir Alnemary, Massimo Malagò, Dieter C Broering
{"title":"与开放式方法相比,利用机器人平台结合实时吲哚青绿荧光胆管造影术进行成人右移植活体肝移植的疗效。","authors":"Dimitri A Raptis, Yogesh K Vashist, Rugved Kulkarni, Saleh Alabbad, Yasser Elsheikh, Yasir Alnemary, Massimo Malagò, Dieter C Broering","doi":"10.1097/SLA.0000000000006477","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to assess short-term biliary outcomes in adult living donor liver transplants using right grafts, comparing robotic surgery with real-time indocyanine green fluorescence cholangiography for optimal hilar plate transection, against the conventional open approach.</p><p><strong>Background: </strong>Determining the optimal transection plane through the hilar plate is crucial in donor hepatectomies, impacting outcomes significantly.</p><p><strong>Methods: </strong>From 2011 to 2023, a total of 839 right graft living donor hepatectomies were performed, with 414 (49%) performed via the open approach and 425 (51%) utilizing the robotic platform.</p><p><strong>Results: </strong>The magnetic resonant cholangiopancreatography predictions correlated moderately with the actual count of graft ducts ( r =0.57, P <0.001). Out of all 839 right donor hepatectomies, 321 (44%) were single duct grafts, of which 193/425 (49%) were retrieved with the robotic while 128/414 (38%) were with the open approach (OR: 1.58, 95% CI: 1.16-2.14), P =0.003). Overall, 50 (6%) of the donors developed a biliary complication during their hospital stay, of whom 38 (9%) were grafts retrieved with the open, while 13 (3%) with the robotic approach (OR: 0.31, 95% CI: 0.15-0.61, P <0.001). Similarly, 63 (15%) of the adult recipients developed a biliary complication of any severity when grafts were retrieved with the open approach compared to 35 (8%) with the robotic approach (OR: 0.50, 95% CI: 0.31-0.79), P =0.002).</p><p><strong>Conclusions: </strong>The robotic platform with integrated real-time indocyanine green fluorescence cholangiography during right donor hepatectomy offers improved safety for the donor by accurately addressing the right hilar corridor, resulting in fewer graft ducts and fewer complications for the donor and recipient when compared to the standard open approach.</p>","PeriodicalId":8017,"journal":{"name":"Annals of surgery","volume":null,"pages":null},"PeriodicalIF":7.5000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Outcomes of Adult Right Graft Living Donor Liver Transplantation Utilizing the Robotic Platform-integrated Real-time Indocyanine Green Fluorescence Cholangiography Compared to the Open Approach.\",\"authors\":\"Dimitri A Raptis, Yogesh K Vashist, Rugved Kulkarni, Saleh Alabbad, Yasser Elsheikh, Yasir Alnemary, Massimo Malagò, Dieter C Broering\",\"doi\":\"10.1097/SLA.0000000000006477\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>This study aimed to assess short-term biliary outcomes in adult living donor liver transplants using right grafts, comparing robotic surgery with real-time indocyanine green fluorescence cholangiography for optimal hilar plate transection, against the conventional open approach.</p><p><strong>Background: </strong>Determining the optimal transection plane through the hilar plate is crucial in donor hepatectomies, impacting outcomes significantly.</p><p><strong>Methods: </strong>From 2011 to 2023, a total of 839 right graft living donor hepatectomies were performed, with 414 (49%) performed via the open approach and 425 (51%) utilizing the robotic platform.</p><p><strong>Results: </strong>The magnetic resonant cholangiopancreatography predictions correlated moderately with the actual count of graft ducts ( r =0.57, P <0.001). Out of all 839 right donor hepatectomies, 321 (44%) were single duct grafts, of which 193/425 (49%) were retrieved with the robotic while 128/414 (38%) were with the open approach (OR: 1.58, 95% CI: 1.16-2.14), P =0.003). Overall, 50 (6%) of the donors developed a biliary complication during their hospital stay, of whom 38 (9%) were grafts retrieved with the open, while 13 (3%) with the robotic approach (OR: 0.31, 95% CI: 0.15-0.61, P <0.001). Similarly, 63 (15%) of the adult recipients developed a biliary complication of any severity when grafts were retrieved with the open approach compared to 35 (8%) with the robotic approach (OR: 0.50, 95% CI: 0.31-0.79), P =0.002).</p><p><strong>Conclusions: </strong>The robotic platform with integrated real-time indocyanine green fluorescence cholangiography during right donor hepatectomy offers improved safety for the donor by accurately addressing the right hilar corridor, resulting in fewer graft ducts and fewer complications for the donor and recipient when compared to the standard open approach.</p>\",\"PeriodicalId\":8017,\"journal\":{\"name\":\"Annals of surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":7.5000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/SLA.0000000000006477\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/SLA.0000000000006477","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/7 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在评估使用右侧移植物进行成人活体肝移植的短期胆道预后,比较机器人手术与传统开放式方法,前者采用实时吲哚青绿荧光胆管造影术(ICG-CA)进行最佳肝门板横切:在供体肝切除术中,确定通过肝门板的最佳横切平面至关重要,会对手术效果产生重大影响:从2011年到2023年,共进行了839例右移植活体供体肝切除术,其中414例(49%)采用开放式方法,425例(51%)采用机器人平台:结果:MRCP预测结果与移植物导管的实际数量呈中度相关(r=0.57):与标准开放式方法相比,在右供体肝切除术中使用集成实时 ICG-CA 的机器人平台可准确处理右肝走廊,从而提高供体的安全性,减少移植物导管,减少供体和受体的并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Outcomes of Adult Right Graft Living Donor Liver Transplantation Utilizing the Robotic Platform-integrated Real-time Indocyanine Green Fluorescence Cholangiography Compared to the Open Approach.

Objective: This study aimed to assess short-term biliary outcomes in adult living donor liver transplants using right grafts, comparing robotic surgery with real-time indocyanine green fluorescence cholangiography for optimal hilar plate transection, against the conventional open approach.

Background: Determining the optimal transection plane through the hilar plate is crucial in donor hepatectomies, impacting outcomes significantly.

Methods: From 2011 to 2023, a total of 839 right graft living donor hepatectomies were performed, with 414 (49%) performed via the open approach and 425 (51%) utilizing the robotic platform.

Results: The magnetic resonant cholangiopancreatography predictions correlated moderately with the actual count of graft ducts ( r =0.57, P <0.001). Out of all 839 right donor hepatectomies, 321 (44%) were single duct grafts, of which 193/425 (49%) were retrieved with the robotic while 128/414 (38%) were with the open approach (OR: 1.58, 95% CI: 1.16-2.14), P =0.003). Overall, 50 (6%) of the donors developed a biliary complication during their hospital stay, of whom 38 (9%) were grafts retrieved with the open, while 13 (3%) with the robotic approach (OR: 0.31, 95% CI: 0.15-0.61, P <0.001). Similarly, 63 (15%) of the adult recipients developed a biliary complication of any severity when grafts were retrieved with the open approach compared to 35 (8%) with the robotic approach (OR: 0.50, 95% CI: 0.31-0.79), P =0.002).

Conclusions: The robotic platform with integrated real-time indocyanine green fluorescence cholangiography during right donor hepatectomy offers improved safety for the donor by accurately addressing the right hilar corridor, resulting in fewer graft ducts and fewer complications for the donor and recipient when compared to the standard open approach.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Annals of surgery
Annals of surgery 医学-外科
CiteScore
14.40
自引率
4.40%
发文量
687
审稿时长
4 months
期刊介绍: The Annals of Surgery is a renowned surgery journal, recognized globally for its extensive scholarly references. It serves as a valuable resource for the international medical community by disseminating knowledge regarding important developments in surgical science and practice. Surgeons regularly turn to the Annals of Surgery to stay updated on innovative practices and techniques. The journal also offers special editorial features such as "Advances in Surgical Technique," offering timely coverage of ongoing clinical issues. Additionally, the journal publishes monthly review articles that address the latest concerns in surgical practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信