高/低比和有效容积对优化高炉炉型的耦合效应的数值研究

Junjie Li, Lulu Jiao, Shibo Kuang, Ruiping Zou, Wenqi Zhong, Aibing Yu
{"title":"高/低比和有效容积对优化高炉炉型的耦合效应的数值研究","authors":"Junjie Li, Lulu Jiao, Shibo Kuang, Ruiping Zou, Wenqi Zhong, Aibing Yu","doi":"10.1007/s11663-024-03218-8","DOIUrl":null,"url":null,"abstract":"<p>The design and optimization of blast furnace (BF) profiles generally rely on limited empirical knowledge and experience. Such exercise can now be improved by means of process modeling and optimization. In this work, the effect of furnace profile on BF performance is numerically investigated across a wide range of furnace volumes (500 to 6000 m<sup>3</sup>), focusing on the ratio of effective height to belly diameter (<i>H</i>/<i>D</i> ratio). This is done based on the recently developed 3D multi-fluid BF process model. The results indicate that the optimized <i>H</i>/<i>D</i> ratio under different furnace volumes can be determined by minimizing the total energy consumption, namely, the summation of chemical and physical energy consumptions. Comparative analysis indicates that the industrial data on the variation of <i>H</i>/<i>D</i> ratio with furnace volume, collected over years, can be reproduced quantitatively by the current model. The increase in BF size or volume results in high thermal energy efficiency and low coke rate, primarily attributed to the reduced heat dissipation from the top gas and furnace wall. But there exists a size threshold between small and large BFs, approximately 2000 m<sup>3</sup> under the conditions considered. Beyond this threshold, the BF performance and in-furnace states do not change significantly. Optimum BF profile needs to consider the coupled effect of <i>H</i>/<i>D</i> ratio and effective furnace volume.</p>","PeriodicalId":18613,"journal":{"name":"Metallurgical and Materials Transactions B","volume":"26 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Numerical Investigation of the Coupled Effect of H/D Ratio and Effective Volume on Optimized Blast Furnace Profile\",\"authors\":\"Junjie Li, Lulu Jiao, Shibo Kuang, Ruiping Zou, Wenqi Zhong, Aibing Yu\",\"doi\":\"10.1007/s11663-024-03218-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The design and optimization of blast furnace (BF) profiles generally rely on limited empirical knowledge and experience. Such exercise can now be improved by means of process modeling and optimization. In this work, the effect of furnace profile on BF performance is numerically investigated across a wide range of furnace volumes (500 to 6000 m<sup>3</sup>), focusing on the ratio of effective height to belly diameter (<i>H</i>/<i>D</i> ratio). This is done based on the recently developed 3D multi-fluid BF process model. The results indicate that the optimized <i>H</i>/<i>D</i> ratio under different furnace volumes can be determined by minimizing the total energy consumption, namely, the summation of chemical and physical energy consumptions. Comparative analysis indicates that the industrial data on the variation of <i>H</i>/<i>D</i> ratio with furnace volume, collected over years, can be reproduced quantitatively by the current model. The increase in BF size or volume results in high thermal energy efficiency and low coke rate, primarily attributed to the reduced heat dissipation from the top gas and furnace wall. But there exists a size threshold between small and large BFs, approximately 2000 m<sup>3</sup> under the conditions considered. Beyond this threshold, the BF performance and in-furnace states do not change significantly. Optimum BF profile needs to consider the coupled effect of <i>H</i>/<i>D</i> ratio and effective furnace volume.</p>\",\"PeriodicalId\":18613,\"journal\":{\"name\":\"Metallurgical and Materials Transactions B\",\"volume\":\"26 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-08-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metallurgical and Materials Transactions B\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s11663-024-03218-8\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metallurgical and Materials Transactions B","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s11663-024-03218-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

高炉(BF)炉型的设计和优化通常依赖于有限的经验知识和经验。现在可以通过工艺建模和优化来改进这种做法。在这项工作中,我们对高炉炉型对高炉性能的影响进行了数值研究,研究范围涵盖高炉容积(500 至 6000 立方米),重点关注有效高度与炉腹直径之比(H/D 比)。这项研究是基于最近开发的三维多流体 BF 工艺模型进行的。结果表明,在不同炉子容积下的优化 H/D 比可以通过最小化总能耗来确定,即化学能耗和物理能耗的总和。对比分析表明,目前的模型可以定量再现多年来收集的有关 H/D 比率随炉容积变化的工业数据。BF 尺寸或体积的增加会导致热能效率高和焦炭率低,这主要归因于炉顶煤气和炉壁的散热量减少。但在小型和大型 BF 之间存在一个尺寸阈值,在考虑的条件下约为 2000 立方米。超过这个临界值后,BF 的性能和炉内状态不会发生显著变化。最佳 BF 曲线需要考虑 H/D 比和有效炉体积的耦合效应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Numerical Investigation of the Coupled Effect of H/D Ratio and Effective Volume on Optimized Blast Furnace Profile

Numerical Investigation of the Coupled Effect of H/D Ratio and Effective Volume on Optimized Blast Furnace Profile

The design and optimization of blast furnace (BF) profiles generally rely on limited empirical knowledge and experience. Such exercise can now be improved by means of process modeling and optimization. In this work, the effect of furnace profile on BF performance is numerically investigated across a wide range of furnace volumes (500 to 6000 m3), focusing on the ratio of effective height to belly diameter (H/D ratio). This is done based on the recently developed 3D multi-fluid BF process model. The results indicate that the optimized H/D ratio under different furnace volumes can be determined by minimizing the total energy consumption, namely, the summation of chemical and physical energy consumptions. Comparative analysis indicates that the industrial data on the variation of H/D ratio with furnace volume, collected over years, can be reproduced quantitatively by the current model. The increase in BF size or volume results in high thermal energy efficiency and low coke rate, primarily attributed to the reduced heat dissipation from the top gas and furnace wall. But there exists a size threshold between small and large BFs, approximately 2000 m3 under the conditions considered. Beyond this threshold, the BF performance and in-furnace states do not change significantly. Optimum BF profile needs to consider the coupled effect of H/D ratio and effective furnace volume.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信