{"title":"在胃肠道手术镇静和镇痛过程中用于早期检测呼吸衰竭的连续式气管造影。","authors":"Stacey C Tobin","doi":"10.1097/SGA.0000000000000839","DOIUrl":null,"url":null,"abstract":"<p><p>Gastroenterology nurses working across a variety of clinical settings are responsible for periprocedural monitoring during moderate to deep procedural sedation and analgesia (PSA) to identify signs of respiratory compromise and intervene to prevent cardiorespiratory events. Pulse oximetry is the standard of care for respiratory monitoring, but it may delay or fail to detect abnormal ventilation during PSA. Continuous capnography, which measures end-tidal CO2 as a marker of alveolar ventilation, has been endorsed by a number of clinical guidelines. Large clinical trials have demonstrated that the addition of continuous capnography to pulse oximetry during PSA for various gastroenterological procedures reduces the incidence of hypoxemia, severe hypoxemia, and apnea. Studies have shown that the cost of adding continuous capnography is offset by the reduction in adverse events and hospital length of stay. In the postanesthesia care unit, continuous capnography is being evaluated for monitoring opioid-induced respiratory depression and to guide artificial airway removal. Studies are also examining the utility of continuous capnography to predict the risk of opioid-induced respiratory depression among patients receiving opioids for primary analgesia. Continuous capnography monitoring has become an essential tool to detect early signs of respiratory compromise in patients receiving PSA during gastroenterological procedures. When combined with pulse oximetry, it can help reduce cardiorespiratory adverse events, improve patient outcomes and safety, and reduce health care costs.</p>","PeriodicalId":12666,"journal":{"name":"Gastroenterology Nursing","volume":"47 4","pages":"291-298"},"PeriodicalIF":0.7000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Continuous Capnography for Early Detection of Respiratory Compromise During Gastroenterological Procedural Sedation and Analgesia.\",\"authors\":\"Stacey C Tobin\",\"doi\":\"10.1097/SGA.0000000000000839\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Gastroenterology nurses working across a variety of clinical settings are responsible for periprocedural monitoring during moderate to deep procedural sedation and analgesia (PSA) to identify signs of respiratory compromise and intervene to prevent cardiorespiratory events. Pulse oximetry is the standard of care for respiratory monitoring, but it may delay or fail to detect abnormal ventilation during PSA. Continuous capnography, which measures end-tidal CO2 as a marker of alveolar ventilation, has been endorsed by a number of clinical guidelines. Large clinical trials have demonstrated that the addition of continuous capnography to pulse oximetry during PSA for various gastroenterological procedures reduces the incidence of hypoxemia, severe hypoxemia, and apnea. Studies have shown that the cost of adding continuous capnography is offset by the reduction in adverse events and hospital length of stay. In the postanesthesia care unit, continuous capnography is being evaluated for monitoring opioid-induced respiratory depression and to guide artificial airway removal. Studies are also examining the utility of continuous capnography to predict the risk of opioid-induced respiratory depression among patients receiving opioids for primary analgesia. Continuous capnography monitoring has become an essential tool to detect early signs of respiratory compromise in patients receiving PSA during gastroenterological procedures. When combined with pulse oximetry, it can help reduce cardiorespiratory adverse events, improve patient outcomes and safety, and reduce health care costs.</p>\",\"PeriodicalId\":12666,\"journal\":{\"name\":\"Gastroenterology Nursing\",\"volume\":\"47 4\",\"pages\":\"291-298\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Gastroenterology Nursing\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/SGA.0000000000000839\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gastroenterology Nursing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/SGA.0000000000000839","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/28 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
Continuous Capnography for Early Detection of Respiratory Compromise During Gastroenterological Procedural Sedation and Analgesia.
Gastroenterology nurses working across a variety of clinical settings are responsible for periprocedural monitoring during moderate to deep procedural sedation and analgesia (PSA) to identify signs of respiratory compromise and intervene to prevent cardiorespiratory events. Pulse oximetry is the standard of care for respiratory monitoring, but it may delay or fail to detect abnormal ventilation during PSA. Continuous capnography, which measures end-tidal CO2 as a marker of alveolar ventilation, has been endorsed by a number of clinical guidelines. Large clinical trials have demonstrated that the addition of continuous capnography to pulse oximetry during PSA for various gastroenterological procedures reduces the incidence of hypoxemia, severe hypoxemia, and apnea. Studies have shown that the cost of adding continuous capnography is offset by the reduction in adverse events and hospital length of stay. In the postanesthesia care unit, continuous capnography is being evaluated for monitoring opioid-induced respiratory depression and to guide artificial airway removal. Studies are also examining the utility of continuous capnography to predict the risk of opioid-induced respiratory depression among patients receiving opioids for primary analgesia. Continuous capnography monitoring has become an essential tool to detect early signs of respiratory compromise in patients receiving PSA during gastroenterological procedures. When combined with pulse oximetry, it can help reduce cardiorespiratory adverse events, improve patient outcomes and safety, and reduce health care costs.
期刊介绍:
Gastroenterology Nursing: The Official Leader in Science and Practice delivers the information nurses need to stay ahead in this specialty. The journal keeps gastroenterology nurses and associates informed of the latest developments in research, evidence-based practice techniques, equipment, diagnostics, and therapy. The only professional, peer-reviewed nursing journal covering this area, Gastroenterology Nursing is an invaluable resource for current SGNA guidelines, new GI procedures, pharmacology, career development, and certification review. Its lively editorial style and illustrations make the journal a pleasure to read and consult.
Official Journal of the Society of Gastroenterology Nurses and Associates and Canadian Society of Gastroenterology Nurses and Associates