Joanna Abraham, Christopher R King, Lavanya Pedamallu, Mallory Light, Bernadette Henrichs
{"title":"标准化电子病历集成交接报告对术中交流结果的影响。","authors":"Joanna Abraham, Christopher R King, Lavanya Pedamallu, Mallory Light, Bernadette Henrichs","doi":"10.1093/jamia/ocae204","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>We evaluated the effectiveness and implementability of a standardized EHR-integrated handoff report to support intraoperative handoffs.</p><p><strong>Materials and methods: </strong>A pre-post intervention study was used to compare the quality of intraoperative handoffs supported by unstructured notes (pre) to structured, standardized EHR-integrated handoff reports (post). Participants included anesthesia clinicians involved in intraoperative handoffs. A mixed-method approach was followed, supported by general observations, shadowing, surveys, and interviews.</p><p><strong>Results: </strong>One hundred and fifty-one intraoperative permanent handoffs (78 pre, 73 post) were included. One hundred percent of participants in the post-intervention cohort utilized the report. Compared to unstructured, structured handoffs using the EHR-integrated handoff report led to: (1) significant increase in the transfer of information about airway management (55%-78%, P < .001), intraoperative course (63%-86%, P < .001), and potential concerns (64%-88%, P < .001); (2) significant improvement in clinician satisfaction scores, with regards to information clarity and succinctness (4.5-4.7, P = .002), information transfer (3.8-4.2, P = .011), and opportunities for fewer errors reported by senders (3.3-2.5, P < .001) and receivers (3.2-2.4, P < .001); and (3) significant decrease in handoff duration (326.2-262.3 s, P = .016). Clinicians found the report implementation highly acceptable, appropriate, and feasible but noted a few areas for improvement to enhance its usability and integration within the intraoperative workflow.</p><p><strong>Discussion and conclusion: </strong>A standardized EHR-integrated handoff report ensures the effectiveness and efficiency of intraoperative handoffs with its structured, consistent format that-promotes up-to-date and pertinent intraoperative information transfer; reduces opportunities for errors; and streamlines verbal communication. Handoff standardization can promote safe and high-quality intraoperative care.</p>","PeriodicalId":50016,"journal":{"name":"Journal of the American Medical Informatics Association","volume":null,"pages":null},"PeriodicalIF":4.7000,"publicationDate":"2024-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of standardized EHR-integrated handoff report on intraoperative communication outcomes.\",\"authors\":\"Joanna Abraham, Christopher R King, Lavanya Pedamallu, Mallory Light, Bernadette Henrichs\",\"doi\":\"10.1093/jamia/ocae204\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>We evaluated the effectiveness and implementability of a standardized EHR-integrated handoff report to support intraoperative handoffs.</p><p><strong>Materials and methods: </strong>A pre-post intervention study was used to compare the quality of intraoperative handoffs supported by unstructured notes (pre) to structured, standardized EHR-integrated handoff reports (post). Participants included anesthesia clinicians involved in intraoperative handoffs. A mixed-method approach was followed, supported by general observations, shadowing, surveys, and interviews.</p><p><strong>Results: </strong>One hundred and fifty-one intraoperative permanent handoffs (78 pre, 73 post) were included. One hundred percent of participants in the post-intervention cohort utilized the report. Compared to unstructured, structured handoffs using the EHR-integrated handoff report led to: (1) significant increase in the transfer of information about airway management (55%-78%, P < .001), intraoperative course (63%-86%, P < .001), and potential concerns (64%-88%, P < .001); (2) significant improvement in clinician satisfaction scores, with regards to information clarity and succinctness (4.5-4.7, P = .002), information transfer (3.8-4.2, P = .011), and opportunities for fewer errors reported by senders (3.3-2.5, P < .001) and receivers (3.2-2.4, P < .001); and (3) significant decrease in handoff duration (326.2-262.3 s, P = .016). Clinicians found the report implementation highly acceptable, appropriate, and feasible but noted a few areas for improvement to enhance its usability and integration within the intraoperative workflow.</p><p><strong>Discussion and conclusion: </strong>A standardized EHR-integrated handoff report ensures the effectiveness and efficiency of intraoperative handoffs with its structured, consistent format that-promotes up-to-date and pertinent intraoperative information transfer; reduces opportunities for errors; and streamlines verbal communication. Handoff standardization can promote safe and high-quality intraoperative care.</p>\",\"PeriodicalId\":50016,\"journal\":{\"name\":\"Journal of the American Medical Informatics Association\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2024-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Medical Informatics Association\",\"FirstCategoryId\":\"91\",\"ListUrlMain\":\"https://doi.org/10.1093/jamia/ocae204\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"COMPUTER SCIENCE, INFORMATION SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Medical Informatics Association","FirstCategoryId":"91","ListUrlMain":"https://doi.org/10.1093/jamia/ocae204","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"COMPUTER SCIENCE, INFORMATION SYSTEMS","Score":null,"Total":0}
Effect of standardized EHR-integrated handoff report on intraoperative communication outcomes.
Objectives: We evaluated the effectiveness and implementability of a standardized EHR-integrated handoff report to support intraoperative handoffs.
Materials and methods: A pre-post intervention study was used to compare the quality of intraoperative handoffs supported by unstructured notes (pre) to structured, standardized EHR-integrated handoff reports (post). Participants included anesthesia clinicians involved in intraoperative handoffs. A mixed-method approach was followed, supported by general observations, shadowing, surveys, and interviews.
Results: One hundred and fifty-one intraoperative permanent handoffs (78 pre, 73 post) were included. One hundred percent of participants in the post-intervention cohort utilized the report. Compared to unstructured, structured handoffs using the EHR-integrated handoff report led to: (1) significant increase in the transfer of information about airway management (55%-78%, P < .001), intraoperative course (63%-86%, P < .001), and potential concerns (64%-88%, P < .001); (2) significant improvement in clinician satisfaction scores, with regards to information clarity and succinctness (4.5-4.7, P = .002), information transfer (3.8-4.2, P = .011), and opportunities for fewer errors reported by senders (3.3-2.5, P < .001) and receivers (3.2-2.4, P < .001); and (3) significant decrease in handoff duration (326.2-262.3 s, P = .016). Clinicians found the report implementation highly acceptable, appropriate, and feasible but noted a few areas for improvement to enhance its usability and integration within the intraoperative workflow.
Discussion and conclusion: A standardized EHR-integrated handoff report ensures the effectiveness and efficiency of intraoperative handoffs with its structured, consistent format that-promotes up-to-date and pertinent intraoperative information transfer; reduces opportunities for errors; and streamlines verbal communication. Handoff standardization can promote safe and high-quality intraoperative care.
期刊介绍:
JAMIA is AMIA''s premier peer-reviewed journal for biomedical and health informatics. Covering the full spectrum of activities in the field, JAMIA includes informatics articles in the areas of clinical care, clinical research, translational science, implementation science, imaging, education, consumer health, public health, and policy. JAMIA''s articles describe innovative informatics research and systems that help to advance biomedical science and to promote health. Case reports, perspectives and reviews also help readers stay connected with the most important informatics developments in implementation, policy and education.