基于剂量组学的前列腺癌螺旋断层治疗剂量分布变化检测:治疗方案参数的影响。

IF 2.4 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Marziyeh Mirzaeiyan, Ali Akhavan, Simin Hemati, Mahnaz Etehadtavakol, Alireza Amouheidari, Atoosa Adibi, Hossein Khanahmad, Zahra Sharifonnasabi, Parvaneh Shokrani
{"title":"基于剂量组学的前列腺癌螺旋断层治疗剂量分布变化检测:治疗方案参数的影响。","authors":"Marziyeh Mirzaeiyan, Ali Akhavan, Simin Hemati, Mahnaz Etehadtavakol, Alireza Amouheidari, Atoosa Adibi, Hossein Khanahmad, Zahra Sharifonnasabi, Parvaneh Shokrani","doi":"10.1007/s13246-024-01463-4","DOIUrl":null,"url":null,"abstract":"<p><p>The stability of dosiomics features (DFs) and dose-volume histogram (DVH) parameters for detecting disparities in helical tomotherapy planned dose distributions was assessed. Treatment plans of 18 prostate patients were recalculated using the followings: field width (WF) (2.5 vs. 5), pitch factor (PF) (0.433 vs. 0.444), and modulation factor (MF) (2.5 vs. 3). From each of the eight plans per patient, ninety-three original and 744 wavelet-based DFs were extracted, using 3D-Slicer software, across six regions including: target volume (PTV), pelvic lymph nodes (PTV-LN), PTV + PTV-LN (PTV-All), one cm rind around PTV-All (PTV-Ring), rectum, and bladder. For the resulting DFs and DVH parameters, the coefficient of variation (CV) was calculated, and using hierarchical clustering, the features were classified into low/high variability. The significance of parameters on instability was analyzed by a three-way analysis of variance. All DF's were stable in PTV, PTV-LN, and PTV-Ring (average CV ( <math> <mrow> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> <mrow><mo>)</mo></mrow> </mrow> </math>  ≤ 0.36). Only one feature in the bladder ( <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math>  = 0.9), rectum ( <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math>  = 0.4), and PTV-All ( <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math>  = 0.37) were considered unstable due to change in MF in the bladder and WF in the PTV-All. The value of <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math> for the wavelet features was much higher than that for the original features. Out of 225 unstable wavelet features, 84 features had <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math>  ≥ 1. The CVs for all the DVHs remained very small ( <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math> < 0.06). This study highlights that the sensitivity of DFs to changes in tomotherapy planning parameters is influenced by the region and the DFs, particularly wavelet features, surpassing the effectiveness of DVHs.</p>","PeriodicalId":48490,"journal":{"name":"Physical and Engineering Sciences in Medicine","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dosiomics-based detection of dose distribution variations in helical tomotherapy for prostate cancer patients: influence of treatment plan parameters.\",\"authors\":\"Marziyeh Mirzaeiyan, Ali Akhavan, Simin Hemati, Mahnaz Etehadtavakol, Alireza Amouheidari, Atoosa Adibi, Hossein Khanahmad, Zahra Sharifonnasabi, Parvaneh Shokrani\",\"doi\":\"10.1007/s13246-024-01463-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The stability of dosiomics features (DFs) and dose-volume histogram (DVH) parameters for detecting disparities in helical tomotherapy planned dose distributions was assessed. Treatment plans of 18 prostate patients were recalculated using the followings: field width (WF) (2.5 vs. 5), pitch factor (PF) (0.433 vs. 0.444), and modulation factor (MF) (2.5 vs. 3). From each of the eight plans per patient, ninety-three original and 744 wavelet-based DFs were extracted, using 3D-Slicer software, across six regions including: target volume (PTV), pelvic lymph nodes (PTV-LN), PTV + PTV-LN (PTV-All), one cm rind around PTV-All (PTV-Ring), rectum, and bladder. For the resulting DFs and DVH parameters, the coefficient of variation (CV) was calculated, and using hierarchical clustering, the features were classified into low/high variability. The significance of parameters on instability was analyzed by a three-way analysis of variance. All DF's were stable in PTV, PTV-LN, and PTV-Ring (average CV ( <math> <mrow> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> <mrow><mo>)</mo></mrow> </mrow> </math>  ≤ 0.36). Only one feature in the bladder ( <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math>  = 0.9), rectum ( <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math>  = 0.4), and PTV-All ( <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math>  = 0.37) were considered unstable due to change in MF in the bladder and WF in the PTV-All. The value of <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math> for the wavelet features was much higher than that for the original features. Out of 225 unstable wavelet features, 84 features had <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math>  ≥ 1. The CVs for all the DVHs remained very small ( <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math> < 0.06). This study highlights that the sensitivity of DFs to changes in tomotherapy planning parameters is influenced by the region and the DFs, particularly wavelet features, surpassing the effectiveness of DVHs.</p>\",\"PeriodicalId\":48490,\"journal\":{\"name\":\"Physical and Engineering Sciences in Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2024-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physical and Engineering Sciences in Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s13246-024-01463-4\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical and Engineering Sciences in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s13246-024-01463-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

我们评估了用于检测螺旋断层治疗计划剂量分布差异的剂量组学特征(DFs)和剂量-体积直方图(DVH)参数的稳定性。对 18 位前列腺患者的治疗计划进行了重新计算,计算时使用了以下参数:场宽 (WF) (2.5 vs. 5)、间距因子 (PF) (0.433 vs. 0.444) 和调制因子 (MF) (2.5 vs. 3)。使用 3D-Slicer 软件从每名患者的八份计划中提取了 93 个原始 DF 和 744 个基于小波的 DF,涉及六个区域,包括:靶体积 (PTV)、盆腔淋巴结 (PTV-LN)、PTV + PTV-LN (PTV-All)、PTV-All 周围一厘米边缘 (PTV-Ring)、直肠和膀胱。对于得出的 DFs 和 DVH 参数,计算变异系数 (CV),并使用层次聚类将特征分为低变异性/高变异性。参数对不稳定性的影响通过三方方差分析进行分析。在 PTV、PTV-LN 和 PTV-Ring 中,所有 DF 都是稳定的(平均 CV ( CV ¯ ) ≤ 0.36)。只有膀胱(CV ¯ = 0.9)、直肠(CV ¯ = 0.4)和 PTV-All (CV ¯ = 0.37)中的一个特征被认为是不稳定的,原因是膀胱中频和 PTV-All 中的 WF 发生了变化。小波特征的 CV ¯ 值远远高于原始特征的 CV ¯ 值。在 225 个不稳定的小波特征中,有 84 个特征的 CV ¯ ≥ 1。所有 DVH 的 CV 值都非常小(CV ¯ ≥ 1)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Dosiomics-based detection of dose distribution variations in helical tomotherapy for prostate cancer patients: influence of treatment plan parameters.

Dosiomics-based detection of dose distribution variations in helical tomotherapy for prostate cancer patients: influence of treatment plan parameters.

The stability of dosiomics features (DFs) and dose-volume histogram (DVH) parameters for detecting disparities in helical tomotherapy planned dose distributions was assessed. Treatment plans of 18 prostate patients were recalculated using the followings: field width (WF) (2.5 vs. 5), pitch factor (PF) (0.433 vs. 0.444), and modulation factor (MF) (2.5 vs. 3). From each of the eight plans per patient, ninety-three original and 744 wavelet-based DFs were extracted, using 3D-Slicer software, across six regions including: target volume (PTV), pelvic lymph nodes (PTV-LN), PTV + PTV-LN (PTV-All), one cm rind around PTV-All (PTV-Ring), rectum, and bladder. For the resulting DFs and DVH parameters, the coefficient of variation (CV) was calculated, and using hierarchical clustering, the features were classified into low/high variability. The significance of parameters on instability was analyzed by a three-way analysis of variance. All DF's were stable in PTV, PTV-LN, and PTV-Ring (average CV ( CV ¯ )  ≤ 0.36). Only one feature in the bladder ( CV ¯  = 0.9), rectum ( CV ¯  = 0.4), and PTV-All ( CV ¯  = 0.37) were considered unstable due to change in MF in the bladder and WF in the PTV-All. The value of CV ¯ for the wavelet features was much higher than that for the original features. Out of 225 unstable wavelet features, 84 features had CV ¯  ≥ 1. The CVs for all the DVHs remained very small ( CV ¯ < 0.06). This study highlights that the sensitivity of DFs to changes in tomotherapy planning parameters is influenced by the region and the DFs, particularly wavelet features, surpassing the effectiveness of DVHs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.40
自引率
4.50%
发文量
110
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信