Simona Marianna Sanzani, P. Catalano, Gianluca Tanucci, F. Giametta, B. Bianchi
{"title":"用于食品消毒的新型电解水电池发生器原型的设计建造和能耗研究","authors":"Simona Marianna Sanzani, P. Catalano, Gianluca Tanucci, F. Giametta, B. Bianchi","doi":"10.3390/sci6030043","DOIUrl":null,"url":null,"abstract":"This study explores the feasibility of producing electrolyzed water (EW) for post-harvest treatment of fruits and vegetables as a new substitute for current chemical products. A prototype generator using tap water and NaCl solution was tested for EW’s sanitization efficiency, energy, and economic costs. In vitro tests on Penicillium e., Aspergillus n., Botrytis c., and Alternaria a. assessed EW pH, chlorine concentration, electro-oxidative potential, pathogen contact time, and energy consumption. Optimal results were achieved with a pH of 4.6, electro-oxidative potential of 188 mV, active chlorine concentration of 3.4 mg/L, and a contact time of 1–2 min. The prototype produced 10.0 L of EW in 1 h, consuming 0.11 kWh of electricity. Real-scale energy consumption was 545 kWh/m3 EW, costing 12.51 euro/m3. The study concludes that optimizing EW production can reduce energy consumption, making it a viable alternative for industrial sanitization of fruits and vegetables.","PeriodicalId":510703,"journal":{"name":"Sci","volume":"109 34","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and Construction and Energy Consumption Study of a New Electrolyzed Water Cell Generator Prototype for Food Disinfection\",\"authors\":\"Simona Marianna Sanzani, P. Catalano, Gianluca Tanucci, F. Giametta, B. Bianchi\",\"doi\":\"10.3390/sci6030043\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study explores the feasibility of producing electrolyzed water (EW) for post-harvest treatment of fruits and vegetables as a new substitute for current chemical products. A prototype generator using tap water and NaCl solution was tested for EW’s sanitization efficiency, energy, and economic costs. In vitro tests on Penicillium e., Aspergillus n., Botrytis c., and Alternaria a. assessed EW pH, chlorine concentration, electro-oxidative potential, pathogen contact time, and energy consumption. Optimal results were achieved with a pH of 4.6, electro-oxidative potential of 188 mV, active chlorine concentration of 3.4 mg/L, and a contact time of 1–2 min. The prototype produced 10.0 L of EW in 1 h, consuming 0.11 kWh of electricity. Real-scale energy consumption was 545 kWh/m3 EW, costing 12.51 euro/m3. The study concludes that optimizing EW production can reduce energy consumption, making it a viable alternative for industrial sanitization of fruits and vegetables.\",\"PeriodicalId\":510703,\"journal\":{\"name\":\"Sci\",\"volume\":\"109 34\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sci\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/sci6030043\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sci","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/sci6030043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design and Construction and Energy Consumption Study of a New Electrolyzed Water Cell Generator Prototype for Food Disinfection
This study explores the feasibility of producing electrolyzed water (EW) for post-harvest treatment of fruits and vegetables as a new substitute for current chemical products. A prototype generator using tap water and NaCl solution was tested for EW’s sanitization efficiency, energy, and economic costs. In vitro tests on Penicillium e., Aspergillus n., Botrytis c., and Alternaria a. assessed EW pH, chlorine concentration, electro-oxidative potential, pathogen contact time, and energy consumption. Optimal results were achieved with a pH of 4.6, electro-oxidative potential of 188 mV, active chlorine concentration of 3.4 mg/L, and a contact time of 1–2 min. The prototype produced 10.0 L of EW in 1 h, consuming 0.11 kWh of electricity. Real-scale energy consumption was 545 kWh/m3 EW, costing 12.51 euro/m3. The study concludes that optimizing EW production can reduce energy consumption, making it a viable alternative for industrial sanitization of fruits and vegetables.