高流量梯度下熔盐接收器面板中的流量分布

Christian Schwager, Jonas Schulte, Matthias Binder, C. T. Teixeira Boura, Ulf Herrmann
{"title":"高流量梯度下熔盐接收器面板中的流量分布","authors":"Christian Schwager, Jonas Schulte, Matthias Binder, C. T. Teixeira Boura, Ulf Herrmann","doi":"10.52825/solarpaces.v2i.821","DOIUrl":null,"url":null,"abstract":"This paper presents a simulation study on critical mass flow distributions in receiver panels of commercial-scale molten salt towers (MST). Despite sophisticated aimpoint optimizations, the flux density distribution on an MST receiver in actual operation contains significant vertical and horizontal gradients. This study investigated how the latter affects the mass flow distribution among the parallel absorber tubes in each panel. A parametric study applied a discretized dynamic thermohydraulic model of a commercial scale receiver design, highlighting at which mass flow rates, flux density gradients and mean flux densities the flow distribution can become critical. Excessive temperature developments were observed, suggesting maintaining appropriate minimal mass flow rates to avoid damaging tube walls and the molten salt chemistry.","PeriodicalId":506238,"journal":{"name":"SolarPACES Conference Proceedings","volume":"17 12","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Flow Distribution in Molten Salt Receiver Panels at High Flux Gradients\",\"authors\":\"Christian Schwager, Jonas Schulte, Matthias Binder, C. T. Teixeira Boura, Ulf Herrmann\",\"doi\":\"10.52825/solarpaces.v2i.821\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a simulation study on critical mass flow distributions in receiver panels of commercial-scale molten salt towers (MST). Despite sophisticated aimpoint optimizations, the flux density distribution on an MST receiver in actual operation contains significant vertical and horizontal gradients. This study investigated how the latter affects the mass flow distribution among the parallel absorber tubes in each panel. A parametric study applied a discretized dynamic thermohydraulic model of a commercial scale receiver design, highlighting at which mass flow rates, flux density gradients and mean flux densities the flow distribution can become critical. Excessive temperature developments were observed, suggesting maintaining appropriate minimal mass flow rates to avoid damaging tube walls and the molten salt chemistry.\",\"PeriodicalId\":506238,\"journal\":{\"name\":\"SolarPACES Conference Proceedings\",\"volume\":\"17 12\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SolarPACES Conference Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52825/solarpaces.v2i.821\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SolarPACES Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52825/solarpaces.v2i.821","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了对商业规模熔盐塔(MST)接收器面板中临界质量流分布的模拟研究。尽管进行了复杂的瞄准点优化,但在实际运行中,MST 接收器上的流量密度分布仍存在明显的垂直和水平梯度。本研究探讨了后者如何影响每个面板中平行吸收管之间的质量流分布。参数研究采用了商业规模接收器设计的离散动态热流体力学模型,强调了在什么情况下质量流量、流量密度梯度和平均流量密度分布会变得至关重要。观察到温度发展过快,建议保持适当的最小质量流量,以避免损坏管壁和熔盐化学性质。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Flow Distribution in Molten Salt Receiver Panels at High Flux Gradients
This paper presents a simulation study on critical mass flow distributions in receiver panels of commercial-scale molten salt towers (MST). Despite sophisticated aimpoint optimizations, the flux density distribution on an MST receiver in actual operation contains significant vertical and horizontal gradients. This study investigated how the latter affects the mass flow distribution among the parallel absorber tubes in each panel. A parametric study applied a discretized dynamic thermohydraulic model of a commercial scale receiver design, highlighting at which mass flow rates, flux density gradients and mean flux densities the flow distribution can become critical. Excessive temperature developments were observed, suggesting maintaining appropriate minimal mass flow rates to avoid damaging tube walls and the molten salt chemistry.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信