{"title":"尼日利亚电气/电子技术教育专业毕业生使用自动传感器探测和扑灭煤气厂火灾的情况","authors":"Ifeanyi Benedict Ohanu, Uzoma Stephen Egesimba","doi":"10.1177/01445987241266630","DOIUrl":null,"url":null,"abstract":"Software systems such as Proteus, Matlab, and an Arduino Uno programming software system, comprising an Infra-red flame sensor, a 5v Motor and other components like Buzzer, relay, light emitting diode, transistor, resistor and capacitors, were used in order to detect smoke, flame or fire and suppress it in a laboratory. The methodology of the system's design, as well as the operation of the system, were schematically highlighted. The control measures and maintenance strategies to be deployed for the smooth functioning of the system design were also discussed, wherever they are used. Solutions to checkmate fire disasters were proffered. The workings of the system are that when the sensor registers or turns zero (0), it means that there is no fire, flame or smoke to suppress, while when it turns to one (1), it indicates that there is smoke or fire to suppress. The process recorded 95% success.","PeriodicalId":11606,"journal":{"name":"Energy Exploration & Exploitation","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fire detection and suppression in gas-plants using automatic sensors among electrical/electronic technology education graduates in Nigeria\",\"authors\":\"Ifeanyi Benedict Ohanu, Uzoma Stephen Egesimba\",\"doi\":\"10.1177/01445987241266630\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Software systems such as Proteus, Matlab, and an Arduino Uno programming software system, comprising an Infra-red flame sensor, a 5v Motor and other components like Buzzer, relay, light emitting diode, transistor, resistor and capacitors, were used in order to detect smoke, flame or fire and suppress it in a laboratory. The methodology of the system's design, as well as the operation of the system, were schematically highlighted. The control measures and maintenance strategies to be deployed for the smooth functioning of the system design were also discussed, wherever they are used. Solutions to checkmate fire disasters were proffered. The workings of the system are that when the sensor registers or turns zero (0), it means that there is no fire, flame or smoke to suppress, while when it turns to one (1), it indicates that there is smoke or fire to suppress. The process recorded 95% success.\",\"PeriodicalId\":11606,\"journal\":{\"name\":\"Energy Exploration & Exploitation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-07-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy Exploration & Exploitation\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/01445987241266630\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Exploration & Exploitation","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/01445987241266630","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0
摘要
为了检测实验室中的烟雾、火焰或火灾并加以抑制,使用了 Proteus、Matlab 和 Arduino Uno 编程软件系统等软件系统,包括一个红外线火焰传感器、一个 5v 电机和蜂鸣器、继电器、发光二极管、晶体管、电阻器和电容器等其他组件。系统的设计方法以及系统的运行原理图都得到了强调。此外,还讨论了为使系统设计顺利运行而采取的控制措施和维护策略。还提出了防止火灾的解决方案。该系统的工作原理是,当传感器记录或变为零(0)时,表示没有火、火焰或烟雾需要扑灭;而当传感器变为一(1)时,表示有烟雾或火需要扑灭。这一过程的成功率为 95%。
Fire detection and suppression in gas-plants using automatic sensors among electrical/electronic technology education graduates in Nigeria
Software systems such as Proteus, Matlab, and an Arduino Uno programming software system, comprising an Infra-red flame sensor, a 5v Motor and other components like Buzzer, relay, light emitting diode, transistor, resistor and capacitors, were used in order to detect smoke, flame or fire and suppress it in a laboratory. The methodology of the system's design, as well as the operation of the system, were schematically highlighted. The control measures and maintenance strategies to be deployed for the smooth functioning of the system design were also discussed, wherever they are used. Solutions to checkmate fire disasters were proffered. The workings of the system are that when the sensor registers or turns zero (0), it means that there is no fire, flame or smoke to suppress, while when it turns to one (1), it indicates that there is smoke or fire to suppress. The process recorded 95% success.
期刊介绍:
Energy Exploration & Exploitation is a peer-reviewed, open access journal that provides up-to-date, informative reviews and original articles on important issues in the exploration, exploitation, use and economics of the world’s energy resources.