{"title":"基于深度学习的盆腔恶性肿瘤选择性淋巴结区域划分的高效应用","authors":"Feng Wen, Jie Zhou, Zhebin Chen, Meng Dou, Yu Yao, Xin Wang, Feng Xu, Yali Shen","doi":"10.1002/mp.17330","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>While there are established international consensuses on the delineation of pelvic lymph node regions (LNRs), significant inter- and intra-observer variabilities persist. Contouring these clinical target volumes for irradiation in pelvic malignancies is both time-consuming and labor-intensive.</p>\n </section>\n \n <section>\n \n <h3> Purpose</h3>\n \n <p>The purpose of this study was to develop a deep learning model of pelvic LNRs delineation for patients with pelvic cancers.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Planning computed tomography (CT) studies of 160 patients with pelvic primary malignancies (including rectal, prostate, and cervical cancer) were retrospectively collected and divided into training set (<i>n</i> = 120) and testing set (<i>n</i> = 40). Six pelvic LNRs, including abdominal presacral, pelvic presacral, internal iliac nodes, external iliac nodes, obturator nodes, and inguinal nodes were delineated by two radiation oncologists as ground truth (Gt) contours. The cascaded multi-heads U-net (CMU-net) was constructed based on the Gt contours from training cohort, which was subsequently verified in the testing cohort. The automatic delineation of six LNRs (Auto) was evaluated using dice similarity coefficient (DSC), average surface distance (ASD), 95th percentile Hausdorff distance (HD95), and a 7-point scale score.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>In the testing set, the DSC of six pelvic LNRs by CMU-net model varied from 0.851 to 0.942, ASD from 0.381 to 1.037 mm, and HD95 from 2.025 to 3.697 mm. No significant differences were founded in these three parameters between postoperative and preoperative cases. 95.9% and 96.2% of auto delineations by CMU-net model got a score of 1–3 by two expert radiation oncologists, respectively, meaning only minor edits needed.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The CMU-net was successfully developed for automated delineation of pelvic LNRs for pelvic malignancies radiotherapy with improved contouring efficiency and highly consistent, which might justify its implementation in radiotherapy work flow.</p>\n </section>\n </div>","PeriodicalId":18384,"journal":{"name":"Medical physics","volume":"51 10","pages":"7057-7066"},"PeriodicalIF":3.2000,"publicationDate":"2024-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Efficient application of deep learning-based elective lymph node regions delineation for pelvic malignancies\",\"authors\":\"Feng Wen, Jie Zhou, Zhebin Chen, Meng Dou, Yu Yao, Xin Wang, Feng Xu, Yali Shen\",\"doi\":\"10.1002/mp.17330\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>While there are established international consensuses on the delineation of pelvic lymph node regions (LNRs), significant inter- and intra-observer variabilities persist. Contouring these clinical target volumes for irradiation in pelvic malignancies is both time-consuming and labor-intensive.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Purpose</h3>\\n \\n <p>The purpose of this study was to develop a deep learning model of pelvic LNRs delineation for patients with pelvic cancers.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>Planning computed tomography (CT) studies of 160 patients with pelvic primary malignancies (including rectal, prostate, and cervical cancer) were retrospectively collected and divided into training set (<i>n</i> = 120) and testing set (<i>n</i> = 40). Six pelvic LNRs, including abdominal presacral, pelvic presacral, internal iliac nodes, external iliac nodes, obturator nodes, and inguinal nodes were delineated by two radiation oncologists as ground truth (Gt) contours. The cascaded multi-heads U-net (CMU-net) was constructed based on the Gt contours from training cohort, which was subsequently verified in the testing cohort. The automatic delineation of six LNRs (Auto) was evaluated using dice similarity coefficient (DSC), average surface distance (ASD), 95th percentile Hausdorff distance (HD95), and a 7-point scale score.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>In the testing set, the DSC of six pelvic LNRs by CMU-net model varied from 0.851 to 0.942, ASD from 0.381 to 1.037 mm, and HD95 from 2.025 to 3.697 mm. No significant differences were founded in these three parameters between postoperative and preoperative cases. 95.9% and 96.2% of auto delineations by CMU-net model got a score of 1–3 by two expert radiation oncologists, respectively, meaning only minor edits needed.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>The CMU-net was successfully developed for automated delineation of pelvic LNRs for pelvic malignancies radiotherapy with improved contouring efficiency and highly consistent, which might justify its implementation in radiotherapy work flow.</p>\\n </section>\\n </div>\",\"PeriodicalId\":18384,\"journal\":{\"name\":\"Medical physics\",\"volume\":\"51 10\",\"pages\":\"7057-7066\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical physics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/mp.17330\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/mp.17330","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Efficient application of deep learning-based elective lymph node regions delineation for pelvic malignancies
Background
While there are established international consensuses on the delineation of pelvic lymph node regions (LNRs), significant inter- and intra-observer variabilities persist. Contouring these clinical target volumes for irradiation in pelvic malignancies is both time-consuming and labor-intensive.
Purpose
The purpose of this study was to develop a deep learning model of pelvic LNRs delineation for patients with pelvic cancers.
Methods
Planning computed tomography (CT) studies of 160 patients with pelvic primary malignancies (including rectal, prostate, and cervical cancer) were retrospectively collected and divided into training set (n = 120) and testing set (n = 40). Six pelvic LNRs, including abdominal presacral, pelvic presacral, internal iliac nodes, external iliac nodes, obturator nodes, and inguinal nodes were delineated by two radiation oncologists as ground truth (Gt) contours. The cascaded multi-heads U-net (CMU-net) was constructed based on the Gt contours from training cohort, which was subsequently verified in the testing cohort. The automatic delineation of six LNRs (Auto) was evaluated using dice similarity coefficient (DSC), average surface distance (ASD), 95th percentile Hausdorff distance (HD95), and a 7-point scale score.
Results
In the testing set, the DSC of six pelvic LNRs by CMU-net model varied from 0.851 to 0.942, ASD from 0.381 to 1.037 mm, and HD95 from 2.025 to 3.697 mm. No significant differences were founded in these three parameters between postoperative and preoperative cases. 95.9% and 96.2% of auto delineations by CMU-net model got a score of 1–3 by two expert radiation oncologists, respectively, meaning only minor edits needed.
Conclusions
The CMU-net was successfully developed for automated delineation of pelvic LNRs for pelvic malignancies radiotherapy with improved contouring efficiency and highly consistent, which might justify its implementation in radiotherapy work flow.
期刊介绍:
Medical Physics publishes original, high impact physics, imaging science, and engineering research that advances patient diagnosis and therapy through contributions in 1) Basic science developments with high potential for clinical translation 2) Clinical applications of cutting edge engineering and physics innovations 3) Broadly applicable and innovative clinical physics developments
Medical Physics is a journal of global scope and reach. By publishing in Medical Physics your research will reach an international, multidisciplinary audience including practicing medical physicists as well as physics- and engineering based translational scientists. We work closely with authors of promising articles to improve their quality.