{"title":"隔热材料不会妨碍创伤 CT 扫描中的损伤评估。","authors":"Tomasz Sanak, Aleksandra Skowronek, Konrad Mendrala, Tomasz Darocha, Grzegorz Liszka, Robert Chrzan, Krzysztof Jerzy Woźniak, Grzegorz Staskiewicz, Paweł Podsiadło","doi":"10.1007/s10140-024-02272-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The use of thermal insulations reduces the risk of hypothermia, therefore decreases the risk of death in trauma victims. The aim of the study was to assess whether thermal insulations cause artifacts, which may hinder the diagnosis of injuries, and how the used thermo-systems alter the radiation dose in polytrauma computed tomography.</p><p><strong>Methods: </strong>Computed tomography scans were made using the road accident victim body wrapped consecutively with 7 different covers. 14 injury areas were listed and evaluated by 22 radiologists. The radiation dose was measured using a dosimeter placed on the victim in the abdominal area.</p><p><strong>Results: </strong>No significant artifacts in any of the tested covers were observed. The presence of few minor artifacts did not hinder the assessment of injuries. Certain materials increased (up to 19,1%) and some decreased (up to -30,3%) the absorbed radiation dose.</p><p><strong>Conclusions: </strong>Thermal insulation systems tested in this study do not cause significant artifacts hindering assessment of injuries in CT scans. Concern for artifacts and increased radiation dose should not be a reason to remove patients' thermal insulation during performing trauma CT-scanning.</p>","PeriodicalId":11623,"journal":{"name":"Emergency Radiology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermal insulation does not hamper assessment of injuries in trauma CT scans.\",\"authors\":\"Tomasz Sanak, Aleksandra Skowronek, Konrad Mendrala, Tomasz Darocha, Grzegorz Liszka, Robert Chrzan, Krzysztof Jerzy Woźniak, Grzegorz Staskiewicz, Paweł Podsiadło\",\"doi\":\"10.1007/s10140-024-02272-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The use of thermal insulations reduces the risk of hypothermia, therefore decreases the risk of death in trauma victims. The aim of the study was to assess whether thermal insulations cause artifacts, which may hinder the diagnosis of injuries, and how the used thermo-systems alter the radiation dose in polytrauma computed tomography.</p><p><strong>Methods: </strong>Computed tomography scans were made using the road accident victim body wrapped consecutively with 7 different covers. 14 injury areas were listed and evaluated by 22 radiologists. The radiation dose was measured using a dosimeter placed on the victim in the abdominal area.</p><p><strong>Results: </strong>No significant artifacts in any of the tested covers were observed. The presence of few minor artifacts did not hinder the assessment of injuries. Certain materials increased (up to 19,1%) and some decreased (up to -30,3%) the absorbed radiation dose.</p><p><strong>Conclusions: </strong>Thermal insulation systems tested in this study do not cause significant artifacts hindering assessment of injuries in CT scans. Concern for artifacts and increased radiation dose should not be a reason to remove patients' thermal insulation during performing trauma CT-scanning.</p>\",\"PeriodicalId\":11623,\"journal\":{\"name\":\"Emergency Radiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Emergency Radiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s10140-024-02272-8\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Emergency Radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10140-024-02272-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:使用隔热材料可降低体温过低的风险,从而降低创伤患者的死亡风险。本研究的目的是评估隔热材料是否会造成伪影,从而妨碍伤情诊断,以及所使用的隔热系统如何改变多创伤计算机断层扫描的辐射剂量:方法:使用连续包裹有 7 种不同覆盖物的交通事故受害者身体进行计算机断层扫描。22 名放射科医生对 14 个受伤部位进行了检查和评估。使用放置在伤者腹部的剂量计测量辐射剂量:结果:在所有测试的覆盖物中均未观察到明显的伪影。少数轻微伪影的存在并不妨碍对伤害的评估。某些材料增加了吸收的辐射剂量(达 19.1%),某些材料则减少了吸收的辐射剂量(达 -30.3%):本研究中测试的隔热系统不会造成明显的伪影,不会妨碍 CT 扫描中的损伤评估。对伪影和辐射剂量增加的担忧不应成为在进行创伤 CT 扫描时去除患者隔热材料的理由。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Thermal insulation does not hamper assessment of injuries in trauma CT scans.

Purpose: The use of thermal insulations reduces the risk of hypothermia, therefore decreases the risk of death in trauma victims. The aim of the study was to assess whether thermal insulations cause artifacts, which may hinder the diagnosis of injuries, and how the used thermo-systems alter the radiation dose in polytrauma computed tomography.

Methods: Computed tomography scans were made using the road accident victim body wrapped consecutively with 7 different covers. 14 injury areas were listed and evaluated by 22 radiologists. The radiation dose was measured using a dosimeter placed on the victim in the abdominal area.

Results: No significant artifacts in any of the tested covers were observed. The presence of few minor artifacts did not hinder the assessment of injuries. Certain materials increased (up to 19,1%) and some decreased (up to -30,3%) the absorbed radiation dose.

Conclusions: Thermal insulation systems tested in this study do not cause significant artifacts hindering assessment of injuries in CT scans. Concern for artifacts and increased radiation dose should not be a reason to remove patients' thermal insulation during performing trauma CT-scanning.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Emergency Radiology
Emergency Radiology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.60
自引率
4.50%
发文量
98
期刊介绍: To advance and improve the radiologic aspects of emergency careTo establish Emergency Radiology as an area of special interest in the field of diagnostic imagingTo improve methods of education in Emergency RadiologyTo provide, through formal meetings, a mechanism for presentation of scientific papers on various aspects of Emergency Radiology and continuing educationTo promote research in Emergency Radiology by clinical and basic science investigators, including residents and other traineesTo act as the resource body on Emergency Radiology for those interested in emergency patient care Members of the American Society of Emergency Radiology (ASER) receive the Emergency Radiology journal as a benefit of membership!
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信