Linru Xie, Chen Jiang, Shuai Han, Boyi Li, Chengcheng Liu, Dean Ta
{"title":"利用虚拟声源合成孔径与相移迁移对深层骨缺损进行超声波成像:模型研究","authors":"Linru Xie, Chen Jiang, Shuai Han, Boyi Li, Chengcheng Liu, Dean Ta","doi":"10.1177/01617346241265468","DOIUrl":null,"url":null,"abstract":"<p><p>Ultrasound imaging for bone is a difficult task in the field of medical ultrasound. Compared with other phase array techniques, the synthetic aperture (SA) has a better lateral resolution but a limited imaging depth due to the limited ultrasonic energy emitted by the single emitter in each transmission. In contrast, the virtual source (VS) synthetic aperture allows a simultaneous multi-element emission and could provide a higher ultrasonic incident energy in each transmission. Therefore, the VS might achieve a high imaging quality at a deeper depth for bone imaging than the traditional SA. In this study, we proposed the virtual source phase shift migration (VS-PSM) method to achieve ultrasonic imaging of the deeper bone defect featured in the multilayer structure. The proposed VS-PSM method was validated using standard soft tissue phantom and printed bone phantom with artificial defects. The image quality was evaluated in terms of contrast-to-noise ratios (CNR) and amplitudes of scatters and defects at different imaging depths. The results showed that the VS-PSM method could achieve a high imaging quality of the soft tissues with a significant improvement in the scattering amplitude and without a significant sacrifice of the lateral and axial resolution. The PSM was superior to the DAS in suppressing the background noise in the images. Compared with the traditional SA-PSM, the VS-PSM method could image deeper bone defects at different ultrasonic frequencies, with an average improvement of 50% in CNR. In conclusion, this study demonstrated that the proposed VS-PSM method could image deeper bone defects and might help the diagnosis of bone disease using ultrasonic imaging.</p>","PeriodicalId":49401,"journal":{"name":"Ultrasonic Imaging","volume":" ","pages":"295-311"},"PeriodicalIF":2.5000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultrasonic Imaging of Deeper Bone Defect Using Virtual Source Synthetic Aperture with Phased Shift Migration: A Phantom Study.\",\"authors\":\"Linru Xie, Chen Jiang, Shuai Han, Boyi Li, Chengcheng Liu, Dean Ta\",\"doi\":\"10.1177/01617346241265468\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Ultrasound imaging for bone is a difficult task in the field of medical ultrasound. Compared with other phase array techniques, the synthetic aperture (SA) has a better lateral resolution but a limited imaging depth due to the limited ultrasonic energy emitted by the single emitter in each transmission. In contrast, the virtual source (VS) synthetic aperture allows a simultaneous multi-element emission and could provide a higher ultrasonic incident energy in each transmission. Therefore, the VS might achieve a high imaging quality at a deeper depth for bone imaging than the traditional SA. In this study, we proposed the virtual source phase shift migration (VS-PSM) method to achieve ultrasonic imaging of the deeper bone defect featured in the multilayer structure. The proposed VS-PSM method was validated using standard soft tissue phantom and printed bone phantom with artificial defects. The image quality was evaluated in terms of contrast-to-noise ratios (CNR) and amplitudes of scatters and defects at different imaging depths. The results showed that the VS-PSM method could achieve a high imaging quality of the soft tissues with a significant improvement in the scattering amplitude and without a significant sacrifice of the lateral and axial resolution. The PSM was superior to the DAS in suppressing the background noise in the images. Compared with the traditional SA-PSM, the VS-PSM method could image deeper bone defects at different ultrasonic frequencies, with an average improvement of 50% in CNR. In conclusion, this study demonstrated that the proposed VS-PSM method could image deeper bone defects and might help the diagnosis of bone disease using ultrasonic imaging.</p>\",\"PeriodicalId\":49401,\"journal\":{\"name\":\"Ultrasonic Imaging\",\"volume\":\" \",\"pages\":\"295-311\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasonic Imaging\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/01617346241265468\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonic Imaging","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/01617346241265468","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/26 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
Ultrasonic Imaging of Deeper Bone Defect Using Virtual Source Synthetic Aperture with Phased Shift Migration: A Phantom Study.
Ultrasound imaging for bone is a difficult task in the field of medical ultrasound. Compared with other phase array techniques, the synthetic aperture (SA) has a better lateral resolution but a limited imaging depth due to the limited ultrasonic energy emitted by the single emitter in each transmission. In contrast, the virtual source (VS) synthetic aperture allows a simultaneous multi-element emission and could provide a higher ultrasonic incident energy in each transmission. Therefore, the VS might achieve a high imaging quality at a deeper depth for bone imaging than the traditional SA. In this study, we proposed the virtual source phase shift migration (VS-PSM) method to achieve ultrasonic imaging of the deeper bone defect featured in the multilayer structure. The proposed VS-PSM method was validated using standard soft tissue phantom and printed bone phantom with artificial defects. The image quality was evaluated in terms of contrast-to-noise ratios (CNR) and amplitudes of scatters and defects at different imaging depths. The results showed that the VS-PSM method could achieve a high imaging quality of the soft tissues with a significant improvement in the scattering amplitude and without a significant sacrifice of the lateral and axial resolution. The PSM was superior to the DAS in suppressing the background noise in the images. Compared with the traditional SA-PSM, the VS-PSM method could image deeper bone defects at different ultrasonic frequencies, with an average improvement of 50% in CNR. In conclusion, this study demonstrated that the proposed VS-PSM method could image deeper bone defects and might help the diagnosis of bone disease using ultrasonic imaging.
期刊介绍:
Ultrasonic Imaging provides rapid publication for original and exceptional papers concerned with the development and application of ultrasonic-imaging technology. Ultrasonic Imaging publishes articles in the following areas: theoretical and experimental aspects of advanced methods and instrumentation for imaging