使用新型弹道投掷装置进行专项力量训练后的等速峰值扭矩改善和肩部肌肉比率失衡纠正:随机对照试验。

IF 1.3 4区 医学 Q3 REHABILITATION
Journal of Sport Rehabilitation Pub Date : 2024-07-19 Print Date: 2024-08-01 DOI:10.1123/jsr.2023-0253
Brahim Agrebi, Wissem Dhahbi, Hatem Abidi, Sofien Kasmi, Narjes Houas, Mokhtar Chtara, Karim Chamari
{"title":"使用新型弹道投掷装置进行专项力量训练后的等速峰值扭矩改善和肩部肌肉比率失衡纠正:随机对照试验。","authors":"Brahim Agrebi, Wissem Dhahbi, Hatem Abidi, Sofien Kasmi, Narjes Houas, Mokhtar Chtara, Karim Chamari","doi":"10.1123/jsr.2023-0253","DOIUrl":null,"url":null,"abstract":"<p><strong>Context: </strong>The aim of this study was to investigate the effects of 8-week ballistic-strength-training program using a validated specific throwing device (ie, Arm/Shoulder Specific Strength Device), on isokinetic shoulders' rotation muscle-torques and ratios as well as range of motion in team handball players.</p><p><strong>Design: </strong>A repeated-measures experimental design with a randomized controlled trial was used.</p><p><strong>Methods: </strong>Twenty-six high-level competitive male U-19 team handball players were randomly assigned into training (TG, n = 15) and control (n = 11) groups. The TG undertook a twice a week for 8-week periodized throws program with an individually predetermined optimal load. The program incorporated shackled eccentric and concentric exercises using the Arm/Shoulder Specific Strength Device. Peak torques, functional, and conventional ratios for both arms at different angular velocities (60°·s-1, 180°·s-1, and 300°·s-1) were assessed over time and between groups, using an isokinetic dynamometer.</p><p><strong>Results: </strong>A significant improvement for TG (P < .01; d = 1.13 [moderate]; +20.2%) of the concentric peak torques for dominant arm in external rotation was observed at 300°·s-1. Significant (P < .05-.01) increases were also noted for nondominant arm at the 3 studied angular velocities. In addition, 300°·s-1 eccentric peak torques of the dominant arm and nondominant arm have significantly improved for both external and internal rotations (P < .05; d = .99 [moderate] and d = 1.21 [large]; +15.7% and + 17.9%, respectively) with small changes at the other angular assessed velocities. Posttraining, TG's dominant arm showed significant improvements (P < .05-.01) in functional and conventional ratios at all velocities. Notably, significant differences (P < .05-.01) were observed at 60°·s-1 and across all velocities when comparing the TG with the control group. TG showed significant increase for internal rotation and external rotation shoulder range of motions (P < .05; d = 1.22-1.27 [large]), +5.0% and +7.7%, respectively).</p><p><strong>Conclusions: </strong>The specific 8-week throwing training program on the Arm/Shoulder Specific Strength Device showed significant performance improvements in almost all assessed isokinetic concentric and eccentric peak torques as well as internal and external range of motion increase for both arms while ensuring rotator cuff torque ratios and shoulder mobility in team handball real sport-specific condition.</p>","PeriodicalId":50041,"journal":{"name":"Journal of Sport Rehabilitation","volume":" ","pages":"423-436"},"PeriodicalIF":1.3000,"publicationDate":"2024-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Isokinetic Peak Torque Improvement and Shoulder Muscle Ratios Imbalance Correction After Specific Strength Training on a New Ballistic Throwing Device: A Randomized Controlled Trial.\",\"authors\":\"Brahim Agrebi, Wissem Dhahbi, Hatem Abidi, Sofien Kasmi, Narjes Houas, Mokhtar Chtara, Karim Chamari\",\"doi\":\"10.1123/jsr.2023-0253\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Context: </strong>The aim of this study was to investigate the effects of 8-week ballistic-strength-training program using a validated specific throwing device (ie, Arm/Shoulder Specific Strength Device), on isokinetic shoulders' rotation muscle-torques and ratios as well as range of motion in team handball players.</p><p><strong>Design: </strong>A repeated-measures experimental design with a randomized controlled trial was used.</p><p><strong>Methods: </strong>Twenty-six high-level competitive male U-19 team handball players were randomly assigned into training (TG, n = 15) and control (n = 11) groups. The TG undertook a twice a week for 8-week periodized throws program with an individually predetermined optimal load. The program incorporated shackled eccentric and concentric exercises using the Arm/Shoulder Specific Strength Device. Peak torques, functional, and conventional ratios for both arms at different angular velocities (60°·s-1, 180°·s-1, and 300°·s-1) were assessed over time and between groups, using an isokinetic dynamometer.</p><p><strong>Results: </strong>A significant improvement for TG (P < .01; d = 1.13 [moderate]; +20.2%) of the concentric peak torques for dominant arm in external rotation was observed at 300°·s-1. Significant (P < .05-.01) increases were also noted for nondominant arm at the 3 studied angular velocities. In addition, 300°·s-1 eccentric peak torques of the dominant arm and nondominant arm have significantly improved for both external and internal rotations (P < .05; d = .99 [moderate] and d = 1.21 [large]; +15.7% and + 17.9%, respectively) with small changes at the other angular assessed velocities. Posttraining, TG's dominant arm showed significant improvements (P < .05-.01) in functional and conventional ratios at all velocities. Notably, significant differences (P < .05-.01) were observed at 60°·s-1 and across all velocities when comparing the TG with the control group. TG showed significant increase for internal rotation and external rotation shoulder range of motions (P < .05; d = 1.22-1.27 [large]), +5.0% and +7.7%, respectively).</p><p><strong>Conclusions: </strong>The specific 8-week throwing training program on the Arm/Shoulder Specific Strength Device showed significant performance improvements in almost all assessed isokinetic concentric and eccentric peak torques as well as internal and external range of motion increase for both arms while ensuring rotator cuff torque ratios and shoulder mobility in team handball real sport-specific condition.</p>\",\"PeriodicalId\":50041,\"journal\":{\"name\":\"Journal of Sport Rehabilitation\",\"volume\":\" \",\"pages\":\"423-436\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Sport Rehabilitation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1123/jsr.2023-0253\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/1 0:00:00\",\"PubModel\":\"Print\",\"JCR\":\"Q3\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sport Rehabilitation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1123/jsr.2023-0253","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/1 0:00:00","PubModel":"Print","JCR":"Q3","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

摘要

研究背景本研究的目的是通过使用经过验证的特定投掷装置(即手臂/肩部特定力量装置),研究为期8周的弹道力量训练计划对手球运动员肩部等速旋转肌肉力矩和比率以及运动范围的影响:方法:采用随机对照试验的重复测量实验设计:26 名高水平男子 U-19 手球运动员被随机分配到训练组(TG,n = 15)和对照组(n = 11)。训练组每周进行两次为期 8 周的周期性投掷训练,并根据个人情况预先确定最佳负荷。该计划包括使用手臂/肩部特定力量装置进行带镣偏心和同心练习。在不同角速度(60°-s-1、180°-s-1 和 300°-s-1)下,使用等速测力计评估两臂的峰值扭矩、功能和常规比率:在 300°-s-1 时,观察到 TG(P < .01;d = 1.13 [中度];+20.2%)外旋优势臂的同心峰值扭矩有明显改善。在研究的 3 个角速度下,非优势臂的同心峰值扭矩也有显著增加(P < .05-.01)。此外,外旋和内旋时,优势臂和非优势臂的 300°-s-1 偏心峰值扭矩均有显著提高(P < .05;d = .99 [中等] 和 d = 1.21 [较大];分别为 +15.7% 和 +17.9%),其他角度评估速度的变化较小。训练后,TG 的优势臂在所有速度下的功能比率和常规比率都有显著改善(P < .05-.01)。值得注意的是,在 60°-s-1 和所有速度下,TG 组与对照组相比均有明显差异(P < .05-.01)。TG组的肩关节内旋和外旋运动幅度明显增加(P < .05;d = 1.22-1.27 [大]),分别增加了5.0%和7.7%):在手臂/肩部专项力量设备上进行的为期 8 周的投掷训练计划显示,在手球团队的真实运动条件下,几乎所有评估的等速同心和偏心峰值扭矩以及双臂的内外活动范围都有了显著提高,同时还确保了肩袖扭矩比和肩部活动度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Isokinetic Peak Torque Improvement and Shoulder Muscle Ratios Imbalance Correction After Specific Strength Training on a New Ballistic Throwing Device: A Randomized Controlled Trial.

Context: The aim of this study was to investigate the effects of 8-week ballistic-strength-training program using a validated specific throwing device (ie, Arm/Shoulder Specific Strength Device), on isokinetic shoulders' rotation muscle-torques and ratios as well as range of motion in team handball players.

Design: A repeated-measures experimental design with a randomized controlled trial was used.

Methods: Twenty-six high-level competitive male U-19 team handball players were randomly assigned into training (TG, n = 15) and control (n = 11) groups. The TG undertook a twice a week for 8-week periodized throws program with an individually predetermined optimal load. The program incorporated shackled eccentric and concentric exercises using the Arm/Shoulder Specific Strength Device. Peak torques, functional, and conventional ratios for both arms at different angular velocities (60°·s-1, 180°·s-1, and 300°·s-1) were assessed over time and between groups, using an isokinetic dynamometer.

Results: A significant improvement for TG (P < .01; d = 1.13 [moderate]; +20.2%) of the concentric peak torques for dominant arm in external rotation was observed at 300°·s-1. Significant (P < .05-.01) increases were also noted for nondominant arm at the 3 studied angular velocities. In addition, 300°·s-1 eccentric peak torques of the dominant arm and nondominant arm have significantly improved for both external and internal rotations (P < .05; d = .99 [moderate] and d = 1.21 [large]; +15.7% and + 17.9%, respectively) with small changes at the other angular assessed velocities. Posttraining, TG's dominant arm showed significant improvements (P < .05-.01) in functional and conventional ratios at all velocities. Notably, significant differences (P < .05-.01) were observed at 60°·s-1 and across all velocities when comparing the TG with the control group. TG showed significant increase for internal rotation and external rotation shoulder range of motions (P < .05; d = 1.22-1.27 [large]), +5.0% and +7.7%, respectively).

Conclusions: The specific 8-week throwing training program on the Arm/Shoulder Specific Strength Device showed significant performance improvements in almost all assessed isokinetic concentric and eccentric peak torques as well as internal and external range of motion increase for both arms while ensuring rotator cuff torque ratios and shoulder mobility in team handball real sport-specific condition.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Sport Rehabilitation
Journal of Sport Rehabilitation 医学-康复医学
CiteScore
3.20
自引率
5.90%
发文量
143
审稿时长
>12 weeks
期刊介绍: The Journal of Sport Rehabilitation (JSR) is your source for the latest peer-reviewed research in the field of sport rehabilitation. All members of the sports-medicine team will benefit from the wealth of important information in each issue. JSR is completely devoted to the rehabilitation of sport and exercise injuries, regardless of the age, gender, sport ability, level of fitness, or health status of the participant. JSR publishes peer-reviewed original research, systematic reviews/meta-analyses, critically appraised topics (CATs), case studies/series, and technical reports that directly affect the management and rehabilitation of injuries incurred during sport-related activities, irrespective of the individual’s age, gender, sport ability, level of fitness, or health status. The journal is intended to provide an international, multidisciplinary forum to serve the needs of all members of the sports medicine team, including athletic trainers/therapists, sport physical therapists/physiotherapists, sports medicine physicians, and other health care and medical professionals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信