{"title":"地震作用下输水隧道衬砌结构的破坏规律研究","authors":"Zhenxuan Gao","doi":"10.9734/air/2024/v25i41099","DOIUrl":null,"url":null,"abstract":"Based on the concrete damage plasticity constitutive model (CDP model) of ABAQUS software, the dynamic response of high pressure internal water conveyance tunnel during earthquake is simulated, and the dynamic response and dynamic damage law of high internal water pressure water conveyance tunnel structure under surrounding rock grade, buried depth and seismic wave intensity are analyzed. The research shows that the surrounding rock grade is closely related to the dynamic response and damage characteristics of the lining structure of the water conveyance tunnel. The dynamic damage of the tunnel under grade Ⅲ surrounding rock is only 0.08, which is far less than 0.83 under grade Ⅳ surrounding rock. It can be considered that it will not cause great damage to grade Ⅲ surrounding rock under earthquake. The surrounding rock grade is better, which can provide more stable support and reduce the stress and vibration of the structure. If the tunnel is in the seismic zone, the buried depth can be used as one of the design control indexes in the tunnel design. The lining damage is mainly distributed at the top and upper arch waist of the tunnel. With the increase of the buried depth of the tunnel, the dynamic damage amount increases from 0.021 to 0.081, then to 0.085. the damage of the lining structure also increases. This may be because the deep buried tunnel is more constrained by the underground rock and soil layer, thereby reducing the transmission of seismic load. The change of seismic wave intensity can directly affect the damage characteristics of tunnel lining structure. The dynamic damage mainly occurs at the vault and arch waist, and the damage area expands from the vault and arch waist to the side wall and corner. The increase of seismic wave intensity will lead to dramatic changes in the stress of the structure, which will lead to more complex and serious damage.","PeriodicalId":91191,"journal":{"name":"Advances in research","volume":"14 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Lining Structure of Water Conveyance Tunnel under Earthquake Action Research on Damage Law\",\"authors\":\"Zhenxuan Gao\",\"doi\":\"10.9734/air/2024/v25i41099\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Based on the concrete damage plasticity constitutive model (CDP model) of ABAQUS software, the dynamic response of high pressure internal water conveyance tunnel during earthquake is simulated, and the dynamic response and dynamic damage law of high internal water pressure water conveyance tunnel structure under surrounding rock grade, buried depth and seismic wave intensity are analyzed. The research shows that the surrounding rock grade is closely related to the dynamic response and damage characteristics of the lining structure of the water conveyance tunnel. The dynamic damage of the tunnel under grade Ⅲ surrounding rock is only 0.08, which is far less than 0.83 under grade Ⅳ surrounding rock. It can be considered that it will not cause great damage to grade Ⅲ surrounding rock under earthquake. The surrounding rock grade is better, which can provide more stable support and reduce the stress and vibration of the structure. If the tunnel is in the seismic zone, the buried depth can be used as one of the design control indexes in the tunnel design. The lining damage is mainly distributed at the top and upper arch waist of the tunnel. With the increase of the buried depth of the tunnel, the dynamic damage amount increases from 0.021 to 0.081, then to 0.085. the damage of the lining structure also increases. This may be because the deep buried tunnel is more constrained by the underground rock and soil layer, thereby reducing the transmission of seismic load. The change of seismic wave intensity can directly affect the damage characteristics of tunnel lining structure. The dynamic damage mainly occurs at the vault and arch waist, and the damage area expands from the vault and arch waist to the side wall and corner. The increase of seismic wave intensity will lead to dramatic changes in the stress of the structure, which will lead to more complex and serious damage.\",\"PeriodicalId\":91191,\"journal\":{\"name\":\"Advances in research\",\"volume\":\"14 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.9734/air/2024/v25i41099\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/air/2024/v25i41099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

基于 ABAQUS 软件的混凝土损伤塑性组成模型(CDP 模型),模拟了地震时高压内输水隧洞的动力响应,分析了高压内输水隧洞结构在围岩等级、埋深和地震波强度作用下的动力响应和动力损伤规律。研究表明,围岩等级与输水隧洞衬砌结构的动力响应和破坏特征密切相关。隧洞在Ⅲ级围岩下的动力破坏仅为 0.08,远小于Ⅳ级围岩下的 0.83。可以认为在地震作用下不会对Ⅲ级围岩造成大的破坏。围岩等级较好,可以提供较稳定的支护,减少结构的应力和振动。如果隧道处于地震区,埋深可作为隧道设计的控制指标之一。衬砌破坏主要分布在隧道顶部和上拱腰部。随着隧道埋深的增加,动态破坏量从 0.021 增加到 0.081,再增加到 0.085,衬砌结构的破坏也随之增加。这可能是因为深埋隧道受到地下岩土层的约束较大,从而减小了地震荷载的传递。地震波强度的变化会直接影响隧道衬砌结构的破坏特征。动破坏主要发生在拱顶和拱腰,破坏范围由拱顶和拱腰向侧壁和转角扩展。地震波强度的增加会导致结构应力的急剧变化,从而导致更复杂、更严重的破坏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Lining Structure of Water Conveyance Tunnel under Earthquake Action Research on Damage Law
Based on the concrete damage plasticity constitutive model (CDP model) of ABAQUS software, the dynamic response of high pressure internal water conveyance tunnel during earthquake is simulated, and the dynamic response and dynamic damage law of high internal water pressure water conveyance tunnel structure under surrounding rock grade, buried depth and seismic wave intensity are analyzed. The research shows that the surrounding rock grade is closely related to the dynamic response and damage characteristics of the lining structure of the water conveyance tunnel. The dynamic damage of the tunnel under grade Ⅲ surrounding rock is only 0.08, which is far less than 0.83 under grade Ⅳ surrounding rock. It can be considered that it will not cause great damage to grade Ⅲ surrounding rock under earthquake. The surrounding rock grade is better, which can provide more stable support and reduce the stress and vibration of the structure. If the tunnel is in the seismic zone, the buried depth can be used as one of the design control indexes in the tunnel design. The lining damage is mainly distributed at the top and upper arch waist of the tunnel. With the increase of the buried depth of the tunnel, the dynamic damage amount increases from 0.021 to 0.081, then to 0.085. the damage of the lining structure also increases. This may be because the deep buried tunnel is more constrained by the underground rock and soil layer, thereby reducing the transmission of seismic load. The change of seismic wave intensity can directly affect the damage characteristics of tunnel lining structure. The dynamic damage mainly occurs at the vault and arch waist, and the damage area expands from the vault and arch waist to the side wall and corner. The increase of seismic wave intensity will lead to dramatic changes in the stress of the structure, which will lead to more complex and serious damage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信