肱骨近端骨折反向肩关节置换术中的肱骨远端骨折块愈合与肱骨干的骨骺压入配合

Q4 Medicine
Benjamin W. Szerlip DO , Matthew T. Glazier DO , Walter R. Smith MD , Mitzi S. Laughlin PhD , T. Bradley Edwards MD
{"title":"肱骨近端骨折反向肩关节置换术中的肱骨远端骨折块愈合与肱骨干的骨骺压入配合","authors":"Benjamin W. Szerlip DO ,&nbsp;Matthew T. Glazier DO ,&nbsp;Walter R. Smith MD ,&nbsp;Mitzi S. Laughlin PhD ,&nbsp;T. Bradley Edwards MD","doi":"10.1053/j.sart.2024.06.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Reverse shoulder arthroplasty (RSA) is a viable option for proximal humerus fractures (PHFs) in the elderly, and cemented humeral fixation is the standard of care. This study evaluates the influence of a diaphyseal press-fit stem with a 142° humeral inclination on tuberosity healing (TH) and functional outcome in RSA for PHF.</div></div><div><h3>Methods</h3><div>Twenty-three patients received an RSA for PHF by a single surgeon at one center over a 2-year period. The humeral stem design was intended for diaphyseal press fit with a 142° humeral inclination. The tuberosities were repaired for each patient with bone graft and a standard suture technique. Patients’ clinical and radiographic outcomes were collected with a minimum 12-month follow-up.</div></div><div><h3>Results</h3><div>Nineteen of 23 patients (83%), with a mean age of 75 + years, were available for follow-up at an average of 14 months. Radiographic analysis showed 68% of patients had evidence of TH. Grade 1 scapular notching was found in 32% of patients. There was no implant loosening or subsidence noted. Average range of motion was 163° ± 15° degrees of forward flexion, 113° ± 24° of abduction, internal rotation to the waist, and an average external rotation of 7 ± 1.5 as measured by the Constant-Murley score. The average American Shoulder and Elbow Surgeons score was 81.8, and the average Constant-Murley score was 67.9. While not significant, those with TH trended toward better clinical outcomes. There was a 0% revision rate.</div></div><div><h3>Conclusion</h3><div>A press-fit stem designed for diaphyseal fixation provides consistent reliable results in RSA for PHF. A high percentage of TH was appreciated with a 142° humeral inclination, neutral glenosphere construct, and a standardized bone grafting, suture technique. TH is associated with improved patient outcomes.</div></div>","PeriodicalId":39885,"journal":{"name":"Seminars in Arthroplasty","volume":"34 4","pages":"Pages 854-861"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Tuberosity healing in reverse shoulder arthroplasty for proximal humerus fractures with a diaphyseal press-fit humeral stem\",\"authors\":\"Benjamin W. Szerlip DO ,&nbsp;Matthew T. Glazier DO ,&nbsp;Walter R. Smith MD ,&nbsp;Mitzi S. Laughlin PhD ,&nbsp;T. Bradley Edwards MD\",\"doi\":\"10.1053/j.sart.2024.06.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>Reverse shoulder arthroplasty (RSA) is a viable option for proximal humerus fractures (PHFs) in the elderly, and cemented humeral fixation is the standard of care. This study evaluates the influence of a diaphyseal press-fit stem with a 142° humeral inclination on tuberosity healing (TH) and functional outcome in RSA for PHF.</div></div><div><h3>Methods</h3><div>Twenty-three patients received an RSA for PHF by a single surgeon at one center over a 2-year period. The humeral stem design was intended for diaphyseal press fit with a 142° humeral inclination. The tuberosities were repaired for each patient with bone graft and a standard suture technique. Patients’ clinical and radiographic outcomes were collected with a minimum 12-month follow-up.</div></div><div><h3>Results</h3><div>Nineteen of 23 patients (83%), with a mean age of 75 + years, were available for follow-up at an average of 14 months. Radiographic analysis showed 68% of patients had evidence of TH. Grade 1 scapular notching was found in 32% of patients. There was no implant loosening or subsidence noted. Average range of motion was 163° ± 15° degrees of forward flexion, 113° ± 24° of abduction, internal rotation to the waist, and an average external rotation of 7 ± 1.5 as measured by the Constant-Murley score. The average American Shoulder and Elbow Surgeons score was 81.8, and the average Constant-Murley score was 67.9. While not significant, those with TH trended toward better clinical outcomes. There was a 0% revision rate.</div></div><div><h3>Conclusion</h3><div>A press-fit stem designed for diaphyseal fixation provides consistent reliable results in RSA for PHF. A high percentage of TH was appreciated with a 142° humeral inclination, neutral glenosphere construct, and a standardized bone grafting, suture technique. TH is associated with improved patient outcomes.</div></div>\",\"PeriodicalId\":39885,\"journal\":{\"name\":\"Seminars in Arthroplasty\",\"volume\":\"34 4\",\"pages\":\"Pages 854-861\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Seminars in Arthroplasty\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1045452724000774\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminars in Arthroplasty","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1045452724000774","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景:反向肩关节置换术(RSA)是治疗老年人肱骨近端骨折(phf)的可行选择,骨水泥肱骨固定是标准的治疗方法。本研究评估了肱骨倾角为142°的骨干压合柄对肱骨骨骺结节愈合(TH)和RSA治疗PHF的功能结果的影响。方法在2年内,23例患者在同一中心接受同一位外科医生对PHF的RSA治疗。肱骨柄设计用于骨干压迫配合,肱骨倾角为142°。采用植骨和标准缝合技术对每个患者的结节进行修复。通过至少12个月的随访收集患者的临床和影像学结果。结果23例患者中有19例(83%)获得平均14个月的随访,平均年龄75岁以上。放射学分析显示68%的患者有TH的证据。32%的患者出现1级肩胛骨切迹。未见种植体松动或下沉。根据Constant-Murley评分,患者的平均活动范围为前屈163°±15°,外展113°±24°,内旋至腰部,平均外旋7±1.5度。美国肩肘外科医生的平均评分为81.8分,康斯坦特-莫雷评分为67.9分。虽然不显著,但那些有甲状腺激素的患者趋向于更好的临床结果。修正率为0%。结论设计用于骨干骺端固定的压合柄可提供一致可靠的RSA治疗PHF的结果。采用142°肱骨倾斜、中性盂内球构造和标准化植骨、缝合技术,观察高比例的TH。TH与患者预后改善有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Tuberosity healing in reverse shoulder arthroplasty for proximal humerus fractures with a diaphyseal press-fit humeral stem

Background

Reverse shoulder arthroplasty (RSA) is a viable option for proximal humerus fractures (PHFs) in the elderly, and cemented humeral fixation is the standard of care. This study evaluates the influence of a diaphyseal press-fit stem with a 142° humeral inclination on tuberosity healing (TH) and functional outcome in RSA for PHF.

Methods

Twenty-three patients received an RSA for PHF by a single surgeon at one center over a 2-year period. The humeral stem design was intended for diaphyseal press fit with a 142° humeral inclination. The tuberosities were repaired for each patient with bone graft and a standard suture technique. Patients’ clinical and radiographic outcomes were collected with a minimum 12-month follow-up.

Results

Nineteen of 23 patients (83%), with a mean age of 75 + years, were available for follow-up at an average of 14 months. Radiographic analysis showed 68% of patients had evidence of TH. Grade 1 scapular notching was found in 32% of patients. There was no implant loosening or subsidence noted. Average range of motion was 163° ± 15° degrees of forward flexion, 113° ± 24° of abduction, internal rotation to the waist, and an average external rotation of 7 ± 1.5 as measured by the Constant-Murley score. The average American Shoulder and Elbow Surgeons score was 81.8, and the average Constant-Murley score was 67.9. While not significant, those with TH trended toward better clinical outcomes. There was a 0% revision rate.

Conclusion

A press-fit stem designed for diaphyseal fixation provides consistent reliable results in RSA for PHF. A high percentage of TH was appreciated with a 142° humeral inclination, neutral glenosphere construct, and a standardized bone grafting, suture technique. TH is associated with improved patient outcomes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Seminars in Arthroplasty
Seminars in Arthroplasty Medicine-Surgery
CiteScore
1.00
自引率
0.00%
发文量
104
期刊介绍: Each issue of Seminars in Arthroplasty provides a comprehensive, current overview of a single topic in arthroplasty. The journal addresses orthopedic surgeons, providing authoritative reviews with emphasis on new developments relevant to their practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信